Heliox sur le travail respiratoire chez les patients adultes présentant une sténose des voies respiratoires inférieures
L'effet de l'héliox sur le travail respiratoire chez les patients adultes présentant une sténose des voies respiratoires inférieures
Heliox (a mixture of Helium and Oxygen) can reduce the work of breathing in patients with airway stenosis by modifying turbulent flow into laminar flow. The aim of this study was to analyze the effect of Heliox versus conventional oxygen therapy in patients with lower airway stenosis on muscular effort measured by electromyography and diaphragmatic ultrasound, thoracoabdominal synchrony assessed with plethysmographic bands, dyspnea, stridor, oxygen saturation, transcutaneous carbon dioxide value, blood pressure, heart rate and respiratory rate.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Lower airway stenosis results in increased work of breathing with stridor and dyspnea, as a consequence of the increased resistances caused by the reduction in airway diameter. Airway resistance also depends on the length of the airway and the type of gas flow. Heliox (a mixture of Helium and Oxygen) is a gas less dense than air, which can change the flow from turbulent to laminar, reducing airway resistance by 20 to 40%, and therefore decreasing the work of breathing. Heliox is an inert gas that does not react with biological membranes, so there are few complications associated with its use, the most relevant being hypoxemia when fixed mixtures are not used and the the fraction of inspired oxygen (FiO2) supplied is less than 21%. The aim of the study was to evaluate if during the perioperative period of lower airway stenosis the administration of Heliox compared to oxygen could reduce the work of breathing and improve dyspnea. For this purpose, patients were treated for 30 minutes with Heliox (fixed mixture of 70% helium and 30% oxygen) using a non rebreather mask or reservoir bag versus 30 minutes with oxygen 31% using a Venturi mask.
Type d'étude
Inscription (Réel)
Contacts et emplacements
Lieux d'étude
-
-
Madrid
-
Madrid, Madrid, Espagne, 28041
- Marta Corral Blanco
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
Méthode d'échantillonnage
Population étudiée
Patients will be recluted from the pneumology outpatient clinic of the Hospital 12 de Octubre
La description
Inclusion Criteria:
- Patients with lower airway stenosis evaluated at the Respiratory Endoscopy Unit of the Hospital Universitario 12 de Octubre on the waiting list for endoscopic intervention on stenosis.
- Stenosis grade ≥ 3 and Borg scale score > 2.
Exclusion Criteria:
- Presence of relevant comorbidities (uncontrolled ischemic heart disease, ventricular dysfunction, pneumopathies with severe respiratory insufficiency, severe pulmonary hypertension).
- Inability to perform the test due to severe dyspnea or need for emergency intervention.
- Patient on continuous mechanical ventilation, invasive or non-invasive.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Modèles d'observation: COHORT
- Perspectives temporelles: PROSPECTIVE
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
Airway Stenosis
Patients with lower airway stenosis on waiting list for endoscopic intervention on stenosis by respiratory endoscopy unit. |
Treatment for 30 minutes with Heliox from a commercial tank (Oxhelⓒ, Air Liquideⓒ) with a fixed mixture of 70% helium and 30% oxygen with non-rebreather mask or reservoir bag at a flow of 12-15 lpm.
Autres noms:
Treatment for 30 minutes with oxygen at FiO2 of 31% with Venturi mask.
Autres noms:
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Changes in Neural Ventilatory Drive (%):
Délai: 30 minutes with Heliox and 30 minutes with Oxygen 31%
|
Percentage over the Root Mean Square peak for parasternal electromyography (EMG): averaged of the square root of the peak value and the area under the curve of parasternal EMG (%RootMeanSquare) adjusted for respiratory frequency, as a surrogate of diaphragmatic EMG, and sternocleidomastoid EMG, which will give us information on accessory muscle activation. |
30 minutes with Heliox and 30 minutes with Oxygen 31%
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Diaphragmatic excursion assessed with ultrasound
Délai: At minute 15 during the Heliox test and at minute 15 during the Oxygen 31% test.
|
Assessment of muscular effort by measuring the diaphragmatic excursion (mm) at tidal volume and at vital capacity. |
At minute 15 during the Heliox test and at minute 15 during the Oxygen 31% test.
|
|
Thickening fraction of the diaphragm assessed by ultrasound
Délai: At minute 15 during the Heliox test and at minute 15 during the Oxygen 31% test.
|
Assessment of muscular effort by measuring the thickening fraction of the diaphragm in the apposition zone (%). |
At minute 15 during the Heliox test and at minute 15 during the Oxygen 31% test.
|
|
Changes in thoracoabdominal synchrony
Délai: Phase angle was calculated from 10 consecutive breaths at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Assessment of thoracoabdominal synchrony using thoracic and abdominal belts by calculating the phase angle with the Lissajoux loop method (plotting abdominal motion on the x-axis against thoracic motion on the y-axis). |
Phase angle was calculated from 10 consecutive breaths at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
|
Borg Scale Dyspnea evolution (points)
Délai: Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Degree of dyspnea will be determined by this validated scale with a result between 1 and 10 points.0: Not at all 0.5: Very, very light (hardly noticeable) 1: Very light, 2: Light, 3: Moderate , 4: Somewhat intense, 5: Intense, 6: Between 5 and 7, 7: Very intense, 8: Between 7 and 9, 9: Very, very intense (almost maximum ), 10: Maximum |
Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
|
Oxygen saturation
Délai: Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Measured by pulse-oximetry |
Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
|
Transcutaneous partial pressure of carbon dioxide
Délai: Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Transcutaneous monitor uses a noninvasive technique to measure the skin-surface partial pressure of carbon dioxide (PtcCO2) |
Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
|
Blood pressure
Délai: Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Non-invasive measurement with a sphygmomanometer |
Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
|
Heart rate
Délai: Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
number of beats per minute |
Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
|
Respiratory rate
Délai: Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Number of breaths per minute |
Basal value and at minutes 1, 5, 15 and 30 during the Heliox test and the Oxygen 31% test.
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Marta Corral Blanco, MD, Hospital 12 de Octubre
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- HELIOX ON AIRWAY STENOSIS
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .