BiVACOR® Total Artificial Heart Vroege haalbaarheidsstudie

24 september 2026 bijgewerkt door: BiVACOR Inc.

The purpose of this study is to assess the feasibility of using the BiVACOR Total Artificial Heart (TAH) System to support adult patients with severe biventricular heart failure, or univentricular heart failure in which left ventricular assist device (LVAD) support is not recommended, who require mechanical circulatory support to sustain life. The BiVACOR TAH System is intended for use as a bridge to transplant (BTT). Feasibility will be assessed by evaluating safety and performance of the BiVACOR TAH System in study subjects.

Studie Overzicht

Toestand

Werving

Interventie / Behandeling

Studietype

Ingrijpend

Inschrijving (Geschat)

20

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Contact Back-up

Studie Locaties

    • Arizona
      • Phoenix, Arizona, Verenigde Staten, 85006
    • North Carolina
      • Durham, North Carolina, Verenigde Staten, 27710
        • Werving
        • Duke University Hospital
        • Contact:
    • Ohio
    • Texas
      • Houston, Texas, Verenigde Staten, 77030
        • Werving
        • Texas Heart Institute / Baylor St. Luke's Medical Center
        • Contact:

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 70 jaar (Volwassen, Oudere volwassene)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • Patient has severe, irreversible biventricular heart failure and is eligible for biventricular mechanical circulatory support based on the International Society of Heart and Lung Transplantation (ISHLT) guidelines or has univentricular heart failure in which LVAD support is not recommended. ISHLT Guidelines for Biventricular Support:

    1. Biventricular failure with at least two of the following hemodynamic and/or echocardiographic measurements.

      1. Right ventricular ejection fraction (RVEF) ≤ 30%
      2. Right ventricular stroke work index (RVSWI) ≤ 0.25 g/m/beat/m2
      3. Tricuspid annular plane systolic excursion (TAPSE) ≤ 14 mm
      4. Right ventricular (RV) to left ventricular (LV) end-diastolic diameter ratio > 0.72
      5. Central venous pressure (CVP) > 15mmHg
      6. CVP to pulmonary capillary wedge pressure (PCWP) ratio > 0.63
      7. Tricuspid insufficiency grade 4
      8. Pulmonary artery pressure index (PAPi) < 2
    2. Treatment-refractory recurrent and sustained ventricular tachycardia or ventricular fibrillation in the presence of untreatable arrhythmogenic pathologic substrate.

    3. Heart failure due to restrictive or constrictive physiology (e.g., hypertrophic cardiomyopathy, cardiac amyloidosis/senile or other infiltrative heart disease).

  • Patient is categorized as INTERMACS Patient Profile Classification 2 or 3.

  • Patient is classified as NYHA Class IV.

  • Patient has a left ventricular ejection fraction (LVEF) ≤ 25%, with the exception of patients with restrictive or constrictive physiology.

  • Patient is inotrope dependent, OR has a cardiac index (CI) ≤ 2.2 L/min/m2 without inotropes if inotropes are contraindicated (e.g., restrictive or constrictive heart failure), and meets one of the following criteria:

    1. Is on optimal medical management (OMM), based on current heart failure practice guidelines for at least 45 out of the last 60 days and is failing to respond or is not able to tolerate OMM; or
    2. Has advanced heart failure for at least 14 days and is dependent on an intra-aortic balloon pump (IABP) or similar temporary mechanical circulatory support device (MCSD) for at least seven days.
  • Patient is eligible for cardiac transplantation as determined by the implanting center.

  • Patient has adequate room in the chest as determined by 3-D imaging or other standard clinical assessments.

  • Patient has read and understands the informed consent form (ICF) and has voluntarily provided informed consent.

Exclusion Criteria:

  • Patient has contraindications to anticoagulation or antiplatelet therapies.

  • Patient has coagulopathy defined by a platelet count < 50 k/µl.

  • Patient has insufficient space in the chest to accommodate the BiVACOR pump.

  • Patient has a body mass index (BMI) ≥ 35 kg/m2.

  • Patient is highly pre-sensitized prior to pump implantation.

  • Patient is unconscious and unresponsive.

  • Patient is on pre-implant extracorporeal membrane oxygenation (ECMO) for > 7 days.

  • Patient is on pre-implant temporary MCSD for more than 21 days [e.g., Intra-aortic balloon pump (IABP), Impella, CentriMag, etc.] unless ambulatory and free from adverse effects associated with the MCSD.

  • Patient is implanted with durable mechanical circulatory support (LVAD or RVAD).

  • Patient experienced cerebrovascular accident (CVA) within three months of eligibility evaluation.

  • Patient has severe end-organ dysfunction as evidenced by:

    1. Total bilirubin > 4.0 mg/dL or cirrhosis confirmed by imaging or positive biopsy, and/or
    2. Glomerular filtration rate (GFR) < 30 mL/min/1.73 m2 or renal replacement therapy dependence.
  • Patient has severe chronic obstructive pulmonary disease (COPD) or restrictive lung disease requiring home oxygen.

  • Patient has primary pulmonary hypertension ≥ 8 Wood units.

  • Patient has severe systemic light-chain amyloidosis.

  • Patient has been diagnosed with severe cardiac cachexia or irreversible frailty.

  • Patient has diabetes with advanced diabetic neuropathy with accompanying skin ulceration.

  • Patient has a blood-borne infection within seven days of eligibility evaluation. Positive blood cultures reflective of contaminants (e.g., Staphylococcus epidermidis) will not be considered an exclusion.

  • Patient is pregnant or planning pregnancy.

  • Patient has a co-morbidity or illness that would limit survival to less than two years.

  • Patient has a current drug and/or alcohol addiction or known substance abuse.

  • Patient has insufficient social support or a history of non-compliance with medical instructions as determined by the Investigator.

  • Patient is participating in another clinical trial that may impact or confound the results of the BiVACOR TAH EFS.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Toestel Haalbaarheid
  • Toewijzing: NVT
  • Interventioneel model: Opdracht voor een enkele groep
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Experimenteel: BiVACOR TAH

The BiVACOR TAH System will be implanted as a bridge to transplant (BTT) for adults with severe irreversible biventricular heart failure or univentricular heart failure in which LVAD support is not recommended, and who are eligible for cardiac transplantation.

The BiVACOR pump is an implantable rotary biventricular blood pump that uses magnetic levitation technology for increased durability to replace both ventricles of a failing heart. The device is intended to replace the diseased heart in patients suffering from heart failure to bridge the time to heart transplant.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Feasibility Endpoint
Tijdsspanne: 6 months or time of heart transplant (if prior to 6 months post pump implant)

Survival on the original BiVACOR pump

6 months or time of heart transplant (if prior to 6 months post pump implant)
Safety Endpoint
Tijdsspanne: Through 6 months

Evaluation of the safety of the BiVACOR TAH System using INTERMACS adverse event (AE) terms and definitions (INTERMACS Manual of Operations Version 5).

Through 6 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Sponsor

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

26 juni 2024

Primaire voltooiing (Geschat)

1 december 2026

Studie voltooiing (Geschat)

1 maart 2027

Studieregistratiedata

Eerst ingediend

8 december 2023

Eerst ingediend dat voldeed aan de QC-criteria

8 december 2023

Eerst geplaatst (Werkelijk)

18 december 2023

Updates van studierecords

Laatste update geplaatst (Werkelijk)

28 september 2026

Laatste update ingediend die voldeed aan QC-criteria

24 september 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Aanvullende relevante MeSH-voorwaarden

Andere studie-ID-nummers

  • CP-0001

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Ja

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .