MRIの画像技術
Background:
- Magnetic resonance imaging (MRI) scans must be performed according to specified sets of parameters that provide optimal images of each organ and each area of the body. These scanning parameters are often specific to the institution or organization at which they are employed, and may also depend on the manufacturer of the MRI scanning equipment. Because MRI scanning equipment is always being updated and upgraded, researchers are interested in developing new and optimized scanning parameters for MRI scans.
Objectives:
- To improve current methods and develop new techniques for magnetic resonance imaging.
Eligibility:
- Individuals 18 years of age and older who are either volunteers or current NIH protocol participants.
- Participants must not have any medical history factors (e.g., extreme claustrophobia, history of metal implants) that would prevent them from receiving MRI scans.
Design:
- Participants will have at least one MRI scan that will last from 20 minutes to 2 hours (most scans will last between 45 and 90 minutes). The total time commitment for most visits will be approximately 4 hours from start to finish.
- Some MRI techniques require standard monitoring equipment or specific procedures during the scanning, such as an electrocardiogram.
- Participants will have blood samples taken at the time of the scan. Some MRI studies will require the use of a contrast agent that will be administered during the scan.
- Volunteers may be asked to return for additional MRI scans over the course of a few years. Follow-up scans may be done on the same part of the body or on different parts of the body. No more than one MRI scan will be performed in any 4-week period for this protocol.
調査の概要
詳細な説明
Magnetic Resonance (MR) Imaging performed on volunteers will be used to develop and optimize techniques useful in the advancement of MRI technology.
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Tracy L Cropper, R.N.
- 電話番号:(301) 402-6132
- メール:tcropper@cc.nih.gov
研究連絡先のバックアップ
- 名前:Bernadette A Redd, M.D.
- 電話番号:(301) 215-0785
- メール:bernadette.redd@nih.gov
研究場所
-
-
Maryland
-
Bethesda、Maryland、アメリカ、20892
- 募集
- National Institutes of Health Clinical Center
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
Volunteers (maybe Volunteers, NIH employee and current NIH protocol participants)
説明
- INCLUSION CRITERIA:
A. Volunteer individuals
B. Lab Eligibility parameters (for contrast scans within 4 weeks of gadolinium injection):
C. Creatinine below upper normal limit
D. eGFR >= 60 mL/min/1.73m2
E. Age >= 60 or history of renal disease: test GFR within 1 week prior to contrast
F. Willing to travel to the NIH for follow-up visits.
G. 18 years old
H. Able to understand and sign informed consent
I. No MRI scan with gadolinium injection in the last 6 months under this protocol.
EXCLUSION CRITERIA:
A. Implanted metal clips or wires of the type which may concentrate radiofrequency fields or cause tissue damages from twisting in a Magnetic field. Examples:
- Aneurysm clip, implanted neural stimulator,
- Implanted cardiac pacemaker, defibrillator, or certain other implanted electrical or metallic devices,
- Cochlear implant, ocular foreign body (metal shavings),
- Any implanted device (pumps, infusion devices, etc.),
- Shrapnel injuries,
- History of metal in head or eyes or other parts of the body.
B. Pregnant women
C. Paralyzed hemidiaphragm
D. Over 500 lbs and/or a body circumference that prevents the study subject from laying flat in the scanner
E. Surgery of uncertain type
F. Untreatable claustrophobia otherwise requiring anesthesia.
G. Any contraindications that the Physician identifies from the subject, MRI Safety Questionnaire, and/or History and Physical.
EXCLUSION FOR PARTICIPANTS FOR GADOLINIUM CONTRAST:
(Inclusive of the above exclusion criteria):
A. Allergy to gadolinium for scans using contrast; will be eligible for non-contrast scans.
B. Acute renal failure, renal transplant, dialysis and renal failure individuals (eGFR <60 mL/min/1.73m2 and/or clinically diagnosed).
C. Individuals with a history of liver transplant or severe liver disease.
D. Lactating women
E. Individuals with hemoglobinopathies or severe asthma.
F. Patient preference to not undergo intravenous line placement and/or receive gadolinium contrast. Contrast administration is optional and participants may still undergo a non-contrast study.
G. GBCA with an MRI scan in the last 6 months. This includes scan performed with GBCA at any outside institution and / or at the clinical center .In addition, they cannot have reached their maximum of 4 GBCA imaging studies under this protocol. They will be excluded from having a contrast enhanced MRI, but will not be excluded from the protocol for non-contrast MRI studies.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 観測モデル:OTHER
- 時間の展望:PROSPECTIVE
コホートと介入
グループ/コホート |
|---|
|
Volunteers
Volunteers (maybe Volunteers, NIH employee and current NIH protocol participants) |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
To refine current methodology and develop new techniques for MRI
時間枠:End of study
|
To refine current methodology and develop new techniques for magnetic resonance imaging in the general population. |
End of study
|
協力者と研究者
捜査官
- 主任研究者:Bernadette A Redd, M.D.、National Institutes of Health Clinical Center (CC)
出版物と役立つリンク
一般刊行物
- Mattay VS, Weinberger DR, Barrios FA, Sobering GS, Kotrla KJ, van Gelderen P, Duyn JH, Sexton RH, Moonen CT, Frank JA. Brain mapping with functional MR imaging: comparison of gradient-echo--based exogenous and endogenous contrast techniques. Radiology. 1995 Mar;194(3):687-91. doi: 10.1148/radiology.194.3.7862963.
- Perez-Rodriguez J, Lai S, Ehst BD, Fine DM, Bluemke DA. Nephrogenic systemic fibrosis: incidence, associations, and effect of risk factor assessment--report of 33 cases. Radiology. 2009 Feb;250(2):371-7. doi: 10.1148/radiol.2502080498.
- Frank JA, Mattay VS, Duyn J, Sobering G, Barrios FA, Zigun J, Sexton R, Kwok P, Woo J, Moonen C, et al. Measurement of relative cerebral blood volume changes with visual stimulation by 'double-dose' gadopentetate-dimeglumine-enhanced dynamic magnetic resonance imaging. Invest Radiol. 1994 Jun;29 Suppl 2:S157-60. doi: 10.1097/00004424-199406001-00052. No abstract available.
- Ahlman MA, Raman FS, Penzak SR, Pang J, Fan Z, Liu S, Gai N, Li D, Bluemke DA. Part 1 - Coronary angiography with gadofosveset trisodium: a prospective feasibility study evaluating injection techniques for steady-state imaging. BMC Cardiovasc Disord. 2015 Dec 22;15:177. doi: 10.1186/s12872-015-0176-0.
- Raman FS, Nacif MS, Cater G, Gai N, Jones J, Li D, Sibley CT, Liu S, Bluemke DA. 3.0-T whole-heart coronary magnetic resonance angiography: comparison of gadobenate dimeglumine and gadofosveset trisodium. Int J Cardiovasc Imaging. 2013 Jun;29(5):1085-94. doi: 10.1007/s10554-013-0192-z. Epub 2013 Mar 21.
研究記録日
主要日程の研究
研究開始 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (推定)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。