- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07511153
Heeft de Cervicale Stenose Invloed op de Handfunctie?
Heeft de mate van cervicale spinale stenose invloed op de handfunctie?
The cervical spine is a complex structure that supports the weight of the head and protects the spinal cord and nerve roots. Cervical spinal stenosis (CSS), which develops as a result of degenerative processes, can cause narrowing of the spinal canal and compression of nerve structures, leading to symptoms such as pain, numbness, and weakness. This condition can negatively affect hand function, particularly grip strength and dexterity. However, studies in the literature examining the effect of CSS on grip strength and hand function are limited. Therefore, this study will be conducted to determine the effect of the severity of cervical spinal stenosis, identified in patients who underwent MRI following their presentation with cervical problems at the Physical Medicine and Rehabilitation outpatient clinic of Buca Seyfi Demirsoy Training and Research Hospital, İzmir Democracy University, on hand grip strength and functionality. Grip strength will be assessed using the Jamar hand dynamometer, and fine pinch strength will be evaluated using the Lafayette pinch meter. Additionally, hand functionality will be measured using the Nine-Hole Peg Test. The impact of neck pain on daily life will be assessed using the Neck Disability Index. The data obtained will be compared and analyzed using appropriate statistical methods.
This study is expected to fill a significant gap in the current literature by comprehensively elucidating the effects of cervical stenosis on hand function and grip performance, thereby contributing to the individualization of rehabilitation approaches.
Studie Overzicht
Toestand
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
-
Izmir, Turkije (Türkiye)
- Izmir Democracy University
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
The sample for this study will consist of individuals who presented to the Physical Medicine and Rehabilitation outpatient clinic at the Buca Seyfi Demirsoy Training and Research Hospital of Izmir Democracy University due to cervical problems and underwent cervical MRI. After obtaining informed consent, the individuals included in the study will undergo evaluation. First, participants will be grouped based on their cervical stenosis scores. The degree of cervical stenosis will be determined using MRIs that were previously requested and performed during various outpatient services. The evaluation of the MRI will be scored according to the Kang grading system for spinal stenosis. The Kang grading system includes four degrees ranging from 0 to 3 based on spinal cord compression.
Beschrijving
Inclusion Criteria:
- Individuals aged 18-75
- Individuals who have previously undergone a cervical MRI
- Cases where the degree of stenosis can be clearly determined on MRI
- Individuals who have had neck pain for at least 3 months
Exclusion Criteria:
- Individuals who declined to participate in the study
- Individuals who had undergone cervical surgery
- Individuals diagnosed with vertigo
- Individuals with sudden hearing loss
- Individuals with additional neurological conditions
- Individuals with psychiatric or cognitive disorders that would prevent measurement in the study
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: CASE_ONLY
- Tijdsperspectieven: CROSS_SECTIONAL
Cohorten en interventies
Groep / Cohort |
|---|
|
1
Group with Kang grade 0 |
|
2
Group with Kang grade 1 |
|
3
Group with Kang grade 2 |
|
4
Group with Kang grade 3 |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Hand Grip Strength
Tijdsspanne: Day 1
|
Hand grip strength will be assessed using a Jamar hydraulic hand dynamometer. Measurements will be taken while seated, with the arm positioned as follows: shoulder adduction, elbow at 90° flexion, and forearm in a neutral position. The wrist will be positioned at 0-30° extension and 0-15° ulnar deviation. The volunteer will be asked to grip the dynamometer firmly and squeeze as hard as possible. The measurements will be repeated three times, and the average value will be recorded in kilograms. |
Day 1
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Pinch Strength
Tijdsspanne: Day 1
|
A Lafayette brand hydraulic pinch meter will be used for this measurement. Measurements will be taken in three ways: two-point, lateral, and three-point grips. For the two-point grip measurement, the subject will be asked to squeeze the pinch meter using the tips of their thumb and index finger. For the lateral grip measurement, the volunteer will be asked to squeeze the pinch meter using the middle of the distal phalanx of the thumb and the lateral part of the middle phalanx of the index finger. For the three-point grip measurement, the subject will be instructed to squeeze the pinch meter using the distal phalanges of the thumb, index finger, and middle finger. Measurements will be taken in the same position as the grip strength test, in accordance with the standard; three measurements will be taken for each grip type, and the average will be recorded in pounds (lb). |
Day 1
|
|
The Nine-Hole Peg Test
Tijdsspanne: Day 1
|
The participants' manual dexterity will be assessed using the Nine-Hole Peg Test, which has been proven to be valid and reliable. The test consists of nine identical holes spaced at equal intervals and nine matching pegs. The timer starts the moment the person first touches a peg to place it. The person will be asked to take the pegs from the box, place them in the holes as quickly as possible, and then remove them and return them to the box. The test will be conducted while the person is seated. The activity time will be recorded in seconds. |
Day 1
|
|
Neck Disability Index
Tijdsspanne: Day 1
|
The Neck Disability Index is an adaptation of the Oswestry Disability Index for the cervical region and is a widely used 10-item questionnaire for assessing cervical dysfunction and neck pain. Each item is scored between 0 (no disability) and 5 (complete disability). The total score ranges from 0 to 50; a higher score indicates greater functional limitation. The questionnaire has established validity and reliability in Turkish. |
Day 1
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- 2026/25
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Beschrijving IPD-plan
Individual participant data (IPD) will not be shared because the data contain potentially identifiable sensitive clinical information, and sharing was not covered in the original informed consent provided to participants. Additionally, institutional and national data protection regulations limit the transfer of raw, de-identified individual-level data outside the research team.
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .