Diagnostisk validering av bärbart EKG-övervakningsplåster, ATP-C120
Diagnostisk validering av bärbar kontinuerlig EKG-övervakningsplåster, ATP-C120, hos högriskpatienter för nyuppstått förmaksflimmer
A new wearable patch-type device, ATP-C120 (ATsens, Seongnam, Korea) is a novel, single-lead ECG monitoring device and can continuously monitor the ECG signal for upto 11 days. This study is designed to experiment its diagnostic capability of new-onset atrial fibrillation in high risk patients. Several studies reported that validated CHA2DS2-VASc score has high performance in predicting new-onset atrial fibrillation and there are over 10 percent of new-onset atrial fibrillation in patients whose calculated CHA2DS2-VASc scores are ≥ 2. Thus, through this study, the investigators sought to evaluate the validation of early detection of new-onset atrial fibrillation by ATP-C120.
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
The prevention of stroke associated with atrial fibrillation is a leading global health concern. This devastating event is largely preventable with anticoagulant therapy. Therefore, the early detection and accurate diagnosis of arrhythmia are crucial for prevention of adverse outcome. However, because atrial fibrillation is often intermittent and mostly asymptomatic, it is difficult to capture an excise event.
Conventional electrocardiogram (ECG) monitoring devices including multi-lead portable ECG monitoring device, event-detection monitoring device, and implantable ECG monitoring device are useful for early detection of atrial fibrillation, but these devices have various drawbacks such as requirement of multiple out-patient visits and need of invasive implantation of devices.
A new wearable patch-type device, ATP-C120 (ATsens, Seongnam, Korea) is a novel, single-lead ECG monitoring device and can continuously monitor the ECG signal for upto 11 days. It has recently demonstrated its diagnostic capability and safety compared to the conventional ECG monitoring systems . Yet, it has not widely used in real-world. So, this study is designed to experiment its diagnostic capability of new-onset atrial fibrillation in high risk patients. Several studies reported that validated CHA2DS2-VASc score has high performance in predicting new-onset atrial fibrillation and there are over 10 percent of new-onset atrial fibrillation in patients whose calculated CHA2DS2-VASc scores are ≥ 2. Thus, through this study, the investigators sought to evaluate the validation of early detection of new-onset atrial fibrillation by ATP-C120.
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
-
Daegu, Sydkorea
- Kyungpook National University Hospital
-
-
Gyeonggi-do
-
Seongnam-si, Gyeonggi-do, Sydkorea, 463-707
- Seoul National Universtiy Bundang Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- patients who provide written and informed consent to participate
- patients whose calculated CHA2DS2-VASc score is ≥ 2
Exclusion Criteria:
- subjects previously diagnosed with atrial fibrillation
- subjects implanted pacemaker, cardioverter-defibrillator, or any electrical devices
- subjects had skin problems such as allergic contact dermatitis
- female patients who are pregnant, or lactating status.
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Diagnostisk
- Tilldelning: N/A
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: ATP-C120 application
ATP-C120 will be applied to the high patients for new-onset atrial fibrillation |
ATP-C120 is a novel, single-lead ECG monitoring device which can continuously monitor the ECG signal as long as 14 days (11 days if the device is connected to the smartphone via Bluetooth) when attached to skin adjacent to the heart of patients. It weighs about 8.3 g, with a size of 84 × 39 × 8.3 mm. When the device is attached to the patient, several predefined methods were utilized to prevent the occurrence of noise or signal loss. First, the skin was cleansed and disinfected using a 70% ethanol solution. Skin hair was removed if needed. Then the protection film was removed from the patient-side surface of the device. The device is placed at the left 3rd intercostal space 45 degrees tilted toward the inside. |
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Rate of new-onset atrial fibrillation
Tidsram: 11 days
|
new-onset atrial fibrillation recognized by ATP-C120 patch device |
11 days
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Rate of new-onset atrial fibrillation
Tidsram: 6 month
|
new-onset atrial fibrillation recognized by conventional ECG monitoring device |
6 month
|
Samarbetspartners och utredare
Samarbetspartners
Utredare
- Huvudutredare: Chang-Hwan Yoon, MD.,Ph.D., Seoul National University Bundang Hospital
Publikationer och användbara länkar
Allmänna publikationer
- Go AS, Hylek EM, Phillips KA, Chang Y, Henault LE, Selby JV, Singer DE. Prevalence of diagnosed atrial fibrillation in adults: national implications for rhythm management and stroke prevention: the AnTicoagulation and Risk Factors in Atrial Fibrillation (ATRIA) Study. JAMA. 2001 May 9;285(18):2370-5. doi: 10.1001/jama.285.18.2370.
- Choi W, Kim SH, Lee W, Kang SH, Yoon CH, Youn TJ, Chae IH. Comparison of Continuous ECG Monitoring by Wearable Patch Device and Conventional Telemonitoring Device. J Korean Med Sci. 2020 Nov 16;35(44):e363. doi: 10.3346/jkms.2020.35.e363.
- Gladstone DJ, Spring M, Dorian P, Panzov V, Thorpe KE, Hall J, Vaid H, O'Donnell M, Laupacis A, Cote R, Sharma M, Blakely JA, Shuaib A, Hachinski V, Coutts SB, Sahlas DJ, Teal P, Yip S, Spence JD, Buck B, Verreault S, Casaubon LK, Penn A, Selchen D, Jin A, Howse D, Mehdiratta M, Boyle K, Aviv R, Kapral MK, Mamdani M; EMBRACE Investigators and Coordinators. Atrial fibrillation in patients with cryptogenic stroke. N Engl J Med. 2014 Jun 26;370(26):2467-77. doi: 10.1056/NEJMoa1311376.
- Hart RG, Pearce LA, Aguilar MI. Meta-analysis: antithrombotic therapy to prevent stroke in patients who have nonvalvular atrial fibrillation. Ann Intern Med. 2007 Jun 19;146(12):857-67. doi: 10.7326/0003-4819-146-12-200706190-00007.
- Potpara TS, Lane DA, Lip GY. Optimizing stroke prevention in atrial fibrillation: better adherence and compliance from patients and physicians leads to better outcomes. Europace. 2015 Apr;17(4):507-8. doi: 10.1093/europace/euv041. No abstract available.
- Waks JW, Buxton AE. Risk Stratification for Sudden Cardiac Death After Myocardial Infarction. Annu Rev Med. 2018 Jan 29;69:147-164. doi: 10.1146/annurev-med-041316-090046.
- Camm AJ, Corbucci G, Padeletti L. Usefulness of continuous electrocardiographic monitoring for atrial fibrillation. Am J Cardiol. 2012 Jul 15;110(2):270-6. doi: 10.1016/j.amjcard.2012.03.021. Epub 2012 Apr 12.
- Healey JS, Connolly SJ, Gold MR, Israel CW, Van Gelder IC, Capucci A, Lau CP, Fain E, Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH; ASSERT Investigators. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med. 2012 Jan 12;366(2):120-9. doi: 10.1056/NEJMoa1105575.
- Kwun JS, Lee JH, Park BE, Park JS, Kim HJ, Kim SH, Jeon KH, Cho HW, Kang SH, Lee W, Youn TJ, Chae IH, Yoon CH. Diagnostic Value of a Wearable Continuous Electrocardiogram Monitoring Device (AT-Patch) for New-Onset Atrial Fibrillation in High-Risk Patients: Prospective Cohort Study. J Med Internet Res. 2023 Sep 18;25:e45760. doi: 10.2196/45760.
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- B-2009/634-003
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .