Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Total versus robotassistert enkompartmental kneerstatning (TRAKER)

22. september 2026 oppdatert av: NHS Lothian

Total versus robotassistert enkompartmentell kneerstatning (TRAKER) for medial kompartmentartrose: randomisert kontrollert forsøk

The purpose of this research is to compare the functional outcomes of patients with end stage medial compartment OA of the knee undergoing a conventional mTKA to those undergoing rUKA and to assess the associated cost economics of such technology.

Studieoversikt

Detaljert beskrivelse

Unicompartmental knee arthroplasty (UKA) is an accepted surgical alternative to total knee arthroplasty (TKA) for patients with isolated medial compartmental joint disease with the potential advantages of accelerated recovery, improved functional outcomes and retention of anatomical knee kinematics. However, some surgeons continue to favour TKA over UKA due to a lower revision rate. The higher revision rates associated with UKA are thought to be primarily due to component malpositioning and postoperative limb malalignment.

Robotic-arm assisted (r)UKA offers a greater level of precision of component positioning compared to manual UKA and more recently the survivorship of rUKA has been shown to be greater than manual UKA. Early functional outcomes following robotic UKA appear to be better than those observed after manual TKA. Therefore, the benefits of UKA could potentially be enjoyed by the patient without the increased risk of revision when compared to TKA for those with medical compartment disease.

The primary aim of this study is to compare the early knee specific functional outcome of rUKA with manually performed (m)TKA when performed for patients with medial compartment osteoarthritis of the knee.

A single centre randomised control trial will be carried out powered to the Oxford knee score.

Studietype

Intervensjonell

Registrering (Antatt)

159

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studer Kontakt Backup

Studiesteder

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

50 år til 75 år (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Listed for elective primary TKA for end stage medial compartment osteoarthritis
  • Intact anterior cruciate ligament
  • Full thickness and good quality lateral cartilage
  • Correctable intra-articular varus deformity and intact medial collateral ligament
  • American Society of Anesthesiologists (ASA) grades 1 and 2
  • Male or female, age 50 - 75 at the time of listing for surgery
  • Suitable candidate for a cruciate retaining TKA (Triathlon prosthesis) and a UKA

Exclusion Criteria:

  • Varus deformity of > 20 degrees
  • Fixed flexion of >10 degrees
  • Patient is unable to comply with the study protocol (incl. refusal for CT scan) or functional assessments
  • Female participants who are pregnant, lactating or planning pregnancy during the course of the study
  • Requires patella resurfacing or lateral compartment has significant OA
  • Inability to understand the patient information for the study, provide written informed consent or answer study questionnaires for cognitive or language reasons
  • Inflammatory disorder e.g. rheumatoid arthritis
  • Symptomatic foot, hip or spine pathology
  • Prior surgery (other than arthroscopy) or septic arthritis of the knee
  • Any other significant disease or disorder which, in the opinion of the Investigator, may either put the participants at risk because of participation in the study,

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Dobbelt

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Aktiv komparator: Manual Total Knee Arthroplasty

This group will receive a conventional manual Triathlon (Stryker) TKA with a cruciate retaining polyethylene insert. The surgeon will then make bone cuts using a manual jig and a hand held saw to prepare the bone surfaces for the implant. A measured resection technique will be employed with a three degree tibial slope. The surgeon will use a conventional jig alignment technique for intramedullary referencing for the femur and extra medullary referencing for the tibia. Once the implant is in position the knee is then balanced by the "feel" though a range of movement and soft tissue releases will be performed as required to balance the knee in flexion and extension.

Triathlon (Stryker) TKA with a cruciate retaining polyethylene insert.

Andre navn:
  • Total kneerstatning
Eksperimentell: Robotic Assisted Unicompartmental Knee Arthroplasty

This group will receive the cemented Restoris MCK (Mako, Stryker) with a highly crossed linked (X3) polyethylene insert through a less invasive to the knee joint. Instead of using a manual jig and a hand held burr will be used to prepare the bone surfaces for the implant, the MAKO robotic arm will be used by the surgeon to cut the bone at the required alignment. The information from the CT scan will be used to create a 3D model of the patient's bony anatomy and will used to plan the positioning of the implant. Once the trackers are in place registration of the knee joint surface is performed. The specified bone cuts are then performed using the robotic arm, aiming to gap balance the knee through a full range of movement.

The robotic-arm will be used to position a partial knee arthroplasty.

Andre navn:
  • Robotarmassistert delvis kneartroplastikk

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Oxford knee score
Tidsramme: Baseline to 6 months

Knee specific functional outcome measure. It consists of twelve questions assessed on a Likert scale with values from 0 to 4, to give a summative score. This is measured on a scale from 0 (worst) to 48 (best).

Baseline to 6 months

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Oxford knee score and Activity and Participation Questionnaire
Tidsramme: Baseline to 3, 6 and 12 months

The Oxford knee score is a knee specific functional outcome measure. It consists of twelve questions assessed on a Likert scale with values from 0 to 4, to give a summative score. This is measured on a scale from 0 (worst) to 48 (best). The additional Activity and Participation Questionnaire is a higher functioning supplementary questionnaire consisting of a further eight questions scored 0 (worst) to 4 (best).

Baseline to 3, 6 and 12 months
Forgotten Joint Score
Tidsramme: Baseline to 3, 6 and 12 months

Knee specific functional outcome. It uses a five-point Likert response format, consisting of 12 equally weighted questions with the raw score transformed to range from zero (worst) to 100 (best) points.

Baseline to 3, 6 and 12 months
Patient satisfaction
Tidsramme: 3, 6 and 12 months

Patient satisfaction will be assessed following surgery by asking four questions with a different focus:

i. "Overall how satisfied are you with the results of your knee replacement surgery?" ii. "How satisfied are you with the results of your knee replacement surgery for improving your ability to do housework or yard work (such as cooking, cleaning, or gardening and raking leaves)?" iii. "How satisfied are you with the results of your knee replacement surgery for improving your ability to do recreational activities (such as taking walks, swimming, bicycling, playing golf, dancing, going out with friends)?" iv. "How satisfied are you with the results of your knee replacement surgery for relieving your pain?" The response to each question will be recorded using a four point Likert scale: very satisfied, somewhat satisfied, somewhat dissatisfied, and very dissatisfied.

3, 6 and 12 months
EQ-5D-3L
Tidsramme: Baseline to 3, 6 and 12 months

Quality of life will be assessed using the EQ-5D-3L general health questionnaire which evaluates five domains (-5D), which include: mobility, self-care, usual activities, pain/discomfort, and anxiety/depression. This is a two page questionnaire that consists of five dimensions, with the responses recorded at three levels (3L) of severity (no problems; some problems or extreme problems). The utility index is on a scale of -0.594 to 1, where 1 represents perfect health and a negative value represents a state perceived as worse than death.

The second page consists of a standard vertical 20cm visual analogue scale (EQ-5D VAS) which is transformed to a scale of 0 (worst) to 100 (best) measuring current health-related quality of life. Each patient's health state, derived from the EQ-5D, will be measured before and after their surgery to determine the change in their health gain or loss after their knee replacement surgery.

Baseline to 3, 6 and 12 months
Range of movement
Tidsramme: Baseline to 3, 6 and 12 months

A goniometer will be used to measure range of movement by a blinded researcher prior to surgery (baseline), at discharge (immediately post surgery prior to discharge home) and at review appoints. Three measurements will be recorded for extension and flexion of the knee and an average will be documented.

Baseline to 3, 6 and 12 months
Cost effectiveness
Tidsramme: Baseline to 3, 6 and 12 months, and projected for the patients lifetime

Cost utility analysis will be undertaken to establish the incremental cost effectiveness ratio (ICER). Each patient's health state, derived from the EQ-5D, will be measured before and after their surgery to determine the change in their health gain or loss after their knee replacement surgery. The health state will then be multiplied by the time spent in that state to derive the QALYs gained or lost. The cost per QALY will then be calculated by dividing the cost of the procedure by the QALYs gained after total knee arthroplasty (intervention). A health service resource use questionnaire will be completed by the patient at the 3, 6 and 12 month research assessment. The questionnaire collects data on primary, secondary and community care and associated with the knee replacement over the previous months. Inpatient and surgical data will be collected on the case report forms (CRF's) and complications will be recorded at each visit.

Baseline to 3, 6 and 12 months, and projected for the patients lifetime
Knee stability and power
Tidsramme: Baseline to 3, 6 and 12 months

Knee stability (stress testing) and power (power rig) will be measured. A stress will be applied to the knee and the joint space opening will be measured using an ultrasound probe which will be used as a marker of knee stability. The power of the knee joint will be assessed using a standardise power rig Specific assessment of the patient's power output will be evaluated by a Leg Extensor Power Rig (Nottingham, UK), well validated for use with this population group.

Baseline to 3, 6 and 12 months
Patient expectation pre-operative and fulfilment
Tidsramme: Baseline to 3, 6 and 12 months

The Hospital of Special Surgery Expectation questionnaire is a validated measure of patient pre-operative expectations of surgery. The level of patient expectation is indicated on a 5 point Likert scale as 'very important', 'somewhat important', 'a little important', 'I do not expect this' or 'this does not apply to me'. After surgery patients will complete a similar expectation questionnaire, but are asked whether the same expectations had been fulfilled, which again is assessed on a 5 point Likert scale as: 'greatly', 'a lot', 'a little', 'I did not expect this' or 'this did not apply to me'.

Baseline to 3, 6 and 12 months

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Sponsor

Etterforskere

  • Hovedetterforsker: Nicholas D Clement, MD, PhD, NHS Lothian

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

26. august 2024

Primær fullføring (Antatt)

31. desember 2026

Studiet fullført (Antatt)

31. desember 2027

Datoer for studieregistrering

Først innsendt

16. februar 2022

Først innsendt som oppfylte QC-kriteriene

11. mars 2022

Først lagt ut (Faktiske)

22. mars 2022

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

23. september 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

22. september 2026

Sist bekreftet

1. september 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

IPD-planbeskrivelse

There is no plan to make individual patient data available.

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Ja

produkt produsert i og eksportert fra USA

Ja

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere