The Analysis and Applications of Dynamic Impression Insole
The Effect of Dynamic Impression Insoles on Plantar Pressure and Pain in Persons With Metatarsal Pain
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Early Phase 1
Contacts and Locations
Study Locations
-
-
-
Taipei City, Taiwan
- Taipei VGH
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Adults with metatarsal pain
- Active in walking without any walking aids
Exclusion Criteria:
- People with flexible flat foot
- Any acute inflammation
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Non-Randomized
- Interventional Model: Factorial Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Dynamic impression insole
We sequentially padded P-cell, Ethylene Vinyl Acetate, and Multiform on the 9-mm thick plastazote under daily walking compression to make dynamic impression insole.
|
We sequentially padded (1)a 6.5-mm thick P-cell (21 Shore A hardness, Acor orthopedic Inc.
Cleveland, Ohio, USA), and (2)a piece of metatarsal pad and arch support made of Ethylene Vinyl Acetate (EVA) (40 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany) to the bottom of the impressed 9-mm thick plastazote (15 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany) with double-sided adhesive tape in the forefoot region and just proximal to the first, second, and third metatarsal head region.
We additionally padded a 2-mm thick Multiform (30 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany) on the top of the impressed insole with double-sided adhesive tape.
|
|
Experimental: Custom molded insole
The custom molded insole was made by sequentially padded Multiform, P-cell, EVA, and cork on the positive plaster cast impressed by an impression box while holding the subtalar joint at a neutral position.
|
The custom molded insole was made by sequentially padded Multiform (30 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany), P-cell (21 Shore A hardness, Acor orthopedic Inc.
Cleveland, Ohio, USA), Ethylene Vinyl Acetate (EVA)(40 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany), and cork (50 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany) on the positive plaster cast impressed by an impression box while holding the subtalar joint at a neutral position.
|
|
Experimental: 9-mm uncompressed Plastazote insole
We used 9-mm flat Plastazote as an insole
|
We used 9-mm flat Plastazote(15 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany) as an insole
|
|
Experimental: 7-mm Ethylene Vinyl Acetate (EVA)
We used 7-mm flat Ethylene Vinyl Acetate (EVA) as an insole
|
We used 7-mm flat Ethylene Vinyl Acetate (EVA) (40 Shore A hardness, Schein orthopadie service KG.
Remscheid, Germany) as an insole
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change from baseline in peak plantar pressure value with different insoles
Time Frame: 4 weeks
|
We measure peak pressure (in unit of kPa) under forefoot, midfoot, and rearfoot when using different kinds of insoles by Pedar-X mobile in-shoe system (Novel gmbh, Munich, Germany), and data were processed with the Novel-Win Multimask analysis software (Novel gmbh, Munich, Germany) after using dynamic impression insole for four weeks.
|
4 weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change from baseline in pain levels using Visual Analog Scales
Time Frame: 4 weeks
|
We measure pain levels when using different kinds of insoles by Visual Analog Scales after using dynamic impression insole for four weeks.
|
4 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Chang Bao-Chi, Taipei Veterans General Hospital, Taiwan
Publications and helpful links
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 97-11-12A
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.