- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT03150043
Continuous Non-Invasive Measurement of Hemoglobin During Parturition
Tutkimuksen yleiskatsaus
Tila
Ehdot
Interventio / Hoito
Yksityiskohtainen kuvaus
Obstetric hemorrhage remains the leading cause of maternal death worldwide (2). The most common culprits are uterine atony, placental disorders, and delivery trauma. Current detection and management of hemorrhage is heavily based on clinical judgment and laboratory results. Interventions such as fluid resuscitation and blood transfusion are often initiated after a significant hemorrhage has already taken place. Early detection and treatment of this potentially life threatening obstetric complication is of upmost importance in the field of obstetrics. Traditional methods for assessing hemoglobin levels involve collecting the patient's blood and sending it to the laboratory for analysis via complete blood count (CBC). This involves a delay and often patients are continuing to hemorrhage while the CBC is being processed. Novel technology has recently been approved by the FDA, which can continuously assess hemoglobin levels via a non-invasive monitor. This device works as a pulse oximeter, which is placed on the index finger and uses infrared technology to estimate hemoglobin levels (1). Despite its validation and use in many patient populations such as trauma, neurosurgery and orthopedic surgery, data is lacking in an obstetric population. The investigator's hypothesis is that this device will enable clinicians detect hemorrhage early and initiate resuscitation such as fluid and/or blood transfusion before significant hemorrhage has taken place. This study will be a proof of concept prospective cohort study, in which the investigators will attempt to detect the association between intra-operative and postoperative continuous non-invasive hemoglobin monitoring and postpartum decrease in hemoglobin.
Women undergoing primary cesarean delivery after failed induction of labor or repeat cesarean delivery after failed TOLAC (trial of labor after cesarean delivery), will be eligible for participation in this study. Prior to cesarean, all patients will have a CBC drawn. Masimo non-invasive hemoglobin monitor will be placed on their finger during delivery and remain in place until discharge from the recovery room. All patients will have CBC drawn on post operative day 1, as is the standard of care at our institution. Based on the drop in hemoglobin from pre-op to post-op day 1, patients will be separated into quartiles. The quartile with the highest drop in hemoglobin will be the "cases" and compared to the remainder of the quartiles or "controls." In addition, values obtained from the non-invasive monitor will be compared to those obtained from CBC.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Vaihe
- Ei sovellettavissa
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Texas
-
Galveston, Texas, Yhdysvallat, 77555
- University of Texas Medical Branch
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Kuvaus
Inclusion Criteria:
- Pregnant women undergoing primary cesarean delivery after failed induction of labor, or repeat cesarean delivery after failed TOLAC (trial of labor after cesarean)
- Pregnant women between the ages of 18-50
Exclusion Criteria:
- Patient who are not pregnant
- Patients unwilling or unable to provide consent
- Patients under the age of 18
- Patients who are incarcerated
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
- Ensisijainen käyttötarkoitus: Diagnostiikka
- Jako: Ei käytössä
- Inventiomalli: Yksittäinen ryhmätehtävä
- Naamiointi: Ei mitään (avoin tarra)
Aseet ja interventiot
Osallistujaryhmä / Arm |
Interventio / Hoito |
|---|---|
|
Muut: All Participants
All patients who agree to participate in the study will have the Masimo Rainbow Pulse CO-Oximeter non-invasive hemoglobin monitor placed on their finger during cesarean delivery.
A CBC will be drawn immediately prior to delivery and this value will be compared to the values obtained from the monitor.
The patients will be separated into quartiles based on total drop in hemoglobin (pre-op to post-op day 1) and the values from the monitor compared between quartiles.
|
Masimo Rainbow Pulse CO-oximeter will be used to measure hemoglobin values of pregnant women during primary cesarean delivery
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Pearson Correlation Coefficient for Hemoglobin Measurements
Aikaikkuna: 1 day post partum
|
Pearson Correlation Coefficient for hemoglobin measurements (Difference in Hemoglobin blood counts in g/dL between preop and post operative levels) obtained from blood draw to those obtained from the monitor
|
1 day post partum
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Number of Participants Who Required Blood Transfusion
Aikaikkuna: 0-5 days post partum
|
The rates in percentage of patients that received transfusion of packed red blood cells.
|
0-5 days post partum
|
Yhteistyökumppanit ja tutkijat
Tutkijat
- Päätutkija: Katherine H Jelliffe, MD, University of Texas
- Opintojohtaja: Antonio F Saad, MD, University of Texas
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- 17-0087
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Yhdysvalloissa valmistettu ja sieltä viety tuote
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .
Kliiniset tutkimukset Masimo Rainbow Pulse CO-oximeter
-
Antalya Training and Research HospitalValmisKeisarileikkauksen komplikaatiotTurkki
-
Masimo CorporationValmis
-
Cairo UniversityAbdelhamid, Bassant Mohamed, M.D.; Mohamed, Ahmed A., M.D.; Ashraf Mohamed... ja muut yhteistyökumppanitValmisMasimo-radikaalipulssi-kooksimetri leikkauksensisäisessä verensiirrossa synnytystoimenpiteen aikanaEgypti
-
Children's Hospital of PhiladelphiaChildren's Anesthesiology Associates, Ltd.ValmisSkolioosi | Spinal FusionYhdysvallat
-
University of EdinburghNHS Lothian; Prism Training and Consultancy; Simpsons Special Care BabiesAktiivinen, ei rekrytointiVastasyntyneen enkefalopatia | Ennenaikainen vauvan sairaus | Vastasyntyneen hypoksinen iskeeminen enkefalopatiaYhdistynyt kuningaskunta
-
Trakya UniversityValmisPerfuusioindeksi | Yhden keuhkon ilmanvaihto | Hypoksemia leikkauksen aikana | Happivaraindeksi | Pleth Variability IndexTurkki
-
Stony Brook UniversityValmisRaskauden, synnytyksen ja synnytyksen komplikaatiotYhdysvallat
-
University of Alabama at BirminghamOridionValmisHengityslaitteen mukavuusYhdysvallat
-
Selcuk UniversityValmisAnemia (diagnoosi)Turkki (Türkiye)
-
Mespere Lifesciences Inc.ValmisTerveet vapaaehtoisetYhdysvallat