ハイブリッドロボット+FES 脳卒中リハビリテーション
アセスメントとそれに続く在宅ハイブリッド ロボット + FES リハビリテーション 脳卒中後
The investigators have developed a novel robot-guided stretching under intelligent control and combine it with active movement training, which helped increase joint ROM, reduce spasticity and joint stiffness, increase muscle force output, and improve locomotion. However, for stroke survivors with sensorimotor impairment, their peripheral muscle may not sufficiently be recruited. Functional electrical stimulation (FES), has been shown its advantage to activate the peripheral muscles for people with neurological conditions. The investigators thus make a hybrid robot-FES rehabilitation system, combining the advantage of robot and FES technologies for stroke motor recovery. The investigators further would like to translate the technologies from lab to home-based training. Thus, the investigators will conduct a randomized, controlled, primarily home-based clinical trial using an ankle robot alone or combined with functional electrical stimulation (FES) to treat sensorimotor and locomotion impairments post-stroke.
調査の概要
状態
条件
研究の種類
入学 (推定)
段階
- フェーズ2
- フェーズ 1
連絡先と場所
研究連絡先
- 名前:Li-qun Zhang, PhD
- 電話番号:410 706 2145
- メール:L-Zhang@som.umaryland.edu
研究場所
-
-
Maryland
-
Baltimore、Maryland、アメリカ、21201
- 募集
- University of Maryland School of Medicine
-
コンタクト:
- Li-Qun Zhang, PhD
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age 18-85;
- Able to ambulate at least 10 meters without human assistance, with or without an assistive device
- ≥ 6 months post stroke;
- having a caregiver to assist in training at home.
Exclusion Criteria:
- having expressive and receptive aphasia;
- an inability to follow multi-step commands;
- enrolled in another lower limb rehabilitation program;
- having severe pain in the paralyzed lower-limb;
- >30º ankle plantar flexion contracture;
- Having implanted electronic device such as a pacemaker, spinal cord, or deep brain stimulator because FES may potentially interfere with their functions.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:FES+robot
Participants in this group will have FES during ankle robot training |
Patients will use the ankle robot device as the ankle training group. Also, water-based FES electrodes positioned inside a soft garment will be secured over the DF and PF muscles by wrapping the garment around the leg just below the knee joint. Stimulation intensity will be increased to maximal tolerance of each participant. Electrically induced contraction timing will be triggered by the ankle robot in synchrony with the ankle dorsi and plantar flexion movements. |
|
アクティブコンパレータ:Robot
Participants in this group will have ankle robot training only |
Patients will be seated with the paretic foot strapped to the footplate the knee at full extension. The operator will set up and measure (using the robot) ankle passive DF and PF ROM limits. The robot training will include passive stretching, robot interactive game-based training, and cool-down stretching. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Fugl-Meyer Lower Extremity
時間枠:Baseline
|
The assessment is a measure of lower extremity (LE) motor and sensory impairments post-stroke. |
Baseline
|
|
Fugl-Meyer Lower Extremity
時間枠:6 weeks
|
The assessment is a measure of lower extremity (LE) motor and sensory impairments post-stroke. |
6 weeks
|
|
Fugl-Meyer Lower Extremity
時間枠:12 weeks
|
The assessment is a measure of lower extremity (LE) motor and sensory impairments post-stroke. |
12 weeks
|
|
Dorsiflexion active range of motion
時間枠:Baseline
|
Joint ankle active range of motion measured by ankle robot. |
Baseline
|
|
Dorsiflexion active range of motion
時間枠:6 weeks
|
Joint ankle active range of motion measured by ankle robot. |
6 weeks
|
|
Dorsiflexion active range of motion
時間枠:12 weeks
|
Joint ankle active range of motion measured by ankle robot. |
12 weeks
|
|
6 minutes walking test
時間枠:Baseline
|
The six-minute walk test (6MWT) measures the distance an individual is able to walk over a total of six minutes on a hard, flat surface. The goal is for the individual to walk as far as possible in six minutes. |
Baseline
|
|
6 minutes walking test
時間枠:6 weeks
|
The six-minute walk test (6MWT) measures the distance an individual is able to walk over a total of six minutes on a hard, flat surface. The goal is for the individual to walk as far as possible in six minutes. |
6 weeks
|
|
6 minutes walking test
時間枠:12 weeks
|
The six-minute walk test (6MWT) measures the distance an individual is able to walk over a total of six minutes on a hard, flat surface. The goal is for the individual to walk as far as possible in six minutes. |
12 weeks
|
|
Medical thickness of medial gastrocnemius muscle and tibial anterior muscle
時間枠:Baseline
|
B-model ultrasound will be used to scan the muscle thickness, and the image will be further proceeded to measure the muscle thickness with unit in centimetres. |
Baseline
|
|
Medical thickness of medial gastrocnemius muscle and tibial anterior muscle
時間枠:6 week
|
B-model ultrasound will be used to scan the muscle thickness, and the image will be further proceeded to measure the muscle thickness with unit in centimetres. |
6 week
|
|
Medical thickness of medial gastrocnemius muscle and tibial anterior muscle
時間枠:12 week
|
B-model ultrasound will be used to scan the muscle thickness, and the image will be further proceeded to measure the muscle thickness with unit in centimetres. |
12 week
|
|
Muscle fiber pennation angle of medial gastrocnemius muscle and tibial anterior muscle
時間枠:Baseline
|
B-model ultrasound will be used to scan the muscle and the image will be further proceeded to measure the muscle fiber pennation angle with unit in degree. |
Baseline
|
|
Muscle fiber pennation angle of medial gastrocnemius muscle and tibial anterior muscle
時間枠:6 week
|
B-model ultrasound will be used to scan the muscle and the image will be further proceeded to measure the muscle fiber pennation angle with unit in degree. |
6 week
|
|
Muscle fiber pennation angle of medial gastrocnemius muscle and tibial anterior muscle
時間枠:12 week
|
B-model ultrasound will be used to assess the muscle thickness, muscle fiber pennation angle. Elasticity will be measured using ultrasound elastography. |
12 week
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Timed up-to-go
時間枠:Baseline
|
The Timed Up and Go test (TUG) is a simple test used to assess a person's mobility and requires both static and dynamic balance. It uses the time that a person takes to rise from a chair, walk three meters, turn around, walk back to the chair, and sit down. |
Baseline
|
|
Timed up-to-go
時間枠:6 weeks
|
The Timed Up and Go test (TUG) is a simple test used to assess a person's mobility and requires both static and dynamic balance. It uses the time that a person takes to rise from a chair, walk three meters, turn around, walk back to the chair, and sit down. |
6 weeks
|
|
Timed up-to-go
時間枠:12 weeks
|
The Timed Up and Go test (TUG) is a simple test used to assess a person's mobility and requires both static and dynamic balance. It uses the time that a person takes to rise from a chair, walk three meters, turn around, walk back to the chair, and sit down. |
12 weeks
|
|
Stroke Rehabilitation Assessment of Movement (STREAM)
時間枠:baseline
|
Stroke Rehabilitation Assessment of Movement Measure (STREAM) provides therapists with a quantitative measurement of motor functioning and basic mobility deficits among patients who had a stroke through the performance of 30 voluntary motor tasks of the upper extremities (UE) and lower extremities (LE). |
baseline
|
|
Stroke Rehabilitation Assessment of Movement (STREAM)
時間枠:6 weeks
|
Stroke Rehabilitation Assessment of Movement Measure (STREAM) provides therapists with a quantitative measurement of motor functioning and basic mobility deficits among patients who had a stroke through the performance of 30 voluntary motor tasks of the upper extremities (UE) and lower extremities (LE). |
6 weeks
|
|
Stroke Rehabilitation Assessment of Movement (STREAM)
時間枠:12 weeks
|
Stroke Rehabilitation Assessment of Movement Measure (STREAM) provides therapists with a quantitative measurement of motor functioning and basic mobility deficits among patients who had a stroke through the performance of 30 voluntary motor tasks of the upper extremities (UE) and lower extremities (LE). |
12 weeks
|
|
Brief Balance Evaluation Systems Test(Brief-BESTest)
時間枠:baseline
|
The Brief BESTest is a clinical balance assessment tool. It is an abbreviated version of Balance Evaluation Systems Test (BESTest), designed to assess 6 different aspects contributing to postural control in standing and walking. |
baseline
|
|
Brief Balance Evaluation Systems Test(Brief-BESTest)
時間枠:6 weeks
|
The Brief BESTest is a clinical balance assessment tool. It is an abbreviated version of Balance Evaluation Systems Test (BESTest), designed to assess 6 different aspects contributing to postural control in standing and walking. |
6 weeks
|
|
Brief Balance Evaluation Systems Test(Brief-BESTest)
時間枠:12 weeks
|
The Brief BESTest is a clinical balance assessment tool. It is an abbreviated version of Balance Evaluation Systems Test (BESTest), designed to assess 6 different aspects contributing to postural control in standing and walking. |
12 weeks
|
|
Modified Ashworth Scale (MAS)
時間枠:baseline
|
