Atrial Synchrony Evaluation of Bachmann Bundle Pacing in Sick Sinus Syndrome
Clinical Study on the Application of Two-dimensional Speckle Tracking Imaging to Evaluate the Atrial Synchrony of Bachmann Bundle Pacing in Patients With Sick Sinus Syndrome
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Hubei
-
Shiyan, Hubei, China, 442000
- Beijing AnZhen Hospital, Capital Medical University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Meets diagnostic criteria for sick sinus syndrome (e.g., persistent sinus bradycardia <50 bpm, sinus arrest, sinoatrial block, or tachy-brady syndrome).
- Age between 30 and 90 years.
- Has not taken any other antiarrhythmic drugs within one month prior to enrollment.
- Has not participated in any other related clinical trials.
- Voluntarily signs the informed consent form.
Exclusion Criteria:
- Patients with severe primary diseases causing unstable vital signs (e.g., severe circulatory, digestive, or neurological system diseases).
- Patients with a history of recurrent syncope, Adams-Stokes syndrome, severe bradycardia (lowest sinus rhythm <30 bpm), or long RR interval >3s.
- Pregnant or lactating women.
- Patients with mental illness.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Bachmann Bundle Pacing (BBP) Group
Patients were randomized to receive a permanent pacemaker with the atrial lead placed in the Bachmann bundle region.
They were followed up at 1 month and 3 months post-procedure.
|
Implantation of a permanent pacemaker system.
The atrial lead (Medtronic 3830 active electrode) is surgically positioned and fixed in the Bachmann bundle region, located at the angle between the superior vena cava and the atrium in the mid-posterior position of the high atrial septum.
Successful placement is confirmed by achieving a P-wave width shortening of at least 30ms compared to the preoperative P-wave.
The ventricular lead is positioned in the mid-to-lower portion of the ventricular septum.
Pacing parameters are measured and confirmed to be good.
|
|
Active Comparator: Right Atrial Appendage (RAA) Pacing Group
Patients were randomized to receive a permanent pacemaker with the atrial lead placed in the conventional right atrial appendage.
They were followed up at 1 month and 3 months post-procedure.
|
Implantation of a permanent pacemaker system using the conventional technique.
The atrial active electrode is surgically positioned and fixed in the right atrial appendage.
The ventricular lead is placed in the mid-to-lower portion of the ventricular septum.
Pacing parameters (sensing > 2.0mV; impedance between 300 to 1000Ω; threshold < 1.5mV) are confirmed to be good.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Inter-atrial Electromechanical Delay (Inter AEMD)
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured by two-dimensional speckle tracking imaging (2D-STI) as the time difference between the onset of the P-wave on the electrocardiogram (ECG) and the peak longitudinal strain of the lateral walls of the right and left atria.
A smaller value indicates better inter-atrial synchrony.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Intra-atrial Mechanical Delay (IAMD)
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured by 2D-STI as the standard deviation of the time-to-peak longitudinal strain of six segments of the left atrium.
A smaller value indicates better intra-atrial synchrony.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Intra-right Atrial Electromechanical Delay (Intra-right AEMD)
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured by 2D-STI as the time difference between the earliest and latest peak longitudinal strain within the right atrium segments.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in P-wave Duration (PWD) and Morphology
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured from the 12-lead surface ECG, including P-wave duration (P-AT, P-Am) and P-wave axis (P-aI, P-aL).
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in QRS Duration and Axis
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured from the 12-lead surface ECG.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Left Atrial (LA) and Right Atrial (RA) Dimensions
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured by standard 2D echocardiography.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Left Ventricular End-Systolic Diameter (LVESD) and End-Diastolic Diameter (LVEDD)
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Measured by standard 2D echocardiography.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Left Atrial Strain Parameters
Time Frame: Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
Includes left atrial reservoir strain (LASr), conduit strain (LAScd), and contraction strain (LASct), measured by 2D-STI.
|
Baseline, 1 Month Post-procedure, 3 Months Post-procedure
|
|
Recurrence of Atrial Arrhythmia
Time Frame: Up to 1 year
|
Number of patients experiencing newly developed or recurrent atrial fibrillation or atrial tachycardia.
|
Up to 1 year
|
|
Change in Atrial Pacing Threshold
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: millivolts (mV).
|
1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Atrial Sensing (P-wave amplitude)
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: millivolts (mV).
|
1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Atrial Pacing Impedance
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: Ohms (Ω).
|
1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Ventricular Pacing Threshold
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: millivolts (mV).
|
1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Ventricular Sensing (R-wave amplitude)
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: millivolts (mV).
|
1 Month Post-procedure, 3 Months Post-procedure
|
|
Change in Ventricular Pacing Impedance
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: Ohms (Ω).
|
1 Month Post-procedure, 3 Months Post-procedure
|
|
Percentage of Ventricular Pacing
Time Frame: 1 Month Post-procedure, 3 Months Post-procedure
|
Measured via pacemaker programmer interrogation.
Unit: Percentage (%).
|
1 Month Post-procedure, 3 Months Post-procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Yongquan Wu, Beijing Anzhen Hospital
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2025126x
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.