Évaluation de l'utilisation du moniteur de glucose en continu chez les patients mal desservis en soins primaires

9 novembre 2026 mis à jour par: University of Nebraska

Continuous glucose monitoring (CGM) has demonstrated improved outcomes in both type 1 and type 2 diabetes populations in comparison to traditional methods; however, these devices have not been well studied in underserved adult patients (e.g., low-income, uninsured) who may face additional barriers to monitoring. Furthermore, there is limited data exploring long-term (3- to 6- month) health care team-based management of these devices in the primary care setting. The purpose of this study is to further understand the benefits and barriers associated with CGM use in underserved populations with type 2 diabetes and improve their overall diabetes care.

Aperçu de l'étude

Description détaillée

Continuous glucose monitoring (CGM) has demonstrated improved outcomes in both type 1 and type 2 diabetes populations in comparison to traditional methods; however, these devices have not been well studied in underserved adult patients (e.g., low-income, uninsured) who may face additional barriers to monitoring. Furthermore, there is limited data exploring long-term (3- to 6- month) health care team-based management of these devices in the primary care setting. This study will evaluate the perceived and experienced benefits and barriers of continuous glucose monitor (CGM) and traditional glucometer use and identify diabetes related outcomes associated with CGM use relative to usual care with self-monitoring of blood glucose (SMBG) in an underserved population.

Eligible adult (>=19 years of age) patients at participating clinics with type 2 diabetes, A1c >=9%, and concomitant insulin therapy and/or using two or more diabetes medications will be randomly enrolled to one of two groups: Freestyle Libre 2 CGM or traditional glucometer. Pre- and post-surveys will be used to evaluate perceived and experienced benefits and barriers to CGM use and diabetes-related outcomes will be compared between the groups using face-to-face, telephonic, and/or digital avenues. The latter aim will replicate current processes of team-based diabetes care which is blood glucose management from a pharmacist under collaborative practice with the primary care physician. Follow-up will also replicate these clinic processes throughout the 6-month period, including telephone calls and monthly in-clinic visits.

Type d'étude

Interventionnel

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Nebraska
      • Omaha, Nebraska, États-Unis, 68198-7400D
        • Nebraska Medicine

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

19 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Type 2 diabetes
  • A1c >9% at recruitment
  • On/initiating insulin or on two or more diabetes medications

Exclusion Criteria:

  • Current use of an insulin pump
  • On dialysis
  • Pregnant
  • Implanted medical device (e.g., pace-maker, defibrillator)
  • Intellectual or physical disabilities that may interfere with ability to properly use the Continuous Glucose Monitor (CGM)
  • Able to read English

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Non randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Continuous Glucose Monitoring

Participants will use a Freestyle Libre 2 monitoring device for 6 months to track blood glucose levels.

A Freestyle Libre 2 continuous glucose monitor (CGM) will be provided in the experimental arm of this study for 6 months.

Autres noms:
  • Moniteur flash-glucose
Comparateur actif: Traditional Glucometer Arm

Participants will use a traditional glucose monitoring device (glucometer) to self-monitor their blood glucose for 6 months to track blood glucose levels.

A traditional glucometer device will be assigned in the active comparitor arm of this study for 6 months.

Autres noms:
  • Gluomètre traditionnel

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Glycemic Control (Hemoglobin A1c)
Délai: Baseline, 3 months, and 6 months.

Glycemic control will be assessed by measuring hemoglobin A1c at baseline, 3 months, and 6 months. Values will be evaluated as a continuous variable and categorized as <7.0% vs >7.0% to <9.0% and >9.0%. Comparisons of the proportions of participants achieving a minimum of 1 point drop in hemoglobin A1c will be made between study arms.

Baseline, 3 months, and 6 months.

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Hypoglycemia
Délai: 6 months

Continuous glucose monitor (CGM) and glucometer blood glucose data will be evaluated to determine number and percentage of hypoglycemic readings (i.e., <70 mg/dL). For CGM data, % time within target range, % time below specific thresholds for hypoglycemia) will be captured and described.

6 months
Hyperglycemia
Délai: 6 months

Continuous glucose monitor (CGM) and glucometer blood glucose data will be evaluated to determine percentage of hyperglycemic values (i.e., >180 mg/dl) experienced. For CGM data, % time within target range, % time below specific thresholds for hypoglycemia) will be captured and described.

6 months
Blood Glucose Capture Rate
Délai: 6 months

Number of days without any blood glucose recordings will be captured as a percentage over the study period.

6 months
Perceived or Experienced Benefits and Barriers to Device Use
Délai: Baseline and 6 months

A pre- and post-survey will be provided to all participants to qualitatively identify benefits and barriers to access and use of their assigned device and willingness to continue CGM use (follow-up survey).

Baseline and 6 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Collaborateurs

Les enquêteurs

  • Chercheur principal: Drew C Prescott, PharmD, University of Nebraska

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

23 juillet 2023

Achèvement primaire (Réel)

20 juillet 2026

Achèvement de l'étude (Réel)

20 juillet 2026

Dates d'inscription aux études

Première soumission

27 février 2023

Première soumission répondant aux critères de contrôle qualité

8 mars 2023

Première publication (Réel)

13 mars 2023

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

12 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

9 novembre 2026

Dernière vérification

1 octobre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Oui

produit fabriqué et exporté des États-Unis.

Oui

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .