Comparison of 26G and 30G Needles for Masseter Trigger Point Injections in Patients With Myofascial Pain Syndrome (MASS-NEEDLE)
Comparison of Two Needle Gauges (26G and 30G) for Masseter Muscle Trigger Point Injection in Myofascial Pain Syndrome: A Randomized Split-Face Controlled Trial
This randomized split-face study aims to compare the effects of 26G and 30G needles used for masseter trigger point injections with lidocaine in patients with myofascial pain syndrome. Both needle sizes are routinely used in clinical practice. Pain reduction from baseline to day 14 will be compared between the two sides of the face. Secondary outcomes include pain reduction at day 7, procedural pain, injection-site tenderness at 48 hours, bruising, and patient preference. The split-face design allows both needle sizes to be evaluated in the same patient, minimizing individual differences.
Обзор исследования
Статус
Статус
Условия
Условия
Вмешательство/лечение
Вмешательство/лечение
Подробное описание
Both 26G and 30G needles were routinely used for masseter trigger point injection in our clinic. Comparing these gauges under otherwise standardized conditions may help clarify whether needle selection affects short-term pain reduction, procedural pain, and patient preference. A randomized split-face design permits this comparison within the same patient, reducing the influence of differences between individuals.
The primary objective of this study was to compare the within-patient reduction in palpation-evoked masseter pain between sides treated with 26G and 30G needles from baseline to day 14 following lidocaine injection. Secondary objectives were to compare pain reduction at day 7, overall procedural pain, injection-site tenderness at 48 hours, ecchymosis, and patient preference.
Тип исследования
Тип исследования
Регистрация (Оцененный)
Регистрация
Фаза
Фаза
- Непригодный
Контакты и местонахождение
Контакты исследования
Контакты исследования
- Имя: Ceylan Güzel, Dr
- Номер телефона: +90 5364501650
- Электронная почта: ceylan.guzel@medipol.edu.tr
Места учебы
-
-
-
Istanbul, Турция (Туркие), 34214
- Medipol Mega University Hospital
-
Контакт:
- Ceylan Güzel, Dr.
- Номер телефона: +905364501650
- Электронная почта: ceylan.guzel@medipol.edu.tr
-
-
Критерии участия
Критерии приемлемости
Критерии приемлемости
Возраст, подходящий для обучения
Принимает здоровых добровольцев
Полы, имеющие право на обучение
Описание
Inclusion Criteria:
Adults aged 18-65 years.
Bilateral masseter myofascial pain persisting for at least 8 weeks.
Baseline palpation-evoked pain score of ≥6 on an 11-point Numerical Rating Scale (NRS) on each side.
Presence of at least one active myofascial trigger point within a palpable taut band in each masseter muscle, reproducing the patient's familiar pain.
Diagnosis established according to the Diagnostic Criteria for Temporomandibular Disorders (DC/TMD).
No previous treatment for masseter myofascial pain.
Exclusion Criteria:
- Concomitant temporomandibular joint arthralgia.
Known allergy to local anesthetics.
Pregnancy or lactation.
Active infection, open lesion, or malignancy at the injection site.
Bleeding diathesis or use of anticoagulant or antiplatelet medications.
Inability to cooperate with study procedures.
Учебный план
Как устроено исследование?
Детали дизайна
- Основная цель: Уход
- Распределение: Рандомизированный
- Интервенционная модель: Одногрупповое задание
- Маскировка: Двойной
Количество рук
Оружие и интервенции
Группа участников / АрмияГруппа участников / Армия |
Вмешательство/лечениеВмешательство/лечение |
|---|---|
|
Экспериментальный: Bilateral Masseter Trigger Point Injection 26 G
All participants received bilateral masseter trigger point injections in a single session. A 26-gauge (26G) needle was randomly assigned to one masseter muscle and a 30-gauge (30G) needle to the contralateral masseter muscle using a computer-generated randomization sequence. Each masseter received 0.3 mL of 2% lidocaine without vasoconstrictor using a standardized injection technique. The right masseter was injected first in all participants. Participants and the outcome assessor were blinded to needle-gauge allocation, whereas the injecting clinician was not blinded. |
A 26-gauge (0.45 × 13 mm) needle was used for masseter trigger point injection. A total of 0.3 mL of 2% lidocaine without vasoconstrictor was administered using a standardized injection technique. |
|
Экспериментальный: Bilateral Masseter Trigger Point Injection 30 G
All participants received bilateral masseter trigger point injections in a single session. A 26-gauge (26G) needle was randomly assigned to one masseter muscle and a 30-gauge (30G) needle to the contralateral masseter muscle using a computer-generated randomization sequence. Each masseter received 0.3 mL of 2% lidocaine without vasoconstrictor using a standardized injection technique. The right masseter was injected first in all participants. Participants and the outcome assessor were blinded to needle-gauge allocation, whereas the injecting clinician was not blinded. |
A 30-gauge (0.45 × 13 mm) needle was used for masseter trigger point injection. A total of 0.3 mL of 2% lidocaine without vasoconstrictor was administered using a standardized injection technique. |
Что измеряет исследование?
Первичные показатели результатов
Первичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Between-Needle Difference in Palpation-Evoked Masseter Pain Reduction From Baseline to Day 14
Временное ограничение: Baseline and Day 14 (14 days after injection)
|
Palpation-evoked masseter pain was assessed separately on each side using an 11-point Numerical Rating Scale (NRS), ranging from 0 (no pain) to 10 (worst possible pain). At baseline and day 14, pain was recorded at the most painful trigger point identified during each assessment. Pain reduction was calculated as baseline NRS minus day 14 NRS for each side. The primary outcome was the within-participant difference in pain reduction between the 30G and 26G needle interventions (30G minus 26G). Positive values indicated greater pain reduction with 30G. |
Baseline and Day 14 (14 days after injection)
|
Вторичные показатели результатов
Вторичные показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Between-Needle Difference in Palpation-Evoked Masseter Pain Reduction at Day 7
Временное ограничение: Baseline and Day 7
|
Palpation-evoked masseter pain was assessed separately on each side using an 11-point Numerical Rating Scale (NRS), ranging from 0 (no pain) to 10 (worst possible pain). Pain reduction was calculated as baseline NRS minus day 7 NRS for each side. The within-participant difference in pain reduction between the 30G and 26G needle interventions was calculated as 30G minus 26G. Positive values indicated greater pain reduction with 30G. |
Baseline and Day 7
|
Другие показатели результатов
Другие показатели результатов
Мера результата |
Мера Описание |
Временное ограничение |
|---|---|---|
|
Overall Procedural Pain During Masseter Trigger Point Injection
Временное ограничение: Day 0 (within 60 seconds after each injection)
|
Overall procedural pain was assessed separately for the 26G and 30G needle interventions using an 11-point Numerical Rating Scale (NRS), ranging from 0 (no pain) to 10 (worst possible pain). Participants rated the entire injection procedure, including skin penetration, intramuscular needle manipulation, and lidocaine administration. Pain was recorded within 60 seconds after each injection. Within-participant pain scores were compared between needle gauges. |
Day 0 (within 60 seconds after each injection)
|
Соавторы и исследователи
Спонсор
Спонсор
Даты записи исследования
Изучение основных дат
Начало исследования (Оцененный)
Начало исследования
Первичное завершение (Оцененный)
Первичное завершение
Завершение исследования (Оцененный)
Завершение исследования
Даты регистрации исследования
Первый отправленный
Первый отправленный
Впервые представлено, что соответствует критериям контроля качества
Впервые представлено, что соответствует критериям контроля качества
Первый опубликованный (Действительный)
Первый опубликованный
Обновления учебных записей
Последнее опубликованное обновление (Действительный)
Последнее опубликованное обновление
Последнее отправленное обновление, отвечающее критериям контроля качества
Последнее отправленное обновление, отвечающее критериям контроля качества
Последняя проверка
Последняя проверка
Дополнительная информация
Термины, связанные с этим исследованием
Ключевые слова
Дополнительные соответствующие термины MeSH
Другие идентификационные номера исследования
Другие идентификационные номера исследования
- E-10840098-50.04-5377
Информация о лекарствах и устройствах, исследовательские документы
Изучает лекарственный продукт, регулируемый FDA США.
Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.
продукт, произведенный в США и экспортированный из США.
Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .