Measurement of the Fetal Occiput-spine Angle During the First Stage of Labor as Predictor of the Outcome of Labor

August 25, 2017 updated by: Ahmed Maged, Cairo University

Measurement of the Fetal Occiput-spine Angle During the First Stage of Labor as Predictor of the Maternal and Fetal Outcome of Labor

2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk.

The sonographer was not involved in the patient's care and the managing obstetrician was blinded to the ultrasound findings and the occiput-spine angle. For each patient of the study group, the progress of labor using a partogram ( cervical dilation ,effacement ,consistency, position and station ) and the mode of delivery were assessed retrospectively.

Study Type

Observational

Enrollment (Actual)

400

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Cairo, Egypt, 12151
        • Kasr Alainy medical school

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 35 years (Adult)

Accepts Healthy Volunteers

N/A

Genders Eligible for Study

Female

Sampling Method

Non-Probability Sample

Study Population

a total of 400 women with gestational age 37 weeks or more and history of one vaginal delivery at least

Description

Inclusion Criteria:

  1. Age between 18 & 35 years old.
  2. BMI is less than 30
  3. The gestational age between 37- 42 weeks. (calculated by LMP or 1st trimesteric U/S)
  4. Singleton pregnancy.
  5. History of one vaginal delivery.
  6. Occiputo anterior position.
  7. Active phase of first stage of labor.

Exclusion Criteria:

  1. Age (below18 or above 35).
  2. Primigravida.
  3. Occiputo posterior position.
  4. Indications of cesarean section like malpresentations , macrosomia , placenta previa, previous cesarean section .
  5. Multiple gestation.
  6. Medical disorders like hypertension, DM, liver or renal diseases

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
occiput-spine angle > or = 126
2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle > or = 126) will be performed to quantify the degree of fetal head flexion in respect to the trunk
2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk
occiput-spine angle<126
2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle < 126) will be performed to quantify the degree of fetal head flexion in respect to the trunk
2D trans abdominal ultrasound was done during the first stage of labor. If fetal position is occiput anterior and fetal presentation is vertex, two dimensional sagittal picture of the fetal head and upper spine was acquired and stored in the ultrasound machine. On this image, the offline measurement of the angle formed by a line tangential to the occipital bone and a line tangential to the first vertebral body of the cervical spine (occiput-spine angle) will be performed to quantify the degree of fetal head flexion in respect to the trunk

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
vaginal delivery
Time Frame: 24 hours
24 hours

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

July 11, 2016

Primary Completion (Actual)

July 21, 2017

Study Completion (Actual)

August 20, 2017

Study Registration Dates

First Submitted

August 25, 2017

First Submitted That Met QC Criteria

August 25, 2017

First Posted (Actual)

August 29, 2017

Study Record Updates

Last Update Posted (Actual)

August 29, 2017

Last Update Submitted That Met QC Criteria

August 25, 2017

Last Verified

August 1, 2017

More Information

Terms related to this study

Other Study ID Numbers

  • 12 (Israel lung Association)

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Vaginal Delivery

Clinical Trials on transabdominal ultrasound

3
Subscribe