CET-REM (correlazione della risposta ECT ai marcatori EEG)
Correlazione della risposta alla terapia elettroconvulsiva ai complessi ictali elettroencefalografici e ai marcatori postictali
Single-center study to determine the relationship between changes in depression symptoms and electroencephalographic (EEG) patterns induced by electroconvulsive therapy (ECT)
Panoramica dello studio
Stato
Stato
Condizioni
Condizioni
Intervento / Trattamento
Intervento / Trattamento
Descrizione dettagliata
Electroconvulsive therapy (ECT) is an effective treatment for many psychiatric illnesses, including major depressive disorder. While effective, objective markers have not been developed to predict clinical outcome trajectories following ECT. This is important given the risks and costs incurred during a full treatment course. Electroencephalography (EEG) is typically employed to monitor the generation and termination of ECT-induced seizures but leverage of markers toward prognostication remains a future goal. The investigators have characterized two distinct EEG patterns associated with ECT-induced generalized seizures and have two sleep markers that may serve as markers for predicting response to treatment. Central Positive Complexes (CPCs) are large ictal complexes with a scalp topology of voltage declining from the top of the head. CPCs are localized to cortical areas that are involved in the formation of sleep spindles and slow wave sleep. A pattern of low-voltage activity, known as post-ictal generalized electroencephalographic suppression (PGES), is frequently used to document termination of these seizures. Additionally, two EEG markers of sleep microstructure may have utility given their association with synaptic plasticity, a process presumably invoked over the course of ECT-induced recovery from psychiatric illness as pathologic neural circuitry undergoes reconfiguration. These two markers, sleep spindles and slow waves show altered expression patterns in patients with psychiatric disorders, and thus may be useful as objective markers of ECT responsiveness. None of the above EEG markers have been explored for an association to interval changes in disease severity over the course of ECT. This project will incisively probe the relationships between temporal trajectories of major depressive disorder severity and longitudinal measurements of ictal and postictal EEG markers.
Tipo di studio
Tipo di studio
Iscrizione (Effettivo)
Iscrizione
Fase
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
Missouri
-
St Louis, Missouri, Stati Uniti, 63110
- Washington University School of Medicine/Barnes-Jewish Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age 18 years or greater
- Referral for ECT index course for treatment-resistant depression (unipolar major depressive disorder or bipolar depression), major depressive disorder with psychotic symptoms, schizophrenia or schizoaffective being treated for a depressed episode, unspecified depression
Exclusion Criteria:
- Schizophrenia or schizoaffective disorder not being treated for a depressed episode.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Numero di armi
Armi e interventi
Gruppo di partecipanti / ArmGruppo di partecipanti / Arm |
Intervento / TrattamentoIntervento / Trattamento |
|---|---|
|
Sperimentale: Pazienti con depressione resistente al trattamento
|
EEG on nights after ECT session will be recorded using the DREEM device. Sleep EEG data will also be acquired for a minimum of one night prior to the first ECT session, providing a true baseline measure. The DREEM device allows continuous recording of multichannel EEG The Quick Inventory of Depressive Symptomatology-Self Report (QIDS-SR16) is a measure of depression symptom severity that has been validated for clinical and research use53. It is a standard self-report measurement completed by patients prior to each ECT session A high-density 65-electrode EEG scalp electrode net (EGI/Philips) with Elefix conductive gel injected within Ag/AgCl electrode sensors is utilized to monitor brain activity during the ictal period A board-certified epileptologist will review all seizures to assess seizure parameters, including duration of seizure and interval of PGES. Preprocessing of the PGES periods will be accomplished with band-pass filtering from 2 to 30 Hz with 1st order Butterworth filters. |
Cosa sta misurando lo studio?
Misure di risultato primarie
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Interval change in Quick Inventory of Depressive Symptomatology-16 Item Self Report (QIDS-SR16) between ECT sessions.
Lasso di tempo: Up to 8 weeks during patients ECT treatment course
|
16 item Self-report questionnaire that best describes the participant's depressive symptoms over the last seven days. Scale: 0=never or do not, 3=nearly all the time, or the highest level of time listed on the question. |
Up to 8 weeks during patients ECT treatment course
|
|
Duration of Central Positive Complexes during ECT treatments.
Lasso di tempo: Up to 8 weeks during patients ECT treatment course
|
Total time (in seconds) during the ictal period for which CPCs are present in the EEG immediately following seizure induction until termination of the seizure. Range of values: 0 - 300 seconds |
Up to 8 weeks during patients ECT treatment course
|
|
Duration of PGES during ECT treatments.
Lasso di tempo: Up to 8 weeks during patients ECT treatment course
|
Total time (in seconds) during the postictal period for which PGES is present in the EEG immediately following seizure termination for up to 5 minutes. Range of values: 0 - 300 seconds |
Up to 8 weeks during patients ECT treatment course
|
|
Density of EEG sleep spindles during non-rapid eye movement (NREM) stages N2 on evenings following ECT treatments.
Lasso di tempo: Up to 8 weeks during patients ECT treatment course
|
The total number of EEG sleep spindles per minute present during N2 sleep. Range of values: 0 - 60 spindles/min |
Up to 8 weeks during patients ECT treatment course
|
|
Slow wave activity (SWA) during N3 sleep on evenings following ECT treatments
Lasso di tempo: Up to 8 weeks during patients ECT treatment course
|
Total power of EEG slow waves per minute present during the first identified cycle of N3 sleep Range of values: 0 - 50 dB/min |
Up to 8 weeks during patients ECT treatment course
|
Collaboratori e investigatori
Sponsor
Sponsor
Investigatori
Investigatori
- Investigatore principale: MohammadMehdi Kafashan, Washington University School of Medicine
Pubblicazioni e link utili
Pubblicazioni generali
- Lopez J, Hoffmann R, Armitage R. Reduced sleep spindle activity in early-onset and elevated risk for depression. J Am Acad Child Adolesc Psychiatry. 2010 Sep;49(9):934-43. doi: 10.1016/j.jaac.2010.05.014. Epub 2010 Jul 24.
- Kho KH, van Vreeswijk MF, Simpson S, Zwinderman AH. A meta-analysis of electroconvulsive therapy efficacy in depression. J ECT. 2003 Sep;19(3):139-47. doi: 10.1097/00124509-200309000-00005.
- Kafashan M, Brian Hickman L, Labonte AK, Huels ER, Maybrier H, Guay CS, Subramanian S, Farber NB, Ching S, Hogan RE, Kelz MB, Avidan MS, Mashour GA, Palanca BJA. Quiescence during burst suppression and postictal generalized EEG suppression are distinct patterns of activity. Clin Neurophysiol. 2022 Oct;142:125-132. doi: 10.1016/j.clinph.2022.07.493. Epub 2022 Jul 30.
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Inizio studio
Completamento primario (Stimato)
Completamento primario
Completamento dello studio (Stimato)
Completamento dello studio
Date di iscrizione allo studio
Primo inviato
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Primo Inserito
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento pubblicato
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
Altri numeri di identificazione dello studio
- 202006108
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .