此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Blood Propofol Concentrations in Children During Spinal Surgery

Comparison of Measured Versus Predicted Blood Propofol Concentrations During Total Intravenous Anaesthesia in Children Undergoing Spinal Surgery

During major spinal surgery evoked potential monitoring is performed to detect spinal cord damage. Intra-venous anaesthesia is the preferred anaesthetic technique because volatile anaesthetic agents supress the evoked potentials. Total Intra-Venous Anaesthesia (TIVA) with propofol is commonly administered as a Target Controlled Infusion (TCI). The TCI is an automated drug delivery system which administers propofol to achieve a desired blood concentration, based on an in built pharmaco-kinetic data (TCI model) derived from previous studies. The TCI model also provides a real time predicted blood concentration to facilitate the anaesthetist to adjust the target concentration of propofol.

The TCI algorithm is based on pharmaco-kinetic data derived from previous studies in a relatively small number of patients, by a "best fit" relationship between blood levels, infusion rates and other factors (such as age and weight). Several factors make it possible for a wide discrepancy between the predicted and the true blood concentrations. This difference can be higher in children compared to adults. Also blood loss and administration of large volumes of intravenous fluids can affect the blood concentrations. This study aims to identify the difference between the predicted and true blood concentrations by using Pelorus 1500, a bedside blood propofol measurement device, in children undergoing major spinal surgery under TIVA.

研究概览

研究类型

介入性

注册 (实际的)

20

阶段

  • 第四阶段

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • London、英国、WC1N 3JH
        • Great Ormond Street Hospital for Children NHS Trust

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

5年 至 18年 (孩子、成人)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Children undergoing major spinal surgery under propofol TCI
  • Surgery expecting to last more than 3 hours.

Exclusion Criteria:

  • Major hepatic or renal disease

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
实验性的:Single arm
The intervention in this study involves taking blood sample from an existing arterial line for measurement of blood propofol levels. The drug in evaluation is Propofol 2% (Diprivan 2%, Astra Zeneca UK) administered as a target controlled infusion using the commercially available paediatric TCI models (Paedfusor and Marsh models). The dose range is usually between a target concentration of 3-8 mcg/ml. However the anaesthetic management is not changed for the study. The blood concentrations of propofol will be measured using Pelorus 1500 (Sphere Medical, UK), a CE marked device. The anaesthetist will be blinded from the measurements, unless the measured value was outside the safe limit ( < 3 mcg/ml or > 10mcg/ml).
a bedside blood propofol measurement device
其他名称:
  • Sphere Medical, UK

研究衡量的是什么?

主要结果指标

结果测量
大体时间
The absolute difference between the measured and predicted concentrations of propofol in micrograms per ml of blood.
大体时间:Up to 5 hours during the maintenance phase of anaesthesia, to allow a maximum of 10 samples at 20 to 30 min intervals.
Up to 5 hours during the maintenance phase of anaesthesia, to allow a maximum of 10 samples at 20 to 30 min intervals.

次要结果测量

结果测量
措施说明
大体时间
Median Performance Error (MDPE)
大体时间:Up to 5 hours during the maintenance phase of anaesthesia, to allow a maximum of 10 samples at 20 to 30 min intervals.
The median value of ratio between the measured and predicted concentration of propofol to the predicted concentration (Performance error) in blood. Expressed as a percentage. This is a measure of overall bias of the target controlled infusion.
Up to 5 hours during the maintenance phase of anaesthesia, to allow a maximum of 10 samples at 20 to 30 min intervals.
Median Absolute Performance Error (MDAPE)
大体时间:Up to 5 hours during the maintenance phase of anaesthesia
The median value of the ratio of the absolute difference (excluding the sign) between the measured and predicted concentrations to the predicted concentration (Absolute performance error) in blood. Expressed as percentage. This is a measure of the accuracy of the target controlled infusion.
Up to 5 hours during the maintenance phase of anaesthesia
Wobble
大体时间:Up to 5 hours during the maintenance phase of anaesthesia
The median value of the difference between the individual performance errors and the Median Performance Error (MDPE). This is a measure of the distribution of the performance errors around the median.
Up to 5 hours during the maintenance phase of anaesthesia
Divergence
大体时间:Up to 5 hours during the maintenance phase of anaesthesia
The median of the regression coefficient of the performance error against time. This is a measure of how the target controlled infusion performs with time.
Up to 5 hours during the maintenance phase of anaesthesia

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Michael RJ Sury, FRCA PhD、Great Ormond Street Hospital For Children NHS Foundation Trust
  • 首席研究员:Selvakumar Panchatsharam, MBBS FRCA、Great Ormond Street Hospital For Children NHS Foundation Trust

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2013年1月1日

初级完成 (实际的)

2013年7月1日

研究完成 (实际的)

2013年7月1日

研究注册日期

首次提交

2013年8月13日

首先提交符合 QC 标准的

2013年8月29日

首次发布 (估计)

2013年8月30日

研究记录更新

最后更新发布 (估计)

2013年8月30日

上次提交的符合 QC 标准的更新

2013年8月29日

最后验证

2013年8月1日

更多信息

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

Pelorus 1500的临床试验

3
订阅