Effects of Transcranial Direct Current Stimulation (tDCS) on Rotator Cuff Fatigue.
Effects of Transcranial Direct Current Stimulation (tDCS) on Rotator Cuff Fatigue. A Randomized, Sham-controlled, Double-blind, Crossover Study.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Mauro Barone, PT
- Phone Number: +54 9 3412123037
- Email: mbarone@ugr.edu.ar
Study Locations
-
-
Santa Fe
-
Rosario, Santa Fe, Argentina, 2000
- University of Gran Rosario
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age ranging between 18 to 35 years, all genders.
- Healthy subjects
- Moderate physical activity (evaluated by IPAQ questionnaire)
- Do not perform any exhausting exercise and do not drink alcoholic or caffeinated beverages during the time the work is performed.
Exclusion Criteria:
- Subjects with trauma in the last three weeks or previous surgeries on the upper extremity, patients with pre-existing neurological or rheumatic conditions, pregnancy, medical history of epilepsy the convulsive event, subjects under analgesic drug treatment or have ingested drugs with central action in the last 72 hours.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Active anodal tDCS
The direct electric current will be applied through a pair of sponges humidified with saline solution (150 mMols of NaCl diluted in water Milli-Q) on the electrodes (35 cm2).
The electrodes (anode and cathode) will be connected to a continuous electric stimulator (Model: Microestim Foco Research, Brand: NKL, Souza Cruz, Brusque - SC, Brazil), with one energy battery (9 V) and will be mounted in accordance with the International 10-20 EEG System.
For anodal polarity stimulation over the left TC, the anodal electrode will be placed over the scalp on the T3 area located at 40% of the distance on the left from the Cz point.
The cathode electrode will be placed over the contralateral supraorbital area (Fp2).
Thereafter, a constant electric current of 2 mA will be applied for 20 min.
|
The direct electric current will be applied through a pair of sponges humidified with saline solution (150 mMols of NaCl diluted in water Milli-Q) on the electrodes (35 cm2).
The electrodes (anode and cathode) will be connected to a continuous electric stimulator (Model: Microestim Foco Research, Brand: NKL, Souza Cruz, Brusque - SC, Brazil), with one energy battery (9 V) and will be mounted in accordance with the International 10-20 EEG System.
For anodal polarity stimulation over the left TC, the anodal electrode will be placed over the scalp on the T3 area located at 40% of the distance on the left from the Cz point.
The cathode electrode will be placed over the contralateral supraorbital area (Fp2).
Thereafter, a constant electric current of 2 mA will be applied for 20 min.
|
|
Sham Comparator: Sham anodal tDCS
The direct electric current will apply through a pair of sponges humidified with saline solution (150 mMols of NaCl diluted in water Milli-Q) on the electrodes (35 cm2).
The electrodes (anode and cathode) will be connected to a continuous electric stimulator (Model: Microestim Foco Research, Brand: NKL, Souza Cruz, Brusque - SC, Brazil), with one energy battery (9 V) and will be mounted in accordance with the International 10-20 EEG System.
For the sham condition, the electrodes will be placed at the same positions as for the anodal tDCS.
However, the stimulator will turn off after 30 s of stimulation.
As a result, subjects will report the same sensory feelings from the beginning of the real tDCS conditions, specifically itching and tingling feelings on the scalp for the first few seconds of tDCS, but not thereafter, whether or not the stimulation will continue or stop.
|
The direct electric current will be applied through a pair of sponges humidified with saline solution (150 mMols of NaCl diluted in water Milli-Q) on the electrodes (35 cm2).
The electrodes (anode and cathode) will be connected to a continuous electric stimulator (Model: Microestim Foco Research, Brand: NKL, Souza Cruz, Brusque - SC, Brazil), with one energy battery (9 V) and will be mounted in accordance with the International 10-20 EEG System.
For anodal polarity stimulation over the left TC, the anodal electrode will be placed over the scalp on the T3 area located at 40% of the distance on the left from the Cz point.
The cathode electrode will be placed over the contralateral supraorbital area (Fp2).
Thereafter, a constant electric current of 2 mA will be applied for 20 min.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Time to Exhaustion (TTE)
Time Frame: At baseline, after 3 and 6 days
|
To assess endurance performance, participants will perform a submaximal isometric time to exhaustion (TTE) task of the shoulder external rotator muscles at 50% of their maximal voluntary contraction (MVC), which will be performed during each visit.
During the TTE each participant will receive visual feedback on a computer monitor showing the target force.
The task will finish when their force is below the required target value for more than 3 s.
None of the participants will be aware of the time elapsed during the test and results of all the sessions will be provided only after the completion of all visits.
Participants' perception of effort will be measured using the RPE scale (Borg, 1998) every 20 s of the TTE task.
Leg muscle pain will be assessed every 20 s by using the Numerical Pain Rating Scale (NPRS).
|
At baseline, after 3 and 6 days
|
|
Change in Maximum Voluntary Contraction (MVC)
Time Frame: At baseline, after 3 and 6 days
|
After a brief standardized warm-up with submaximal isometric contractions, all participants will perform a 6 seconds MVC of infraspinatus muscle.
For the MVC, subjects will be standing, with the shoulder in adduction position and the elbow flexed at 90°.
The record will be evaluated by a load cell S200 (Miotec™, Porto Alegre, Brazil).
The MVC produced during this test will be used to calculate the participants' 50% MVC used in the subsequent TTE task of that visit.
|
At baseline, after 3 and 6 days
|
|
Change in Rating of Perceived Exertion (RPE)
Time Frame: At baseline, after 3 and 6 days
|
Borg rating of perceived exertion (RPE) is an outcome measure scale used in knowing exercise intensity prescription.
The RPE will be evaluated using the BORG CR10 scale, its ranges are from "0" (no exertion) to "10" (maximum effort).
The RPE will be evaluated using the BORG CR10 scale, its ranges are from "0" (no effort) to "10" (maximum effort).
The perception of the effort of the participants will be measured every 20 s during the TTE task.
|
At baseline, after 3 and 6 days
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Global Rating of Change Scale (GRCS)
Time Frame: After 3 and 6 days
|
For the Global Rating of Change Scale, in the second and third visit, subjects will be asked about their perception of change in relation to the endurance task relative to their status at the first visit.
|
After 3 and 6 days
|
|
Change in Electromyographic recordings (sEMG)
Time Frame: At baseline, after 3 and 6 days
|
Surface electromyography (sEMG) assessment will be performed on the infraspinatus and deltoid muscles, using an acquisition module with four analog channels (Miotec™, Biomedical Equipments, Porto Alegre, Brazil).
The conversion from analog to digital signals will be performed by an A/D board with 16-bit resolution input range, sampling frequency of 2 kHz, common rejection module greater than 100 dB, signal-noise ratio less than 03 μV Root Mean Square and impedance of 109 Ω.
The sEMG signals will be recorded through surface Ag/AgCl electrodes (Meditrace™, Canada) with a centre-to-centre distance of 2 centimeters, in a parallel orientation to the underlying muscle fibers.
A ground electrode will be placed in the lateral epicondyle of the contralateral arm The skin will be shaved and cleaned using alcohol swabs, following standardized guidelines.
A fatigue study will be carried out using a frequency analysis.
|
At baseline, after 3 and 6 days
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Cristian Mendoza, MsC, University of Gran Rosario
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- tDCS and Rotator Cuff
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.