Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Comparação do PPV e do VTI do LVOT Durante a Elevação Passiva dos Membros Inferiores para Prever a Resposta a Fluidos

3 de novembro de 2026 atualizado por: Ahmet Salih Tüzen, MD, Izmir Katip Celebi University

Comparação da Variação da Pressão de Pulso e das Alterações do Débito Cardíaco Baseadas no VTI do TIVE Durante a Manobra de Elevação Passiva dos Membros Inferiores na Previsão da Responsividade aos Fluidos em Doentes Críticos Ventilados Mecanicamente: Um Estudo Observacional Prospectivo

Hemodynamic instability remains one of the leading causes of morbidity and mortality among critically ill patients in intensive care units. One major contributor to this instability is intravascular fluid deficit. Although fluid administration is often preferred as an initial intervention, inaccurate estimation of fluid requirements carries significant risks. Inadequate resuscitation may lead to tissue hypoperfusion and organ dysfunction, whereas excessive fluid loading is associated with pulmonary edema, increased intra-abdominal pressure, multi-organ dysfunction, and increased mortality. Consequently, reliable prediction of fluid responsiveness is considered a critical determinant in modern intensive care management.

The limited reliability of static parameters in predicting fluid responsiveness and the fact that PPV retains its validity only under specific clinical conditions highlight the need for more effective methods. In recent years, hemodynamic changes assessed during the passive leg raising (PLR) maneuver have gained prominence; particularly, left ventricular outflow tract velocity time integral (LVOT VTI)-based cardiac output measurements have been identified as a strong parameter for predicting fluid responsiveness . Moreover, changes in pulse pressure variation (PPV) during PLR have also been reported as a potential predictor; however, the number of studies prospectively comparing PPV variation and LVOT VTI-based cardiac output change within the same patient population remains limited . Therefore, the proposed study aims to fill this gap in the literature and contribute to fluid management in the intensive care setting.

The aim of this study is to compare the performance of PPV variation and LVOT VTI-based cardiac output change after the PLR maneuver in predicting fluid responsiveness among mechanically ventilated critically ill patients, and to determine the diagnostic value of both methods. The findings of the present study are expected to support more reliable decision-making in fluid therapy and provide clinical evidence toward the individualization of fluid management in intensive care practice.

Visão geral do estudo

Descrição detalhada

This study is designed as a prospective observational trial. No additional intervention, procedure, or treatment beyond standard clinical practice will be performed. All data will be obtained during routine clinical management in our intensive care unit.

In mechanically ventilated patients with suspected fluid deficit, the passive leg raising (PLR) maneuver is applied as part of standard practice, during which changes in pulse pressure variation (PPV) are recorded by invasive arterial monitoring.

In this observational study, transthoracic echocardiographic (TTE) measurements of LVOT VTI will be performed by an experienced operator in addition to routine practice. Using pulse wave Doppler (PW), LVOT VTI will be recorded, and stroke volume (SV) and cardiac output (CO) will be calculated by multiplying the LVOT VTI value by the LVOT diameter. Consequently, changes in PPV and LVOT VTI-based CO during PLR will be compared.

Following TTE measurements of LVOT VTI and LVOT diameter in both the semi-recumbent position (45°) and immediately after PLR, SV and CO will be calculated. Based on these measurements, patients will be allocated into two groups:

  • Fluid responsive: Patients showing ≥10% increase in LVOT VTI-based CO following PLR
  • Non-fluid responsive: Patients showing <10% change in LVOT VTI-based CO following PLR

After grouping patients accordingly, PPV changes during PLR will be compared between the two groups. This will allow evaluation of the predictive performance of PPV variation relative to LVOT VTI-based CO change in determining fluid responsiveness. All measurements will be performed by an experienced clinician without disrupting standard patient care. No additional fluid loading, invasive procedures, or therapeutic interventions will be undertaken throughout the study.

The primary aim is to compare the diagnostic performance of PPV variation and LVOT VTI-based cardiac output changes following a PLR maneuver in predicting fluid responsiveness. The study seeks to determine the diagnostic value of both methods to support more individualised fluid management.

The recorded data will include:

  • Pre- and post-PLR LVOT VTI, stroke volume, cardiac output, and PPV values
  • Routine monitoring parameters (systolic/diastolic blood pressure, mean arterial pressure, heart rate, and SpO₂)
  • Demographic characteristics (age, sex, comorbidities) retrieved through the hospital database

Informed consent will be obtained from all participating patients or their legally authorized representatives.

Tipo de estudo

Observacional

Inscrição (Estimado)

48

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

  • Nome: Ahmet Salih Tüzen, M.D.
  • Número de telefone: +90 535 391 55 77
  • E-mail: astuzen@icloud.com

Estude backup de contato

Locais de estudo

      • Izmir, Turquia (Türkiye)
        • Recrutamento
        • Izmir Katip Celebi University Atatürk Training and Research Hospital İzmir, , Turkey
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

The study population consists of adult critically ill patients admitted to the Intensive Care Unit (ICU) who are receiving mechanical ventilation support. Eligible participants are those identified by the intensive care team as having a suspected intravascular fluid deficit, for whom a fluid responsiveness assessment is clinically indicated. The cohort specifically targets patients undergoing the Passive Leg Raising (PLR) maneuver as part of routine standard practice, where invasive arterial monitoring is available to record Pulse Pressure Variation (PPV).

Descrição

Inclusion Criteria:

  1. Adult patients aged ≥18 years
  2. Patients admitted to the intensive care unit receiving mechanical ventilation
  3. Presence of suspected intravascular fluid deficit (hypotension, negative fluid balance, or clinical signs of peripheral hypoperfusion)
  4. Patients in sinus rhythm
  5. Presence of invasive arterial blood pressure monitoring
  6. Adequate echocardiographic window allowing transthoracic echocardiographic measurement of LVOT VTI
  7. Patients ventilated with tidal volume ≥8 mL/kg (ideal body weight)
  8. Hemodynamically stable enough to allow measurement

Exclusion Criteria:

  1. Patients under 18 years of age
  2. Presence of atrial fibrillation or significant arrhythmias such as frequent ventricular or atrial ectopy
  3. Severe right ventricular dysfunction or significant tricuspid regurgitation
  4. Advanced aortic valve disease (severe stenosis or severe regurgitation)
  5. Patients with significant spontaneous breathing effort
  6. Patients receiving lung-protective low tidal volume ventilation strategy (<8 mL/kg) due to ARDS
  7. Inadequate echocardiographic window for LVOT VTI assessment
  8. Severe hemodynamic instability during measurement (sudden vasopressor escalation or need for resuscitation)
  9. Patients who refuse to participate or from whom written informed consent cannot be obtained from themselves or a first-degree relative

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Modelos de observação: COHORT
  • Perspectivas de Tempo: PROSPECTIVE

Coortes e Intervenções

Grupo / Coorte
Fluid Responders

Defined as an increase in LVOT VTI-based Cardiac Output (CO) of ≥ 10% from baseline.

Fluid Non-Responders

Defined as an increase in LVOT VTI-based Cardiac Output (CO) of < 10% from baseline.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Change in Pulse Pressure Variation (Delta PPV)
Prazo: Baseline (T0) and between 60 seconds after the PLR maneuver.

Pulse Pressure Variation (PPV) is recorded via invasive arterial monitoring at baseline (T0, semi-sitting) and during the Passive Leg Raising maneuver (T1).

Baseline (T0) and between 60 seconds after the PLR maneuver.

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Percentage Change in Cardiac Output (Delta CO)
Prazo: Baseline (T0) and between 60 seconds after the PLR maneuver.

Cardiac Output (CO) is calculated using the Left Ventricular Outflow Tract Velocity Time Integral (LVOT VTI) and the LVOT diameter measured via transthoracic echocardiography.

Baseline (T0) and between 60 seconds after the PLR maneuver.
Correlation between Delta PPV and Delta CO
Prazo: Baseline (T0) and between 60 seconds after the PLR maneuver.

Correlation Coefficient (r) between PPV Change and Cardiac Output Change

Baseline (T0) and between 60 seconds after the PLR maneuver.
Hemodynamic Parameter Changes (MAP, HR)
Prazo: Baseline (T0) and between 60 seconds after the PLR maneuver.

Measurement of changes in mean arterial pressure and heart rate before and after PLR and comparison between groups.

Baseline (T0) and between 60 seconds after the PLR maneuver.
Diagnostic Accuracy (ROC-AUC, Sensitivity, Specificity, Cut-off)
Prazo: Baseline (T0) and between 60 seconds after the PLR maneuver.

Evaluation of diagnostic performance of ΔPPV and ΔCO using receiver operating characteristic (ROC) analysis, including AUC, optimal cut-off value, sensitivity, and specificity for predicting fluid responsiveness.

Baseline (T0) and between 60 seconds after the PLR maneuver.

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Murat Aksun, Izmir Katip Celebi University Atatürk Training and Research Hospital

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de janeiro de 2026

Conclusão Primária (Estimado)

1 de janeiro de 2027

Conclusão do estudo (Estimado)

1 de junho de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

13 de dezembro de 2025

Enviado pela primeira vez que atendeu aos critérios de CQ

13 de dezembro de 2025

Primeira postagem (Real)

26 de dezembro de 2025

Atualizações de registro de estudo

Última Atualização Postada (Real)

4 de novembro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

3 de novembro de 2026

Última verificação

1 de novembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Descrição do plano IPD

All data necessary to support the study protocol, including de-identified individual participant data (IPD) related to study protocol, and primary and secondary outcome measures, will be made available upon reasonable request from qualified researchers for academic purposes, in accordance with institutional and ethical guidelines.

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever