初步矫正圆锥角膜
初始矫正圆锥角膜:巩膜与角膜透气镜片 SCOPE 研究
Keratoconus is a non-inflammatory, progressive disease in which corneal irregularity increases. As the condition develops, more advanced forms of optical correction are needed to improve vision for patients. Until recently, small diameter corneal gas permeable lenses were considered the primary mode of correction for patients with keratoconus. Now, however, practitioners have multiple options for reducing the optical aberrations caused by keratoconus, including scleral lenses. As of yet, no single option for optical correction has been identified as the preferred mode of correction in terms of overall patient satisfaction with vision, comfort, and ease of use. The order in which various forms of optical correction would be most logically introduced has yet to be determined. This is a study comparing small diameter corneal gas permeable and large diameter scleral lenses in individuals with keratoconus.
This study will prospectively compare visual satisfaction and ease of use between corneal gas permeable and scleral lenses for patients with mild to moderate keratoconus.
研究概览
详细说明
While both corneal gas permeable and scleral lenses have been show to improve visual acuity in individuals with keratoconus, it has yet to be determined if one option has superior comfort and overall patient satisfaction in patients new to gas permeable lens use. In this study, patients will be prospectively fit with both corneal gas permeable and scleral lenses according to standard clinical practice. Both corneal gas permeable and scleral lenses are considered standard of care for patients with keratoconus.
The investigators hypothesize that study participants will select scleral lens over corneal gas permeable lens as their preferred final lens type of choice.
The Primary outcome measure of this study is participant selected final lens choice for continued use for the management of keratoconus.
Methods:
Study Design This is a prospective, multi-center, randomized interventional clinical trial with a 2x2 crossover design of patients with keratoconus fit with corneal and scleral gas permeable contact lenses. The crossover design allows intra-subject differences between two randomized groups with participants serving as their own controls. Contact lens #1 will be the SynergEyes VS (Synergeyes, Inc., Carlsbad CA) which features bi-tangential toric peripheries with linear landing zones. The standard lens is 16.0mm and is available from 14.5 to 17.5mm diameters. Contact lens #2 will be the RoseK2 corneal gas permeable lens (Blanchard Contact Lens, Inc. Manchester, NH). The lens is available in with a base curve range from 4.30 to 8.60 mm, diameter of 7.90 to 10.40mm.
Inclusion Criteria
- Age 18 or older.
- Diagnosis of keratoconus.
- Available baseline corneal topography and pachymetry
- Amsler-Krumeich keratoconus classification of stage 1 or higher
Exclusion Criteria
- No prior corneal transplantation or INTACTS
- No prior use of hybrid, corneal or scleral gas permeable lenses
- Presence of corneal scarring
Study procedures During the initial study visits patient demographics, past ocular and medical history and best corrected visual acuity with manifest refraction will be recorded. Additional testing may include corneal topography, pachymetry and meibography. Dry eye symptoms and contact lens comfort will be assessed using the OSDI and CLDEQ questionnaires.
Participants will be fit according to standard practices with the RoseK 2 corneal gas permeable and Synergeyes VS scleral lenses following manufacturer's recommendations. Over refraction and best corrected visual acuity will be recorded. Subjective comfort with lens use rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
Participants will be randomized to dispense lens #1 vs lens #2. They will be trained in safe application and removal and provided instructions on lens disinfection procedures. Best corrected visual acuity with lens #1 and subjective comfort with lens use will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
At the next visit, participants will return wearing lens #1 for minimum of 3 hours. Best corrected visual acuity with lens #1 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
At the final visit, participants will return wearing lens #2 for minimum of 3 hours. Best corrected visual acuity with lens #2 will be recorded as well as hours of lens wear today, average hours of lens wear time, days per week of per week and daily time spent on lens application and removal. They will rate subjective comfort with lens use on comfort scale of 0 (not comfortable) to 10 (very comfortable). Dry eye symptoms will be assessed using OSDI and CLDEQ questionnaires. Participants will be trained in application and removal with lens #2. Best corrected visual acuity with lens #2 and subjective comfort will be rated on comfort scale of 0 (not comfortable) to 10 (very comfortable).
The participant will make a final selection of lens of choice #1 or #2.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Illinois
-
Chicago、Illinois、美国、60616
- Illinois Eye Institute
-
Chicago、Illinois、美国、60612
- University of Illinois at Chicago Eye and Ear Infirmary
-
-
Minnesota
-
Rochester、Minnesota、美国、55905
- Mayo Clinic
-
-
Ohio
-
Columbus、Ohio、美国、43210
- The Ohio State University College of Optometry
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Diagnosis of keratoconus
- Available baseline corneal topography and pachymetry
- Amsler-Krumeich keratoconus classification9 of stage 1
Exclusion Criteria:
- No prior corneal transplantation or INTACTS
- No prior use of hybrid, corneal or scleral gas permeable lenses
- Presence of corneal scarring.
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Corneal gas permeable lens first
Device: corneal gas permeable contact lenses (RoseK2 corneal Blanchard Contact Lens, Inc. Manchester, NH). Participants with an odd study ID will be fit with the corneal gas permeable lens first. |
Fit in corneal gas permeable contact lens first. |
|
有源比较器:Scleral lens first
Device: scleral lenses (SynergEyes VS (Synergeyes, Inc., Carlsbad CA). Participants with an even study ID will be fit with the scleral lens first. |
Fit in corneal gas permeable contact lens first. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Final contact lens choice
大体时间:At study completion (6-24 weeks)
|
Each study participant will select whether to continue with Lens 1 or Lens 2. The percentage of those who choose a Scleral Lens will be compared to the percentage of participants who select corneal gas permeable lenses. |
At study completion (6-24 weeks)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Subjective comfort with lens use
大体时间:Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)
|
Subjective comfort with lens use will be rated by participants on comfort scale of 0 (not comfortable) to 10 (very comfortable). |
Baseline, Study Visit 1 (2-4 weeks), Study Visit 2 (4-10 weeks) and at study completion (6-24 weeks)
|
合作者和调查者
调查人员
- 首席研究员:Ellen S Shorter, OD、University of Illinois Chicago
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.