The Modified Ashworth Scale is the most widely used assessment tool to measure resistance to limb movement in a clinic setting. Scores range from 0-4, with 6 choices. 0 (0) - No increase in muscle tone; 1 (1) - Slight increase in muscle tone, manifested by a catch and release or by minimal resistance at the end of the range of motion when the affected part(s) is moved in flexion or extension; 1+ (2) - Slight increase in muscle tone, manifested by a catch, followed by minimal resistance throughout the remainder (less than half) of the range of movement (ROM); 2 (3) - More marked increase in muscle tone through most of the ROM, but affect part(s) easily moved; 3 (4) - Considerable increase in muscle tone passive, movement difficult; 4 (5) - Affected part(s) rigid in flexion or extension. |
baseline
|
|
Modified Ashworth Scale (MAS)
時間枠:6 weeks
|
The Modified Ashworth Scale is the most widely used assessment tool to measure resistance to limb movement in a clinic setting. Scores range from 0-4, with 6 choices. 0 (0) - No increase in muscle tone; 1 (1) - Slight increase in muscle tone, manifested by a catch and release or by minimal resistance at the end of the range of motion when the affected part(s) is moved in flexion or extension; 1+ (2) - Slight increase in muscle tone, manifested by a catch, followed by minimal resistance throughout the remainder (less than half) of the range of movement (ROM); 2 (3) - More marked increase in muscle tone through most of the ROM, but affect part(s) easily moved; 3 (4) - Considerable increase in muscle tone passive, movement difficult; 4 (5) - Affected part(s) rigid in flexion or extension. |
6 weeks
|
|
Modified Ashworth Scale (MAS)
時間枠:12 weeks
|
The Modified Ashworth Scale is the most widely used assessment tool to measure resistance to limb movement in a clinic setting. Scores range from 0-4, with 6 choices. 0 (0) - No increase in muscle tone; 1 (1) - Slight increase in muscle tone, manifested by a catch and release or by minimal resistance at the end of the range of motion when the affected part(s) is moved in flexion or extension; 1+ (2) - Slight increase in muscle tone, manifested by a catch, followed by minimal resistance throughout the remainder (less than half) of the range of movement (ROM); 2 (3) - More marked increase in muscle tone through most of the ROM, but affect part(s) easily moved; 3 (4) - Considerable increase in muscle tone passive, movement difficult; 4 (5) - Affected part(s) rigid in flexion or extension. |
12 weeks
|
|
10-meter walk test (10MWT)
時間枠:baseline
|
The 10 Metre Walk Test is a performance measure used to assess walking speed in metres per second over a short distance. It can be employed to determine functional mobility, gait, and vestibular function. |
baseline
|
|
10-meter walk test (10MWT)
時間枠:6 weeks
|
The 10 Metre Walk Test is a performance measure used to assess walking speed in metres per second over a short distance. It can be employed to determine functional mobility, gait, and vestibular function. |
6 weeks
|
|
10-meter walk test (10MWT)
時間枠:12 weeks
|
The 10 Metre Walk Test is a performance measure used to assess walking speed in metres per second over a short distance. It can be employed to determine functional mobility, gait, and vestibular function. |
12 weeks
|
|
Stiffness of medial gastrocnemius muscle and tibial anterior muscle.
時間枠:Baseline
|
Supersonic shear wave elastography will be used to estimate the shear wave speed(m/s) of the muscles. |
Baseline
|
|
Stiffness of medial gastrocnemius muscle and tibial anterior muscle.
時間枠:6 weeks
|
Supersonic shear wave elastography will be used to estimate the shear wave speed(m/s) of the muscles. |
6 weeks
|
|
Stiffness of medial gastrocnemius muscle and tibial anterior muscle.
時間枠:12 weeks
|
Supersonic shear wave elastography will be used to estimate the shear wave speed(m/s) of the muscles. |
12 weeks
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- Selles RW, Li X, Lin F, Chung SG, Roth EJ, Zhang LQ. Feedback-controlled and programmed stretching of the ankle plantarflexors and dorsiflexors in stroke: effects of a 4-week intervention program. Arch Phys Med Rehabil. 2005 Dec;86(12):2330-6. doi: 10.1016/j.apmr.2005.07.305.
- Zhang LQ, Chung SG, Bai Z, Xu D, van Rey EM, Rogers MW, Johnson ME, Roth EJ. Intelligent stretching of ankle joints with contracture/spasticity. IEEE Trans Neural Syst Rehabil Eng. 2002 Sep;10(3):149-57. doi: 10.1109/TNSRE.2002.802857.
- Ren Y, Wu YN, Yang CY, Xu T, Harvey RL, Zhang LQ. Developing a Wearable Ankle Rehabilitation Robotic Device for in-Bed Acute Stroke Rehabilitation. IEEE Trans Neural Syst Rehabil Eng. 2017 Jun;25(6):589-596. doi: 10.1109/TNSRE.2016.2584003. Epub 2016 Jun 22.
- Embrey DG, Holtz SL, Alon G, Brandsma BA, McCoy SW. Functional electrical stimulation to dorsiflexors and plantar flexors during gait to improve walking in adults with chronic hemiplegia. Arch Phys Med Rehabil. 2010 May;91(5):687-96. doi: 10.1016/j.apmr.2009.12.024.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。