此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

钆匹烯醇评估成人先天性心脏解剖结构和血流动力学的比较效果

2026年10月30日 更新者:Albert Hsiao、University of California, San Diego

The goal of this clinical trial is to learn how well and at what doses gadopiclenol, a new intravenous (IV) contrast agent used for MRI, works to produce high-quality MRI images of the heart, in patients with a history of congenital heart disease, when compared to gadobenate dimeglumine, the IV contrast agent that is normally used at our institution for heart (cardiac) MRI. The main questions it aims to answer are:

  • Does using gadopiclenol result in similar or superior image quality, similar signal-to-noise ratio (SNR), and similar flow measurements with 4-dimensional (4D) flow cardiac MRI when compared to gadobenate dimeglumine?
  • At what dose(s) does gadopiclenol result in similar image quality (using the above metrics) for cardiac MRI when compared to gadobenate dimeglumine?

Researchers will compare cardiac MRI images obtained after administration of gadopiclenol to cardiac MRI images obtained after administration of gadobenate dimeglumine (called the standard of care treatment) to see if the images are of similar or superior quality.

Participants will:

  • Be randomized to receive either gadopiclenol at one of three different doses or gadobenate dimeglumine before their congenital heart cardiac MRI
  • Undergo their congenital heart cardiac MRI as they would during the course of normal clinical care.

研究概览

详细说明

At the University of California San Diego (UCSD), the investigators have developed a premier advanced clinical cardiovascular imaging program, which is a critical component of our Adult Congenital Heart Association (ACHA)-accredited adult congenital heart program. Central to these programs is 4D Flow MRI, which enables hemodynamic assessment of patients with repaired and unrepaired congenital heart disease. Adults with congenital heart disease require routine MRI for surveillance and management of complications of disease and repairs, and 4D Flow allows us to reliably perform these exams efficiently and accurately. Multiple works by our group, and confirmed by others, have highlighted the value of 4D Flow MRI for evaluating this patient population, and for vascular imaging applications beyond the heart.

Gadopiclenol is a recently FDA-approved intravenous, extracellular gadolinium contrast agent indicated for use in MRI. Though it has been shown to be effective in detection of central nervous system (CNS) lesions and of lesions outside the CNS, its performance in cardiovascular imaging is unknown, particularly in cardiac MRI performed for evaluation of adult congenital heart disease. The investigators therefore seek to evaluate whether use of gadopiclenol results in superior image quality compared to, and therefore may be used in place of, gadobenate dimeglumine, our current standard of care in 4D Flow MRI and MR Angiography (MRA).

In our current clinical practice, like many others, gadobenate dimeglumine at 0.3 mL/kg (0.15 mmol/kg) is our standard of care for vascular enhancement and cardiac MRI, favored due to its long blood pool residence time, which parallels the longer acquisition time for 4D Flow MRI (~10 minutes), and its strong T1 shortening properties. Gadopiclenol, with its stronger T1 shortening properties and similar pharmacokinetics, may achieve similar effects but as a macrocyclic agent is a more stable gadolinium agent, and theoretically may have a better retention profile than older linear agents due to its lower approved dose. The investigators therefore seek to determine whether gadopiclenol may be used in place of gadobenate dimeglumine for contrast-enhanced 4D Flow MRI and MRA. Since the optimal dose of gadopiclenol for this purpose is unknown, the investigators will assess the relative performance of gadopiclenol across a dose range.

Standard dosing for gadopiclenol for CNS and abdominal imaging in adult and pediatric patients is 0.05 mmol/kg actual body weight (equivalent to 0.1 mL/kg). However, its safety has been evaluated at doses ranging from 0.025 mmol/kg to 0.3 mmol/kg. The investigators therefore plan to assess the signal to noise ratio and image quality of patients undergoing cardiac MRI using gadopiclenol at three doses (0.075 mmol/kg, 0.10 mmol/kg, 0.15 mmol/kg) against our standard of care (gadobenate dimeglumine at 0.3 mL/kg (0.15 mmol/kg)). The investigators hypothesize that gadopiclenol at each dose will be non-inferior to gadobenate dimeglumine, achieving similar qualitative image quality, similar SNR, and similar standard deviation amongst flow measurements with 4D Flow MRI. There is a strong possibility that gadopiclenol at an equimolar gadolinium dose to gadobenate dimeglumine will provide superior qualitative image quality and superior SNR in contrast-enhanced MRA and reduce standard deviation amongst flow measurements with 4D Flow MRI.

研究类型

介入性

注册 (实际的)

161

阶段

  • 第三阶段

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • California
      • San Diego、California、美国、92037
        • University of California San Diego Health

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Adult patients (≥ 18 years old)
  • History of congenital heart disease and scheduled to undergo standard of care cardiac MRI and chest MRA as part of routine clinical care
  • English is patient's primary spoken language

Exclusion Criteria:

  • Pediatric patients
  • Pregnant patients
  • Patients with ongoing acute kidney injury (AKI) or severe, chronic kidney disease (GFR < 30 mL/min/1.73m2)
  • History of hypersensitivity reaction to gadolinium based contrast agent
  • English is not the patient's primary spoken language

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:其他
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:三倍

武器和干预

参与者组/臂
干预/治疗
有源比较器:钆贝酸二葡胺 0.15 mmol/kg(护理标准)

Gadobenate dimeglumine is an FDA-approved GBCA that is used in standard clinical practice at UCSD for contrast-enhanced MRI/MRA studies, including cardiac MRI/MRA. This contrast agent is the standard of care to which gadopiclenol will be compared.

其他名称:
  • 多钩
实验性的:钆匹烯醇 0.075 mmol/kg

Gadopiclenol is an FDA-approved gadolinium-based contrast agent (GBCA) for neurological and abdominal contrast-enhanced MRI. Participants will receive this contrast agent at one of three different doses prior to undergoing a congenital heart cardiac MRI/MRA. This contrast agent will be compared to gadobenate dimeglumine, the standard-of-care.

其他名称:
  • 维威
实验性的:钆匹烯醇 0.10 mmol/kg

Gadopiclenol is an FDA-approved gadolinium-based contrast agent (GBCA) for neurological and abdominal contrast-enhanced MRI. Participants will receive this contrast agent at one of three different doses prior to undergoing a congenital heart cardiac MRI/MRA. This contrast agent will be compared to gadobenate dimeglumine, the standard-of-care.

其他名称:
  • 维威
实验性的:钆匹烯醇 0.15 mmol/kg

Gadopiclenol is an FDA-approved gadolinium-based contrast agent (GBCA) for neurological and abdominal contrast-enhanced MRI. Participants will receive this contrast agent at one of three different doses prior to undergoing a congenital heart cardiac MRI/MRA. This contrast agent will be compared to gadobenate dimeglumine, the standard-of-care.

其他名称:
  • 维威

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Image Quality
大体时间:Image Quality will be assessed on a rolling basis during the study by all radiologists and will be completed within one month of the conclusion of enrollment.

Images will be qualitatively scored by three attending radiologists for quality of contrast enhancement on a 5-point likert Scale

Image Quality will be assessed on a rolling basis during the study by all radiologists and will be completed within one month of the conclusion of enrollment.
Signal-to-Noise Ratio (SNR)
大体时间:SNR will be assessed on a rolling basis during the study by the study team and will be completed within one month of the conclusion of enrollment.

Signal-to-noise will be measured from the blood pool in the aorta and main pulmonary artery and compared against myocardial signal for contrast-to-background calculations in contrast-enhanced MRA and 4D Flow signal images. This ca be readily performed by placing a region of interest (ROI) within the vessel of interest and calculating the standard deviation of signal intensities relative to mean signal intensity.

SNR will be assessed on a rolling basis during the study by the study team and will be completed within one month of the conclusion of enrollment.
Standard Deviation of Volumetric Flow Measurements
大体时间:Standard deviation of flow measurements will be assessed on a rolling basis during the study by all attending radiologists and will be completed within one month after the conclusion of enrollment.

We will measure standard deviation of volumetric flow measurements from the aorta and main pulmonary artery from ROIs that are typically used in our clinical routine to measure systemic and pulmonary blood flow. The standard error in these measurements will be compared between each of the four randomized conditions.

Standard deviation of flow measurements will be assessed on a rolling basis during the study by all attending radiologists and will be completed within one month after the conclusion of enrollment.

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Albert Hsiao, MD/PhD、Department of Radiology, UC San Diego

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2024年8月5日

初级完成 (实际的)

2026年4月23日

研究完成 (实际的)

2026年8月23日

研究注册日期

首次提交

2024年5月6日

首先提交符合 QC 标准的

2024年5月6日

首次发布 (实际的)

2024年5月9日

研究记录更新

最后更新发布 (实际的)

2026年11月3日

上次提交的符合 QC 标准的更新

2026年10月30日

最后验证

2026年10月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

是的

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