Continuous Non-Invasive Measurement of Hemoglobin During Parturition
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Detaljert beskrivelse
Obstetric hemorrhage remains the leading cause of maternal death worldwide (2). The most common culprits are uterine atony, placental disorders, and delivery trauma. Current detection and management of hemorrhage is heavily based on clinical judgment and laboratory results. Interventions such as fluid resuscitation and blood transfusion are often initiated after a significant hemorrhage has already taken place. Early detection and treatment of this potentially life threatening obstetric complication is of upmost importance in the field of obstetrics. Traditional methods for assessing hemoglobin levels involve collecting the patient's blood and sending it to the laboratory for analysis via complete blood count (CBC). This involves a delay and often patients are continuing to hemorrhage while the CBC is being processed. Novel technology has recently been approved by the FDA, which can continuously assess hemoglobin levels via a non-invasive monitor. This device works as a pulse oximeter, which is placed on the index finger and uses infrared technology to estimate hemoglobin levels (1). Despite its validation and use in many patient populations such as trauma, neurosurgery and orthopedic surgery, data is lacking in an obstetric population. The investigator's hypothesis is that this device will enable clinicians detect hemorrhage early and initiate resuscitation such as fluid and/or blood transfusion before significant hemorrhage has taken place. This study will be a proof of concept prospective cohort study, in which the investigators will attempt to detect the association between intra-operative and postoperative continuous non-invasive hemoglobin monitoring and postpartum decrease in hemoglobin.
Women undergoing primary cesarean delivery after failed induction of labor or repeat cesarean delivery after failed TOLAC (trial of labor after cesarean delivery), will be eligible for participation in this study. Prior to cesarean, all patients will have a CBC drawn. Masimo non-invasive hemoglobin monitor will be placed on their finger during delivery and remain in place until discharge from the recovery room. All patients will have CBC drawn on post operative day 1, as is the standard of care at our institution. Based on the drop in hemoglobin from pre-op to post-op day 1, patients will be separated into quartiles. The quartile with the highest drop in hemoglobin will be the "cases" and compared to the remainder of the quartiles or "controls." In addition, values obtained from the non-invasive monitor will be compared to those obtained from CBC.
Studietype
Registrering (Faktiske)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiesteder
-
-
Texas
-
Galveston, Texas, Forente stater, 77555
- University of Texas Medical Branch
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
Tar imot friske frivillige
Kjønn som er kvalifisert for studier
Beskrivelse
Inclusion Criteria:
- Pregnant women undergoing primary cesarean delivery after failed induction of labor, or repeat cesarean delivery after failed TOLAC (trial of labor after cesarean)
- Pregnant women between the ages of 18-50
Exclusion Criteria:
- Patient who are not pregnant
- Patients unwilling or unable to provide consent
- Patients under the age of 18
- Patients who are incarcerated
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Diagnostisk
- Tildeling: N/A
- Intervensjonsmodell: Enkeltgruppeoppdrag
- Masking: Ingen (Open Label)
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Annen: All Participants
All patients who agree to participate in the study will have the Masimo Rainbow Pulse CO-Oximeter non-invasive hemoglobin monitor placed on their finger during cesarean delivery.
A CBC will be drawn immediately prior to delivery and this value will be compared to the values obtained from the monitor.
The patients will be separated into quartiles based on total drop in hemoglobin (pre-op to post-op day 1) and the values from the monitor compared between quartiles.
|
Masimo Rainbow Pulse CO-oximeter will be used to measure hemoglobin values of pregnant women during primary cesarean delivery
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Pearson Correlation Coefficient for Hemoglobin Measurements
Tidsramme: 1 day post partum
|
Pearson Correlation Coefficient for hemoglobin measurements (Difference in Hemoglobin blood counts in g/dL between preop and post operative levels) obtained from blood draw to those obtained from the monitor
|
1 day post partum
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Number of Participants Who Required Blood Transfusion
Tidsramme: 0-5 days post partum
|
The rates in percentage of patients that received transfusion of packed red blood cells.
|
0-5 days post partum
|
Samarbeidspartnere og etterforskere
Etterforskere
- Hovedetterforsker: Katherine H Jelliffe, MD, University of Texas
- Studieleder: Antonio F Saad, MD, University of Texas
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Faktiske)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- 17-0087
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
produkt produsert i og eksportert fra USA
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .
Kliniske studier på Masimo Rainbow Pulse CO-oximeter
-
Children's Hospital of PhiladelphiaChildren's Anesthesiology Associates, Ltd.FullførtSkoliose | Spinal FusjonForente stater
-
University of Alabama at BirminghamOridionFullførtKomfort for åndedrettsapparatForente stater
-
Trakya UniversityFullførtPerfusjonsindeks | En-lunge ventilasjon | Hypoksemi under kirurgi | Oksygenreserveindeks | Pleth VariabilitetsindeksTyrkia
-
Selcuk UniversityFullførtAnemi (diagnose)Tyrkia (Türkiye)
-
University Hospital, ToursFullførtKarbonmonoksidforgiftningFrankrike
-
Samsun Education and Research HospitalFullført
-
Antalya Training and Research HospitalFullført
-
Cairo UniversityFullført
-
George Washington UniversityFullført