Continuous Non-Invasive Measurement of Hemoglobin During Parturition
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Detaillierte Beschreibung
Obstetric hemorrhage remains the leading cause of maternal death worldwide (2). The most common culprits are uterine atony, placental disorders, and delivery trauma. Current detection and management of hemorrhage is heavily based on clinical judgment and laboratory results. Interventions such as fluid resuscitation and blood transfusion are often initiated after a significant hemorrhage has already taken place. Early detection and treatment of this potentially life threatening obstetric complication is of upmost importance in the field of obstetrics. Traditional methods for assessing hemoglobin levels involve collecting the patient's blood and sending it to the laboratory for analysis via complete blood count (CBC). This involves a delay and often patients are continuing to hemorrhage while the CBC is being processed. Novel technology has recently been approved by the FDA, which can continuously assess hemoglobin levels via a non-invasive monitor. This device works as a pulse oximeter, which is placed on the index finger and uses infrared technology to estimate hemoglobin levels (1). Despite its validation and use in many patient populations such as trauma, neurosurgery and orthopedic surgery, data is lacking in an obstetric population. The investigator's hypothesis is that this device will enable clinicians detect hemorrhage early and initiate resuscitation such as fluid and/or blood transfusion before significant hemorrhage has taken place. This study will be a proof of concept prospective cohort study, in which the investigators will attempt to detect the association between intra-operative and postoperative continuous non-invasive hemoglobin monitoring and postpartum decrease in hemoglobin.
Women undergoing primary cesarean delivery after failed induction of labor or repeat cesarean delivery after failed TOLAC (trial of labor after cesarean delivery), will be eligible for participation in this study. Prior to cesarean, all patients will have a CBC drawn. Masimo non-invasive hemoglobin monitor will be placed on their finger during delivery and remain in place until discharge from the recovery room. All patients will have CBC drawn on post operative day 1, as is the standard of care at our institution. Based on the drop in hemoglobin from pre-op to post-op day 1, patients will be separated into quartiles. The quartile with the highest drop in hemoglobin will be the "cases" and compared to the remainder of the quartiles or "controls." In addition, values obtained from the non-invasive monitor will be compared to those obtained from CBC.
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
Texas
-
Galveston, Texas, Vereinigte Staaten, 77555
- University of Texas Medical Branch
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Pregnant women undergoing primary cesarean delivery after failed induction of labor, or repeat cesarean delivery after failed TOLAC (trial of labor after cesarean)
- Pregnant women between the ages of 18-50
Exclusion Criteria:
- Patient who are not pregnant
- Patients unwilling or unable to provide consent
- Patients under the age of 18
- Patients who are incarcerated
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Diagnose
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Sonstiges: All Participants
All patients who agree to participate in the study will have the Masimo Rainbow Pulse CO-Oximeter non-invasive hemoglobin monitor placed on their finger during cesarean delivery.
A CBC will be drawn immediately prior to delivery and this value will be compared to the values obtained from the monitor.
The patients will be separated into quartiles based on total drop in hemoglobin (pre-op to post-op day 1) and the values from the monitor compared between quartiles.
|
Masimo Rainbow Pulse CO-oximeter will be used to measure hemoglobin values of pregnant women during primary cesarean delivery
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Pearson Correlation Coefficient for Hemoglobin Measurements
Zeitfenster: 1 day post partum
|
Pearson Correlation Coefficient for hemoglobin measurements (Difference in Hemoglobin blood counts in g/dL between preop and post operative levels) obtained from blood draw to those obtained from the monitor
|
1 day post partum
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Number of Participants Who Required Blood Transfusion
Zeitfenster: 0-5 days post partum
|
The rates in percentage of patients that received transfusion of packed red blood cells.
|
0-5 days post partum
|
Mitarbeiter und Ermittler
Ermittler
- Hauptermittler: Katherine H Jelliffe, MD, University of Texas
- Studienleiter: Antonio F Saad, MD, University of Texas
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- 17-0087
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .
Klinische Studien zur Masimo Rainbow Pulse CO-oximeter
-
Children's Hospital of PhiladelphiaChildren's Anesthesiology Associates, Ltd.AbgeschlossenSkoliose | WirbelsäulenfusionVereinigte Staaten
-
Trakya UniversityAbgeschlossenDurchblutungsindex | Ein-Lungen-Beatmung | Hypoxämie während der Operation | Sauerstoffreserveindex | Pleth-VariabilitätsindexTruthahn
-
Suleyman Demirel UniversityAbgeschlossen
-
Cairo UniversityAbgeschlossenAngeborenen HerzfehlerÄgypten
-
George Washington UniversityAbgeschlossen
-
Samsun Education and Research HospitalAbgeschlossenAllgemeine AnästhesieTruthahn
-
Kasr El Aini HospitalUnbekannt
-
Antalya Training and Research HospitalAbgeschlossenKaiserschnitt-KomplikationenTruthahn
-
Cairo UniversityAbdelhamid, Bassant Mohamed, M.D.; Mohamed, Ahmed A., M.D.; Ashraf Mohamed Abd... und andere MitarbeiterAbgeschlossenMasimo Radical Puls Co-Oximeter in der intraoperativen Bluttransfusionspraxis während geburtshilflicher EingriffeÄgypten
-
University of Alabama at BirminghamOridionAbgeschlossenKomfort von BeatmungsgerätenVereinigte Staaten