Innledende korreksjon Keratokonus

9. november 2026 oppdatert av: University of Illinois Chicago

Innledende korreksjon Keratokonus: skleral vs hornhinnegass-permeable linser SCOPE-studie

Keratoconus is a non-inflammatory, progressive disease in which corneal irregularity increases. As the condition develops, more advanced forms of optical correction are needed to improve vision for patients. Until recently, small diameter corneal gas permeable lenses were considered the primary mode of correction for patients with keratoconus. Now, however, practitioners have multiple options for reducing the optical aberrations caused by keratoconus, including scleral lenses. As of yet, no single option for optical correction has been identified as the preferred mode of correction in terms of overall patient satisfaction with vision, comfort, and ease of use. The order in which various forms of optical correction would be most logically introduced has yet to be determined. This is a study comparing small diameter corneal gas permeable and large diameter scleral lenses in individuals with keratoconus.

This study will prospectively compare visual satisfaction and ease of use between corneal gas permeable and scleral lenses for patients with mild to moderate keratoconus.

Studieoversikt

Status

Fullført

Forhold

Intervensjon / Behandling

Detaljert beskrivelse

While both corneal gas permeable and scleral lenses have been show to improve visual acuity in individuals with keratoconus, it has yet to be determined if one option has superior comfort and overall patient satisfaction in patients new to gas permeable lens use. In this study, patients will be prospectively fit with both corneal gas permeable and scleral lenses according to standard clinical practice. Both corneal gas permeable and scleral lenses are considered standard of care for patients with keratoconus.

The investigators hypothesize that study participants will select scleral lens over corneal gas permeable lens as their preferred final lens type of choice.

The Primary outcome measure of this study is participant selected final lens choice for continued use for the management of keratoconus.

Methods:

Study Design This is a prospective, multi-center, randomized interventional clinical trial with a 2x2 crossover design of patients with keratoconus fit with corneal and scleral gas permeable contact lenses. The crossover design allows intra-subject differences between two randomized groups with participants serving as their own controls. Contact lens #1 will be the SynergEyes VS (Synergeyes, Inc., Carlsbad CA) which features bi-tangential toric peripheries with linear landing zones. The standard lens is 16.0mm and is available from 14.5 to 17.5mm diameters. Contact lens #2 will be the RoseK2 corneal gas permeable lens (Blanchard Contact Lens, Inc. Manchester, NH). The lens is available in with a base curve range from 4.30 to 8.60 mm, diameter of 7.90 to 10.40mm.

Inclusion Criteria

  • Age 18 or older.
  • Diagnosis of keratoconus.
  • Available baseline corneal topography and pachymetry
  • Amsler-Krumeich keratoconus classification of stage 1 or higher

Exclusion Criteria

  • No prior corneal transplantation or INTACTS
  • No prior use of hybrid, corneal or scleral gas permeable lenses
  • Presence of corneal scarring

Study procedures During the initial study visits patient demographics, past ocular and medical history and best corrected visual acuity with manifest refraction will be recorded. Additional testing may include corneal topography, pachymetry and meibography. Dry eye symptoms and contact lens comfort will be assessed using the OSDI and CLDEQ questionnaires.

Participants will be fit according to standard practices with the RoseK 2 corneal gas permeable and Synergeyes VS scleral lenses following manufacturer's recommendations. Over refraction and best corrected visual acuity will be recorded. Subjective comfort with lens use rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

Participants will be randomized to dispense lens #1 vs lens #2. They will be trained in safe application and removal and provided instructions on lens disinfection procedures. Best corrected visual acuity with lens #1 and subjective comfort with lens use will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

At the next visit, participants will return wearing lens #1 for minimum of 3 hours. Best corrected visual acuity with lens #1 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

At the final visit, participants will return wearing lens #2 for minimum of 3 hours. Best corrected visual acuity with lens #2 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).

The participant will make a final selection of lens of choice #1 or #2.

Studietype

Intervensjonell

Registrering (Faktiske)

32

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Illinois
      • Chicago, Illinois, Forente stater, 60616
        • Illinois Eye Institute
      • Chicago, Illinois, Forente stater, 60612
        • University of Illinois at Chicago Eye and Ear Infirmary
    • Minnesota
      • Rochester, Minnesota, Forente stater, 55905
        • Mayo Clinic
    • Ohio
      • Columbus, Ohio, Forente stater, 43210
        • The Ohio State University College of Optometry

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Diagnosis of keratoconus
  • Available baseline corneal topography and pachymetry
  • Amsler-Krumeich keratoconus classification9 of stage 1

Exclusion Criteria:

  • No prior corneal transplantation or INTACTS
  • No prior use of hybrid, corneal or scleral gas permeable lenses
  • Presence of corneal scarring.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Annen
  • Tildeling: Randomisert
  • Intervensjonsmodell: Crossover-oppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Aktiv komparator: Corneal gas permeable lens first

Device: corneal gas permeable contact lenses (RoseK2 corneal Blanchard Contact Lens, Inc. Manchester, NH).

Participants with an odd study ID will be fit with the corneal gas permeable lens first.

Fit in corneal gas permeable contact lens first.

Aktiv komparator: Scleral lens first

Device: scleral lenses (SynergEyes VS (Synergeyes, Inc., Carlsbad CA).

Participants with an even study ID will be fit with the scleral lens first.

Fit in corneal gas permeable contact lens first.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Final contact lens choice
Tidsramme: At study completion (6-24 weeks)

Each study participant will select whether to continue with Lens 1 or Lens 2. The percentage of those who choose a Scleral Lens will be compared to the percentage of participants who select corneal gas permeable lenses.

At study completion (6-24 weeks)

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Subjective comfort with lens use
Tidsramme: Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)

Subjective comfort with lens use will be rated by participants on comfort scale of 0 (not comfortable) to 10 (very comfortable).

Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Ellen S Shorter, OD, University of Illinois Chicago

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

23. juli 2021

Primær fullføring (Faktiske)

15. mai 2026

Studiet fullført (Faktiske)

15. mai 2026

Datoer for studieregistrering

Først innsendt

14. mai 2021

Først innsendt som oppfylte QC-kriteriene

4. juni 2021

Først lagt ut (Faktiske)

8. juni 2021

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

13. november 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

9. november 2026

Sist bekreftet

1. mai 2026

Mer informasjon

Begreper knyttet til denne studien

Ytterligere relevante MeSH-vilkår

Andre studie-ID-numre

  • 2020-1504

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

produkt produsert i og eksportert fra USA

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .