Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Comparaison de la PPV et du VTI du LVOT pendant l'élévation passive des jambes pour prédire la réponse aux fluides

3 novembre 2026 mis à jour par: Ahmet Salih Tüzen, MD, Izmir Katip Celebi University

Comparaison de la variation de la pression pulsée et des variations du débit cardiaque basées sur le VTI du LVOT pendant la manœuvre de lever passif des jambes pour prédire la réponse liquidienne chez les patients de réanimation sous ventilation mécanique : une étude observationnelle prospective

Hemodynamic instability remains one of the leading causes of morbidity and mortality among critically ill patients in intensive care units. One major contributor to this instability is intravascular fluid deficit. Although fluid administration is often preferred as an initial intervention, inaccurate estimation of fluid requirements carries significant risks. Inadequate resuscitation may lead to tissue hypoperfusion and organ dysfunction, whereas excessive fluid loading is associated with pulmonary edema, increased intra-abdominal pressure, multi-organ dysfunction, and increased mortality. Consequently, reliable prediction of fluid responsiveness is considered a critical determinant in modern intensive care management.

The limited reliability of static parameters in predicting fluid responsiveness and the fact that PPV retains its validity only under specific clinical conditions highlight the need for more effective methods. In recent years, hemodynamic changes assessed during the passive leg raising (PLR) maneuver have gained prominence; particularly, left ventricular outflow tract velocity time integral (LVOT VTI)-based cardiac output measurements have been identified as a strong parameter for predicting fluid responsiveness . Moreover, changes in pulse pressure variation (PPV) during PLR have also been reported as a potential predictor; however, the number of studies prospectively comparing PPV variation and LVOT VTI-based cardiac output change within the same patient population remains limited . Therefore, the proposed study aims to fill this gap in the literature and contribute to fluid management in the intensive care setting.

The aim of this study is to compare the performance of PPV variation and LVOT VTI-based cardiac output change after the PLR maneuver in predicting fluid responsiveness among mechanically ventilated critically ill patients, and to determine the diagnostic value of both methods. The findings of the present study are expected to support more reliable decision-making in fluid therapy and provide clinical evidence toward the individualization of fluid management in intensive care practice.

Aperçu de l'étude

Description détaillée

This study is designed as a prospective observational trial. No additional intervention, procedure, or treatment beyond standard clinical practice will be performed. All data will be obtained during routine clinical management in our intensive care unit.

In mechanically ventilated patients with suspected fluid deficit, the passive leg raising (PLR) maneuver is applied as part of standard practice, during which changes in pulse pressure variation (PPV) are recorded by invasive arterial monitoring.

In this observational study, transthoracic echocardiographic (TTE) measurements of LVOT VTI will be performed by an experienced operator in addition to routine practice. Using pulse wave Doppler (PW), LVOT VTI will be recorded, and stroke volume (SV) and cardiac output (CO) will be calculated by multiplying the LVOT VTI value by the LVOT diameter. Consequently, changes in PPV and LVOT VTI-based CO during PLR will be compared.

Following TTE measurements of LVOT VTI and LVOT diameter in both the semi-recumbent position (45°) and immediately after PLR, SV and CO will be calculated. Based on these measurements, patients will be allocated into two groups:

  • Fluid responsive: Patients showing ≥10% increase in LVOT VTI-based CO following PLR
  • Non-fluid responsive: Patients showing <10% change in LVOT VTI-based CO following PLR

After grouping patients accordingly, PPV changes during PLR will be compared between the two groups. This will allow evaluation of the predictive performance of PPV variation relative to LVOT VTI-based CO change in determining fluid responsiveness. All measurements will be performed by an experienced clinician without disrupting standard patient care. No additional fluid loading, invasive procedures, or therapeutic interventions will be undertaken throughout the study.

The primary aim is to compare the diagnostic performance of PPV variation and LVOT VTI-based cardiac output changes following a PLR maneuver in predicting fluid responsiveness. The study seeks to determine the diagnostic value of both methods to support more individualised fluid management.

The recorded data will include:

  • Pre- and post-PLR LVOT VTI, stroke volume, cardiac output, and PPV values
  • Routine monitoring parameters (systolic/diastolic blood pressure, mean arterial pressure, heart rate, and SpO₂)
  • Demographic characteristics (age, sex, comorbidities) retrieved through the hospital database

Informed consent will be obtained from all participating patients or their legally authorized representatives.

Type d'étude

Observationnel

Inscription (Estimé)

48

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Ahmet Salih Tüzen, M.D.
  • Numéro de téléphone: +90 535 391 55 77
  • E-mail: astuzen@icloud.com

Sauvegarde des contacts de l'étude

Lieux d'étude

      • Izmir, Turquie (Türkiye)
        • Recrutement
        • Izmir Katip Celebi University Atatürk Training and Research Hospital İzmir, , Turkey
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

The study population consists of adult critically ill patients admitted to the Intensive Care Unit (ICU) who are receiving mechanical ventilation support. Eligible participants are those identified by the intensive care team as having a suspected intravascular fluid deficit, for whom a fluid responsiveness assessment is clinically indicated. The cohort specifically targets patients undergoing the Passive Leg Raising (PLR) maneuver as part of routine standard practice, where invasive arterial monitoring is available to record Pulse Pressure Variation (PPV).

La description

Inclusion Criteria:

  1. Adult patients aged ≥18 years
  2. Patients admitted to the intensive care unit receiving mechanical ventilation
  3. Presence of suspected intravascular fluid deficit (hypotension, negative fluid balance, or clinical signs of peripheral hypoperfusion)
  4. Patients in sinus rhythm
  5. Presence of invasive arterial blood pressure monitoring
  6. Adequate echocardiographic window allowing transthoracic echocardiographic measurement of LVOT VTI
  7. Patients ventilated with tidal volume ≥8 mL/kg (ideal body weight)
  8. Hemodynamically stable enough to allow measurement

Exclusion Criteria:

  1. Patients under 18 years of age
  2. Presence of atrial fibrillation or significant arrhythmias such as frequent ventricular or atrial ectopy
  3. Severe right ventricular dysfunction or significant tricuspid regurgitation
  4. Advanced aortic valve disease (severe stenosis or severe regurgitation)
  5. Patients with significant spontaneous breathing effort
  6. Patients receiving lung-protective low tidal volume ventilation strategy (<8 mL/kg) due to ARDS
  7. Inadequate echocardiographic window for LVOT VTI assessment
  8. Severe hemodynamic instability during measurement (sudden vasopressor escalation or need for resuscitation)
  9. Patients who refuse to participate or from whom written informed consent cannot be obtained from themselves or a first-degree relative

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: COHORT
  • Perspectives temporelles: PROSPECTIVE

Cohortes et interventions

Groupe / Cohorte
Fluid Responders

Defined as an increase in LVOT VTI-based Cardiac Output (CO) of ≥ 10% from baseline.

Fluid Non-Responders

Defined as an increase in LVOT VTI-based Cardiac Output (CO) of < 10% from baseline.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Change in Pulse Pressure Variation (Delta PPV)
Délai: Baseline (T0) and between 60 seconds after the PLR maneuver.

Pulse Pressure Variation (PPV) is recorded via invasive arterial monitoring at baseline (T0, semi-sitting) and during the Passive Leg Raising maneuver (T1).

Baseline (T0) and between 60 seconds after the PLR maneuver.

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Percentage Change in Cardiac Output (Delta CO)
Délai: Baseline (T0) and between 60 seconds after the PLR maneuver.

Cardiac Output (CO) is calculated using the Left Ventricular Outflow Tract Velocity Time Integral (LVOT VTI) and the LVOT diameter measured via transthoracic echocardiography.

Baseline (T0) and between 60 seconds after the PLR maneuver.
Correlation between Delta PPV and Delta CO
Délai: Baseline (T0) and between 60 seconds after the PLR maneuver.

Correlation Coefficient (r) between PPV Change and Cardiac Output Change

Baseline (T0) and between 60 seconds after the PLR maneuver.
Hemodynamic Parameter Changes (MAP, HR)
Délai: Baseline (T0) and between 60 seconds after the PLR maneuver.

Measurement of changes in mean arterial pressure and heart rate before and after PLR and comparison between groups.

Baseline (T0) and between 60 seconds after the PLR maneuver.
Diagnostic Accuracy (ROC-AUC, Sensitivity, Specificity, Cut-off)
Délai: Baseline (T0) and between 60 seconds after the PLR maneuver.

Evaluation of diagnostic performance of ΔPPV and ΔCO using receiver operating characteristic (ROC) analysis, including AUC, optimal cut-off value, sensitivity, and specificity for predicting fluid responsiveness.

Baseline (T0) and between 60 seconds after the PLR maneuver.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Murat Aksun, Izmir Katip Celebi University Atatürk Training and Research Hospital

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 janvier 2026

Achèvement primaire (Estimé)

1 janvier 2027

Achèvement de l'étude (Estimé)

1 juin 2027

Dates d'inscription aux études

Première soumission

13 décembre 2025

Première soumission répondant aux critères de contrôle qualité

13 décembre 2025

Première publication (Réel)

26 décembre 2025

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

4 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

3 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Description du régime IPD

All data necessary to support the study protocol, including de-identified individual participant data (IPD) related to study protocol, and primary and secondary outcome measures, will be made available upon reasonable request from qualified researchers for academic purposes, in accordance with institutional and ethical guidelines.

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner