Guo's Aortic Arch Reconstruction: The First in Man Study of WeFlow-Arch Modular Embedded Branch Stent Graft System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Beijing, China
- Chinese PLA General Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients aged 18 to 85 years old;
- Diagnosed with aortic arch lesions requiring intervention, including true aortic arch aneurysms, pseudo-aortic arch aneurysms, dissection and ulcers involving the aortic arch;
- The length of the ascending aorta is greater than 4cm (from the junction of the aortic sinus tube to the proximal edge of the innominate artery);
- Ascending aorta diameter ≥24mm and ≤44mm;
- The diameter of the iliac artery ≥7mm ;
- The diameter of the innominate artery ≤24mm, and the length ≥20mm;
- Patients able to understand the purpose of the trial, participate in the trial voluntarily with informed consent form signed by the subject him/herself or his or her legal representative, and willing to complete follow-up visits as required under the protocol.
Exclusion Criteria:
- Patients with ascending aortic aneurysm, dissection, ulcer, hematoma;
- Experienced systemic infection during past three months;
- History of aortic valve repair or replacement;
- History of aortic surgery or endovascular repair surgery;
- Carotid artery is severely narrowed, calcified, clotted, twisted;
- Right axillary artery is severely narrowed, calcified, thrombosis, twisted;
- Heart transplant;
- Suffered MI or stroke during past three months;
- Class IV heart function (NYHA classification);
- Pregnant or breastfeeding;
- Allergies to contrast agents;
- Life expectancy less than 12 months。
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: WeFlow-Arch Moduler Embedded Branch Stent Graft System
|
The modular embedded aortic arch stent graft system consists of the embedded ascending aorta stent graft system, the arch aorta stent graft system and the branch stent system.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Rate of no major adverse events related to device or surgery
Time Frame: 30 days after surgery
|
Major adverse events related to device or surgery include: stroke, respiratory failure, pericardial tamponade, dissection or aneurysm rupture, paraplegia, stent occlusion, stent bend, stent displacement, thrombosis or rupture of the approach vessel, switch to open surgery, death, etc.
|
30 days after surgery
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Technical success rate
Time Frame: immediately after the surgery
|
Successful delivery of the stent graft conveyors to their predetermined positions, accurate positioning and successful deployment of the stent, safe removal of the delivery device outside the body.
|
immediately after the surgery
|
|
Immediate surgery success rate
Time Frame: immediately after the surgery
|
Successful delivery of the stent graft, no major adverse events related to devices or surgery.
|
immediately after the surgery
|
|
The clinical success rate
Time Frame: 12 months after the surgery
|
Clinical success rate:12 months after the operation, there was no displacement of the stent, I and III endoleak requiring treatment, aneurysm enlargement or rupture, and branch stent occlusion.
|
12 months after the surgery
|
|
The incidence rate of secondary operations within 12 months after surgery
Time Frame: 12 months after surgery
|
The incidence rate of secondary operations within 12 months after surgery.
|
12 months after surgery
|
|
Adverse event rate within 12 months after surgery
Time Frame: 12 months after surgery
|
Adverse event rate within 12 months after surgery.
|
12 months after surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- WeFlow-Arch V1.0
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Aortic Arch; Aneurysm, Dissecting
-
NCT05421130Active, not recruitingAortic Aneurysm | Aortic Dissection | Aortic Arch Aneurysm | Aortic Arch; Aneurysm, Dissecting
-
NCT03735472CompletedAortic Arch; Aneurysm, Dissecting
-
NCT03347812UnknownUlcer | Aortic Dissection | Aortic Arch Aneurysm | Pseudoaneurysm
-
NCT00583817Enrolling by invitationAortic Dissection | Ascending Aortic Dissection | Thoracoabdominal Aortic Aneurysm | Thoracic Aortic Aneurysms | Dissecting, Aneurysm | Ascending Aorta Aneurysm | Aortic Arch; Aneurysm, Dissecting | Renal Artery Aneurysm | Superior Mesenteric Artery Aneurysm
-
NCT05530304RecruitingAortic Arch Aneurysm | Aortic Arch | Dissection of Aortic Arch | Triple Branch
-
NCT07067840Not yet recruitingAortic Arch Aneurysm | Aortic Arch Pseudoaneurysm | Aortic Arch Ulcer
-
NCT07166133RecruitingAortic Arch Aneurysm | Aortic Arch Dissection
-
NCT06385379Recruiting
-
NCT04765592Active, not recruiting
Clinical Trials on WeFlow-Ach Moduler Embedded Branch Stent Graft System
-
NCT04765592Active, not recruiting
-
NCT06385379Recruiting
-
NCT05179967RecruitingJuxtarenal Abdominal Aortic Aneurysm
-
NCT04765605Active, not recruiting
-
NCT04745546UnknownJuxta Renal Abdominal Aortic Aneurysm Without Rupture
-
NCT05754541Recruiting
-
NCT07139912Not yet recruiting
-
NCT07049913RecruitingTrauma | Aneurysm Thoracic | Dissection of Aorta, Thoracic
-
NCT06710938RecruitingThoracoabdominal Aortic Aneurysms
-
NCT00893620TerminatedAorto-iliac Aneurysms | Iliac Aneurysms