Accuro 3S 的准确性
Accuro 3S 的可行性与准确性
The main purpose of this study is to evaluate the feasibility and accuracy of the Accuro 3S to provide live guidance when performing a neuraxial technique (e.g., spinal, or epidural).
The Accuro 3S is a new device that was designed to allow for midline live neuraxial guidance. If the device can perform as the manufacturers claim the device will permit the performance of epidurals as close as doing them under fluoroscopy.
研究概览
详细说明
Feasibility will be assessed in terms of how easily the device can be used and if it poses any discomfort to the patient. Live guidance is defined as the ability to see and change, if needed, the needle trajectory as it is advanced. Accuracy is defined as a measurement of depth by device versus the actual depth of the needle, number of needle attempts (skin punctures) and number of needle redirection.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Antonio Gonzalez-Fiol, MD
- 电话号码:203-785-2802
- 邮箱:antonio.gonzalez-fiol@yale.edu
学习地点
-
-
Connecticut
-
New Haven、Connecticut、美国、06520
- Yale New Haven Hospital
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- The anesthetic plan for the patient includes a neuraxial anesthetic (spinal or epidural) as the main anesthetic for labor, surgery (e.g. orthopedic surgery, cesarean delivery) or for postoperative pain management (e.g, major abdominal surgery). *Given our labor and delivery volume (~300 epidurals/month) investigators think that they will only recruitc obstetric patients. In case of difficulty recruiting, then investigators will seek out a different patient population.
- No history of allergic reactions to adhesives used in standard epidural placements as per chart review or self-reported.
- Patient skin is intact in the area of placement of the epidural or spinal anesthesia.
- The patient is English speaking.
- For obstetric patients, the patient is admitted for cesarean delivery or for induction and is not in active labor. *Clarification - Patients scheduled for elective cesarean delivery will be approached for spinal anesthesia. Given that spinal anesthesia carries a smaller risk for post-dural puncture headache and other morbidities, investigators will recruit and perform 10 spinals on this patient population. Once comfortable with the technology, then will move to recruiting and performing epidurals. If during the spinal anesthesia trial the device does not provide accurate and clear needle visualization, the study will be culminated.
Exclusion Criteria:
- Contraindication to epidural catheter placement including bleeding diathesis (essential thrombocythemia, idiopathic thrombocytopenic purpura, von Willebrand disease, and hemophilia A or B), neurological dysfunction (multiple sclerosis, subacute myeloopticoneuropathy or preexisting lower limb neurological deficit), prior extensive spinal surgery or major spinal deformity, pre-operative use of anti-coagulant with planned use of therapeutic dose of anti-coagulant in post-operatively, documented pre-operative coagulopathy (INR greater than 1.3 not on Coumadin or PTT greater than 42), platelets less than 100, 000, or evidence of infection at potential epidural site.
- Presence of orthopedic implants in the spine.
- Skin dyscrasias or allergies to the ultrasound procedure.
- Unable to assume sitting position.
- Body Mass Index (BMI) less than 18.5 kg/m2.
学习计划
研究是如何设计的?
设计细节
- 主要用途:支持治疗
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Standard of Care and neuraxial guidance
Spinal or Epidural will be performed utilizing neuraxial guidance and standard of care techniques for placement. The spinal or epidural technique will not deviate from the standard of care. The device will only add the use of the disposable sterile drape and the use of the image will guide change of needle trajectory (without the need for contrast or radiation exposure) but not changing the technique. |
Provides anatomical guidance during the placement of needles or catheters using real-time visualization. |
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Mean number of needle attempts
大体时间:At time of procedure, 1 day
|
Defined as the number of times the needle is inserted into patients back |
At time of procedure, 1 day
|
|
Mean number of needle redirections
大体时间:At time of procedure, 1 day
|
Defined as number of needle movements in a cephalad, caudal or lateral position. |
At time of procedure, 1 day
|
|
Accuracy of device
大体时间:At time of procedure, 1 day
|
The ultrasound device can be used to measure the distance from skin to epidural space, this will be recorded as the estimated distance to epidural space (EDES). Once the epidural space is accessed the needle will be marked and measured. This will represent the Distance to epidural space (DES). The difference between EDES and DES will provide the accuracy of the device. Mean distance in centimeters (cm). |
At time of procedure, 1 day
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Patient satisfaction
大体时间:20 minutes post procedure
|
Likert scale asking the patient "How satisfied are you with the procedure performed?" Very dissatisfied, dissatisfied, Satisfied, very satisfied, extremely satisfied. Total score range 1-5 with higher scores indicating more satisfaction. |
20 minutes post procedure
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息