Functional Outcomes and Control Using Synchron BCI - Canada (FOCUS-CAN):
The Synchron BCI motor neuroprosthesis is an implanted brain-computer interface indicated for adults with bilateral upper-limb motor impairment, including Motor Neuron Disease. The Synchron BCI is intended to replace the function of motor neurons by detecting, translating and transmitting motor-related brain signals to restore clinically meaningful control of digital devices.
The Synchron BCI is an implanted BCI device that interfaces with the brain to enable control of digital devices in individuals with bilateral upper-limb motor impairment. The Synchron BCI is designed to record volitional motor-related neural signals from the sensorimotor cortices and translate these signals into digital motor outputs to enable control of digital devices to improve functional independence. The system includes both implantable and non-implantable components. Implantable components are the Stentrode and the Transceiver.
Tipo de estudo
Inscrição (Real)
Estágio
- Não aplicável
Contactos e Locais
Locais de estudo
-
-
-
Toronto, Canadá, M5C 1R6
- St. Michael's Hospital
-
-
Ontario
-
Toronto, Ontario, Canadá, M5C 1N2
- Sunnybrook Health Sciences Centre
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
INCLUSION CRITERIA:
- Able to provide informed consent to participate in the study, in the opinion of the Investigator(s).
- Diagnosis of amyotrophic lateral sclerosis or motor neuron disease, with bilateral upper-limb paresis.
- Aged 18 years or older.
- Life expectancy greater than 12 months post-implantation, in the opinion of the Investigator(s).
- Preserved precentral gyrus assessed using CT.
- Suitable vascular anatomy, in the opinion of the Investigator(s), assessed using CT venography.
- Suitable anatomy for subcutaneous pocket creation.
- Able to undergo anesthesia.
- Willing and able to comply with investigational requirements, including clinical testing visits and training visits in the home.
- Caregiver(s) willing and able to facilitate study visits, including visits at the study site and in the home, and BCI use outside of study visits (e.g., device charging).
- Patient and Caregiver fluent in English.
- Suitable home environment for BCI training, including an internet connection.
EXCLUSION CRITERIA:
- Unrealistic expectations regarding the potential benefits of the device, in the opinion of the Investigator(s).
- Active infection or unexplained fever in the 48 hours prior to informed consent.
- Major psychiatric disorder that may adversely impact the participant's safety or study compliance (e.g., severe depression, psychotic features, personality disorder, severe emotional lability, substance abuse), in the opinion of the Investigator(s).
- Dementia or cognitive dysfunction that would impact the participant's ability to participate in study activities, in the opinion of the Investigator(s).
- Active implanted device (e.g., deep brain stimulator, cardiac defibrillator, pacemaker, vagal nerve stimulator, spinal cord stimulator, diaphragmatic pacer, etc.).
- Known allergy to patient-contacting materials included in the implanted device (listed in Physician Implant Manual).
- Contraindication to angiographic imaging or iodine contrast media.
- History of central venous sinus thrombosis.
- Recent history of new venous thromboembolic event (in the 6 months prior to implant) or recurrent history of venous thromboembolic disease.
- Contraindication to antithrombotic therapy, in the opinion of the Investigator(s).
- Participant is at substantially increased risk of infection, including immunocompromised status, recurrent or chronic infection, or poorly controlled diabetes mellitus.
- Significant risk of non-healing of the subcutaneous pocket incision, including history of chronic non-healing surgical wounds or poorly controlled diabetes mellitus.
- Currently receiving or expected to require medical treatment that may be precluded by device implant, including magnetic resonance imaging, transcranial magnetic stimulation, electroconvulsive therapy, transcranial ultrasound, shortwave, microwave, and/or therapeutic ultrasound diathermy, or balloon angioplasty or stenting in the target vessel.
- Pregnant or breast feeding.
- Patients who are currently enrolled in any other clinical trial that would confound interpretation of safety or effectiveness data or may interfere with the ability to meet study requirements.
- Patients with ALS due to SOD1 mutations on gene therapy.
- Any other disease or disorder that could significantly affect participation in the study, in the opinion of the Investigator(s). Examples may include corrected vision insufficient for viewing computer screens or hearing insufficient for following verbal instructions, which might impact the participant's ability to participate in BCI training and testing.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Outro
- Alocação: N / D
- Modelo Intervencional: Atribuição de grupo único
- Mascaramento: Nenhum (rótulo aberto)
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Outro: Single
Single Arm |
The Stentrode is an endovascular electrode array that senses electrical signals from the sensorimotor cortices. |
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Prazo |
|---|---|
|
Eventos adversos graves relacionados com o dispositivo que resultem em morte ou incapacidade permanentemente aumentada até 90 dias após o implante.
Prazo: 3 Meses
|
3 Meses
|
Medidas de resultados secundários
Medida de resultado |
Prazo |
|---|---|
|
Eventos adversos graves relacionados com o dispositivo que resultam em morte ou incapacidade permanentemente aumentada até 1 ano após o implante.
Prazo: 12 Meses
|
12 Meses
|
|
Patência do vaso alvo avaliada por venografia por TC aos 90 e 365 dias após o implante.
Prazo: 3 Meses e 12 Meses
|
3 Meses e 12 Meses
|
|
Migração do dispositivo avaliada através de venografia por TC aos 90 e 365 dias após o implante.
Prazo: 3 Meses e 12 Meses
|
3 Meses e 12 Meses
|
Outras medidas de resultado
Medida de resultado |
Prazo |
|---|---|
|
Tempo em dias desde a implantação até à ativação do dispositivo.
Prazo: Número de dias desde o implante do dispositivo até à ativação do dispositivo, até 12 meses após o implante.
|
Número de dias desde o implante do dispositivo até à ativação do dispositivo, até 12 meses após o implante.
|
|
Estabilidade do sinal BCI registado, utilizando medições mensais até 1 ano após a implantação do dispositivo.
Prazo: 12 Meses
|
12 Meses
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- S-03-01
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
produto fabricado e exportado dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .