- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT04987684
Mesures objectives de la position et de la fonction des électrodes de l'implant cochléaire
Recruit adult patients eligible for cochlear Implant surgery. During routine surgery monitor electrode placement with new 'SCINSEV' technique and complete 'PECAPs' on patient to identify if any of the electrodes have misplaced.
Follow up with patient after surgery for post operative appointment with same measurements.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Cochlear implants (CIs) restore hearing to deaf patients by electrically stimulating the auditory nerve using an array of electrodes inserted into the cochlea (inner ear). All electrodes should be successfully inserted in the cochlea, with each electrode exciting a discrete range of auditory nerve fibers.
Our research investigates two exceptions to this ideal situation, both of which impair the participant's ability to clearly hear sounds such as speech. One exception occurs when some electrodes are located outside the cochlea, limiting the amount of information that is conveyed to the brain and potentially causing unwanted side effects.
Our research will identify these extra-cochlear electrodes during the CI operation, by stimulating each electrode in turn and recording from all other electrodes.
This "SCINSEV" technique then uses a sophisticated computational method to identify which if any electrodes are out of the cochlea. Even when all electrodes are in the cochlea, however, some may produce broad current spreads, which will "blur" the perception of sounds. Our second "PECAP" method measures these instances by stimulating pairs of electrodes and recording the neural responses. It also uses a new computational method, this time so as to calculate the neural spread from each electrode.
Both methods use fast, non-invasive, objective measurements that use the built-in capabilities of the implant .The interventions used are very similar to those employed in standard clinical practice, and the results will pave the way for better identification and management of poor hearing by CI patients
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Cambridge, Royaume-Uni, CB2 OQQ
- Cambridge University Hospitals NHS Foundation Trust
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Participant is willing or able to consent to participation in the study
- Meets normal candidacy requirements for cochlear implantation
- At least 18 years of age at time of consent being given
- Patent cochlea as verified by CT or MRI scan
- No additional complex needs that would prevent study procedures being followed
- Agreement to participate in the study
Exclusion Criteria:
- Using medication in a manner that might affect hearing levels
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Soins de soutien
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Norme de soins
|
To measure PECAP and SCINSEVs. To find whether electrodes are outside of the cochlear or within dead regions within the cochlear. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Validation of extra cochlear electrodes
Délai: 12 months
|
Number of extra-cochlear electrodes obtained using our "SCINSEV" analysis correspond to the actual number of extra-cochlear electrodes observed during different stages of insertion. |
12 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Pre and post op loudness comparison
Délai: 12 months
|
Numbers of neural dead regions and wide current spread estimated intra-operatively and using equal current per electrode using our "PECAP" method correspond to those occurring post-operatively and using equal loudness per electrode |
12 months
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Les enquêteurs
- Chercheur principal: Daniele Borsetto, Addenbrookes Hospital, CUH
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- 285894
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .