Medição da Temperatura do Gás Expiratório em Pacientes Intubados para Estimar a Humidade Absoluta Expiratória
Medição da Temperatura do Gás Expiratório em Doentes Intubados para Estimar a Humidade Absoluta Expiratória
Adequate humidification is essential for intubated patients because dry medical gases can cause thick secretions and dangerous endotracheal tube blockages. A clear correlation exists between exhaled and inhaled humidity delivered by heat and moisture exchanger. The objective of this study is to measure the temperature of exhaled gases in intubated patients in order to accurately calculate the absolute humidity during the expiratory phase. These data will allow for a more accurate reproduction of real clinical conditions during bench testing and will improve the assessment of heat and moisture exchanger performance device evaluation.
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
Previous clinical studies suggest that real expiratory humidity in intubated patients is close to 35 mg H₂O/L, with expiratory temperatures around 32-33 °C or slightly lower. However, data are limited, heterogeneous, and often derived from anesthetized patients. Therefore, accurate measurement of expiratory temperature in intensive care patients under normothermia and across varying body temperatures is necessary to define realistic simulation standards and ensure reliable heat and moisture exchanger performance evaluation on a bench. A relationship between expiratory gases temperature and expiratory humidity exist.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Contato de estudo
- Nome: Francois Lellouche, MD, PhD
- Número de telefone: 3572 1 418-656-8711
- E-mail: francois.lellouche@criucpq.ulaval.ca
Locais de estudo
-
-
Quebec
-
Québec, Quebec, Canadá, G1V4G5
- Recrutamento
- Insitut universitaire de cardiologie et de pneumologie de Quebec - Universite Laval
-
Contato:
- Francois Lellouche Principal Investigator
- Número de telefone: 3579 418-656-8711
- E-mail: francois.lellouche@criucpq.ulaval.ca
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Intubated patient using a heater and moist exchanger
Descrição
Inclusion Criteria:
- Adults (≥18 years)
- Intubated and mechanically ventilated in the intensive care unite
- Using passive humidification (Heat and Moisture exchanger)
Exclusion Criteria:
- PEEP set < 12 cmH₂O
- Inhaled nitric oxide therapy
- Tracheostomy
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Modelos de observação: COHORT
- Perspectivas de Tempo: PROSPECTIVE
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
Normothermic patient
Normothermic patient under mechanical ventilation with passive humification (heat and moisture exchanger) with body temperature between 36.0 and 38.0 Celsius degrees |
Measure expiratory gas temperature immediately before the passive humidifier in intubated ICU patients and evaluate the relationship between body temperature and expiratory temperature. |
|
Hypothermic patient
Hypothermic patient under mechanical ventilation with passive humification (heat and moisture exchanger) with body temperature < 36.0 Celsius degrees |
Measure expiratory gas temperature immediately before the passive humidifier in intubated ICU patients and evaluate the relationship between body temperature and expiratory temperature. |
|
Hyperthermic patient
Hyperthermic patient under mechanical ventilation with passive humification (heat and moisture exchanger) with body temperature > 38.0 Celsius degrees |
Measure expiratory gas temperature immediately before the passive humidifier in intubated ICU patients and evaluate the relationship between body temperature and expiratory temperature. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Expiratory gas temperature
Prazo: H0, up to 60 minutes after inclusion
|
Measure expiratory gas temperature immediately before the passive humidifier |
H0, up to 60 minutes after inclusion
|
|
Relationship between body temperature and expiratory temperature.
Prazo: H0, up to 60 minutes after inclusion
|
Evaluate the relationship between body temperature and expiratory temperature |
H0, up to 60 minutes after inclusion
|
Medidas de resultados secundários
Medida de resultado |
Prazo |
|---|---|
|
Estimar a humidade absoluta expiratória com base na temperatura medida
Prazo: H0, até 60 minutos após a inclusão
|
H0, até 60 minutos após a inclusão
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- 2026-4543
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .