Non-invasive Imaging of Muscle Structure in Duchenne Muscular Dystrophy Using Multispectral Optoacoustic Tomography (MSOT_DMD)
Non-invasive Imaging of Muscle Structure in Duchenne Muscular Dystrophy as Diagnostic and Progression Marker Using Multispectral Optoacoustic Tomography
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Bavaria
-
Erlangen, Bavaria, Germany, 91054
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
DMD-Patients
Inclusion Criteria:
- Histologic or genetically proven DMD
- Age 3-10 years
Exclusion Criteria:
-
Healthy controls
Inclusion Criteria:
- Male
- Age 3-10 years
Exclusion Criteria:
- Suspected muscular disease/myopathia
- missing informed consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Muscular Dystrophia
Multispectral Optoacoustic Tomography (MSOT) of muscles (left and right, total 8 sites) leg proximal: Musculus quadriceps, distal: Musculus triceps surae arm proximal: Musculus biceps, distal: Musculus brachioradialis
|
Non-invasive transcutaneous imaging of subcellular muscle components
|
|
Active Comparator: Healthy Volunteer
Multispectral Optoacoustic Tomography (MSOT) of muscles (left and right, total 8 sites) leg proximal: Musculus quadriceps, distal: Musculus triceps surae arm proximal: Musculus biceps, distal: Musculus brachioradialis
|
Non-invasive transcutaneous imaging of subcellular muscle components
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Muscular lipid content
Time Frame: Single time point (1 day)
|
Quantitative lipid signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD compared to healthy control Units: arbitrary units (a.u.)
|
Single time point (1 day)
|
|
Muscular collagen content
Time Frame: Single time point (1 day)
|
Quantitative collagen signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD compared to healthy control Units: arbitrary units (a.u.)
|
Single time point (1 day)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Muscular myo-/hemoglobin content
Time Frame: Single time point (1 day)
|
Quantitative myo-/hemoglobin signal derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD compared to healthy control Units: arbitrary units (a.u.)
|
Single time point (1 day)
|
|
Correlation of lipid signal with age/disease duration
Time Frame: Single time point (1 day)
|
Quantitative lipid signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with individual disease duration/age (in month)
|
Single time point (1 day)
|
|
Correlation of myo-/hemoglobin signal with age/disease duration
Time Frame: Single time point (1 day)
|
Quantitative moo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with individual disease duration/age (in month)
|
Single time point (1 day)
|
|
Correlation of lipid signal with 6MWT
Time Frame: Single time point (1 day)
|
Quantitative lipid signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with 6-minute walk test (6MWT, distance in meters, less distance means higher disease severity)
|
Single time point (1 day)
|
|
Correlation of lipid signal with MRC
Time Frame: Single time point (1 day)
|
Quantitative lipid signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with Medical Research Council (MRC, scale: 0-5, lower score means less muscular strength, measured for each individual muscles) muscle scale
|
Single time point (1 day)
|
|
Correlation of collagen signal with 6MWT
Time Frame: Single time point (1 day)
|
Quantitative collagen signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with 6-minute walk test (6MWT, distance in meters, less distance means higher disease severity)
|
Single time point (1 day)
|
|
Correlation of collagen signal with MRC
Time Frame: Single time point (1 day)
|
Quantitative collagen signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with Medical Research Council (MRC, scale: 0-5, lower score means less muscular strength, measured for each individual muscles) muscle scale
|
Single time point (1 day)
|
|
Correlation of myo-/hemoglobin signal with 6MWT
Time Frame: Single time point (1 day)
|
Quantitative myo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with 6-minute walk test (6MWT, distance in meters, less distance means higher disease severity)
|
Single time point (1 day)
|
|
Correlation of myo-/hemoglobin signal with MRC
Time Frame: Single time point (1 day)
|
Quantitative myo-/hemoglobin signal (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD correlated with Medical Research Council (MRC, scale: 0-5, lower score means less muscular strength, measured for each individual muscles) muscle scale
|
Single time point (1 day)
|
|
Signal differences left and right muscles
Time Frame: Single time point (1 day)
|
Comparison of quantitative signal levels (Units: arbitrary units (a.u.)) derived by transcutaneous Multispectral Optoacoustic Tomography (MSOT) in patients with DMD/healthy controls in right and left body muscular groups (upper and lower body)
|
Single time point (1 day)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Ferdinand Knieling, Dr., Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen
- Principal Investigator: Regina Trollmann, Prof. Dr., Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 67_18 B
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.