Failed Epidural Anesthesia During Labor: Evaluation of Risk Factors and Outcome

July 31, 2017 updated by: Ahmed Maged, Cairo University

Failed Epidural Anesthesia During Labor: Evaluation of Risk Factors and Impact on Labor ,Maternal and Fetal Outcomes

Women requesting epidural analgesia will receive a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices (Portex, Smith Medical, Hythe, UK) were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters will be inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% iss initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is established and maintained throughout labor and delivery using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals, continued at the same bolus dose until delivery.

Pain was evaluated using a 0-10 cm visual analogue scale (VAS) before, 15 and 30 min after the loading dose followed by hourly assessment until delivery. VAS score assessment was based specifically on abdominal or back pain resulting from contractions

Study Overview

Status

Unknown

Conditions

Intervention / Treatment

Detailed Description

Women requesting epidural analgesia will receive a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices (Portex, Smith Medical, Hythe, UK) were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters will be inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% iss initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is established and maintained throughout labor and delivery using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals, continued at the same bolus dose until delivery.

Pain was evaluated using a 0-10 cm visual analogue scale (VAS) before, 15 and 30 min after the loading dose followed by hourly assessment until delivery. VAS score assessment was based specifically on abdominal or back pain resulting from contractions. Failed epidural is defined as VAS score ≥5, 30 min after a loading dose, given after the last attempt. Women who had a repeated attempt due to VAS ≥5 at 30 min or dural puncture or required repositioning of the catheter, resulting in subsequent pain relief expressed as VAS score <5 were not considered to have a Failed epidural. VAS score is assessed by obstetrician and not the anesthesiologist who performed the block. Furthermore, intrapartum vaginal examinations to assess cervical dilatation and fetal head station were also performed by experienced obstetrician.

As part of the study, the women's satisfaction was assessed the morning following delivery using a 1-5 satisfaction scale, where score 1 corresponded to very unsatisfied and score 5 corresponded to very satisfied. Before satisfaction assessment, all women who agreed to participate signed an informed consent and then relevant data was collected from the participants' medical charts.

Study Type

Interventional

Enrollment (Anticipated)

500

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Cairo, Egypt, 12151
        • Recruiting
        • Ahmed Maged
        • Contact:
          • Ahmed Maged, MD

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

19 years to 40 years (Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

Female

Description

Inclusion Criteria:

  • ≥34 weeks of gestation
  • receiving epidural analgesia during labor,

Exclusion Criteria:

  • Women who had a planned cesarean delivery,
  • intrauterine fetal death
  • non-vertex presentation
  • delivered at less than 30 min after epidural insertion
  • contraindication for epidural analgesia (i.e., thrombocytopenia <100,000 cells/μl, ongoing thromboprophylaxis with low-molecular-weight or unfractionated heparin, and bacteremia or infection at the needle-puncture site)

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Non-Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Successful epidural anaesthesia
It is defined as VAS score <5, 30 min after a loading dose, given after the last attempt.
Women requesting epidural analgesia received a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters were routinely inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% was initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is maintained throughout labor using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals
Active Comparator: Failed epidural anaesthesia
It is defined as VAS score ≥5, 30 min after a loading dose, given after the last attempt.
Women requesting epidural analgesia received a bolus of intravenous infusion of lactated Ringer's solution before initiation of the procedure. An 18-gauge Tuohy needle and closed-tip clear catheter with three lateral orifices were used in the sitting or lateral position, with a loss-of-resistance to air technique. Epidural catheters were routinely inserted 5-6 cm inside the epidural space. A test dose of 2 ml of lidocaine 2% was initiated followed by a loading dose of 10 ml of bupivacaine 0.25%. Analgesia is maintained throughout labor using 0.125% bupivacaine with fentanyl 2 μg/ml with patient-controlled epidural analgesia by means of a continuous epidural infusion (8 ml/h basal rate) and patient-controlled boluses (3 ml each) with 20-minlock-out intervals

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
duration of first stage of labor
Time Frame: from start of cervical dilatation till full cervical dilatation
effect of success and failure of epidural on duration of first stage of labor (..before, 15 and 30 min after the loading dose followed by hourly assessment until delivery..)
from start of cervical dilatation till full cervical dilatation

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

April 30, 2017

Primary Completion (Anticipated)

December 1, 2017

Study Completion (Anticipated)

February 1, 2018

Study Registration Dates

First Submitted

April 19, 2017

First Submitted That Met QC Criteria

April 25, 2017

First Posted (Actual)

April 26, 2017

Study Record Updates

Last Update Posted (Actual)

August 2, 2017

Last Update Submitted That Met QC Criteria

July 31, 2017

Last Verified

July 1, 2017

More Information

Terms related to this study

Other Study ID Numbers

  • 168

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Vaginal Delivery

Clinical Trials on epidural anaesthesia