Vascular Healing After Deployment of Titanium-nitride-oxide-coated OPTIMAX™ Stent and PROMUS-ELEMENT™ Everolimus-Eluting Stent (TIDES-OCT)
A Randomized Prospective Multicenter Trial to Compare Vascular Healing and Vasodilation at 2 Months After Deployment of TItanium-nitride-oxide-coated OPTIMAX™ Stent and PROMUS-ELEMENT™ Drug-Eluting Stent in Patients With Acute Coronary Syndromes by Means of Optical Coherence Tomography and Coronary Flow Reserve
The purpose of this study is to compare vascular healing of the stented segment after deployment of titanium-nitride-oxide coated cobalt-chromium Optimax™-stent stent and Promus-Element™ everolimus-eluting stent in patients with acute coronary syndromes requiring percutaneous coronary intervention.
- Comparison of OCT and CFR findings of titanium-nitride-oxide coated cobalt-chromium Optimax™-stent and Promus-Element™ everolimus-eluting stent at two months after the index procedure.
- Comparison of intravascular coronary flow reserve measurement to non-invasive transthoracic echocardiography-derived coronary flow reserve measurement.
- Comparison of epicardial vasodilation to coronary microcirculatory vasodilation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Phase 4
Contacts and Locations
Study Locations
-
-
-
Kokkola, Finland
- Kokkola Central Hospital
-
Kuopio, Finland
- Heart Center, Kuopio University Hospital
-
Pori, Finland, 28500
- Heart Center, Satakunta Central Hospital
-
Turku, Finland
- Heart Center, Turku University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age >18 and <80 years
- STEMI or NSTEMI (assumed by investigator to be type 1 myocardial infarction, according to universal definitions of MI; EHJ 2007; 28(20):2525-38); or unstable angina (clinical symptoms of chest pain, ecg suggestive of reversible ischemia)
- Patient is willing to comply with specified follow-up evaluations
- Patient or legally authorized representative has been informed of the nature of the study, agrees to its provisions and has been provided written informed consent, approved by the appropriate Medical Ethics committee or Institutional Review Board
- Single de novo or non-stented restenosis lesion
- Patients with two-vessel disease may have undergone successful treatment of the non-target vessel with approved devices up to and including the index procedure but must be prior to the index target vessel treatment
- Target lesion (maximum 20 mm length by visual estimation) to be covered by a single stent of maximum 23mm length
- Reference vessel diameter must be >2.5mm and <4.0mm by visual estimate.
- The vessel diameter should be measured after pre-dilation procedure and after intracoronary nitroglycerin if vasospasm is suspected
- Target lesion >50% and <100% stenosed by visual estimate
Exclusion Criteria:
- Pre-existing diagnosis of diabetes irrespective of its type
- Impaired renal function (serum creatinine >177micromol/l) or on dialysis
- Platelet count < 10 e5 cells/mm3
- Patient has a history of bleeding diathesis or coagulopathy or patients in whom antiplatelet and and/or anticoagulation therapy is contraindicated
- Patient has received organ transplant or is on a waiting list for any organ transplant
- Patient has a known hypersensitivity or contraindication to aspirin, heparin/bivalirudin, clopidogrel/prasugrel, stainless steel alloy, or contrast agent that cannot be adequately pre-medicated
- Patient presents with cardiogenic shock
- Any significant medical condition which in the Investigator's opinion may interfere with the patient's optimal participation in the study
- Currently participating in another intestigational drug or device study
- Unprotected left main disease
- Ostial target lesions
- Chronic total occlusion
- Calcified target lesions that cannot be adequately pre-dilated
- Target lesion has excessive tortuosity unsuitable for stent delivery and deployment
- Target lesion involving bifurcation with a side branch larger than 2.0mm in diameter
- A >30% stenosis proximal or distal to the target lesion that cannot be covered with the same stent
- Diffuse distal disease
- Prior stent in the target vessel
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: CoCr-BAS
Stenting using Optimax™ cobalt-chromium alloy platform with a titanium-nitride-oxide coating
|
|
|
Active Comparator: PtCr-EES
Stenting using PROMUS Element™ Plus durable polymer everolimus-eluting stent built on a platinum-chromium platform.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Percentage of uncovered struts
Time Frame: 2 months
|
2 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Coronary flow reserve
Time Frame: 2 months
|
2 months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimate)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- SA-006
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Acute Coronary Syndrome
-
NCT07474441CompletedCKD | Coronary Angiography (CAG) | ACS (Acute Coronary Syndrome)
-
NCT07626840Not yet recruitingAcute Coronary Syndrome (ACS) Undergoing Percutaneous Coronary Intervention (PCI)
-
NCT07390006Not yet recruitingCoronary Artery Disease | Acute Coronary Syndrome/ Myocardial Infarction
-
NCT07351643Not yet recruitingSGLT2 Inhibitors | ACS (Acute Coronary Syndrome)
-
NCT07422688Enrolling by invitationIschemic Heart Disease | Ischemic Coronary Artery Disease | ACS (Acute Coronary Syndrome)
-
NCT07252388Not yet recruitingAcute Coronary Syndromes | Chronic Coronary Syndromes
-
NCT03797651RecruitingCoronary Artery Disease, Acute Coronary Syndrome
-
NCT07592312Not yet recruitingMyocardial Ischemia | Percutaneous Coronary Intervention | Chronic Coronary Syndrome | Coronary Computed Tomography Angiography | Acute Coronary Syndromes (ACS) | Coronary Arteries Disease
-
NCT07486791RecruitingHF - Heart Failure | ACS (Acute Coronary Syndrome)
-
NCT07259252RecruitingAcute Coronary Syndromes (ACS)
Clinical Trials on Stenting using Optimax™
-
NCT02701881Unknown
-
NCT02166190TerminatedCholangiocarcinoma Non-resectable | Unresectable Pancreatic Cancer
-
NCT03511144WithdrawnRheumatoid Arthritis | Osteoarthritis, Knee | Post-Traumatic Osteoarthritis of Knee | Varus Deformity, Not Elsewhere Classified, Knee | Valgus Deformity, Not Elsewhere Classified, Knee | Flexion Deformity, Knee | Fracture of Distal End of Femur | Fracture of Upper End of Tibia
-
NCT01444378CompletedPeripheral Vascular Disease | Peripheral Artery Disease
-
NCT03161327CompletedSmoking | Hypertension | Diabetes | Amputation | Hypercholesterolemia | Peripheral Artery Disease
-
NCT02165670WithdrawnStable Angina Pectoris | Unstable Angina Pectoris | Myocardial Infacrtion
-
NCT07541092Recruiting
-
NCT07428356RecruitingLiver Malignant Tumors