The New GlideRite DLT Stylet®: An Observational Study

February 21, 2012 updated by: Jean Bussières, Laval University
Thoracic surgeries usually require lung isolation techniques. Double-lumen tube (DLT), either right or left sided, is the most frequent tool used to realize this technique. In front of difficult airways, the use of videolaryngoscopy (GllideScope®) (GS) may advantageous. Hypothesis: We will test the hypothesis that under GS, the use of a specific semi-rigid stylet is efficacious to insert a DLT, and also safe. The increased rigidity of the GlideRite DLT Stylet for double-lumen tubes will enable the DLT to keep its form while it is railroaded into superior airways. This new stylet combined to Glidescope® utilization will increase the rate of successful intubation, especially in patients with difficult airways. This technique will allow us to directly intubate with a DLT using the GlideScope®, avoiding a beforehand SLT intubation and airway exchange catheter use. Consequently, its use could reduce risks associated to blind insertion of DLT with airway exchange catheter (airway traumatism and pulmonary aspiration). Primary objective: To determine the GlideRite DLT Stylet efficiency for double-lumen tubes orotracheal intubation under videolaryngoscopy (GllideScope®). Secondary objectives: to time successful intubation, to count the number of intubation attempt, to verify the influence of difficult intubation score (DIS) on successful intubation, and to log complications associated to its use. Exclusion criterion are: previous history of difficult intubation, anticipated difficult mask ventilation, and anticipated difficult intubation. Conclusion: The aim of using the GlideRite DLT Stylet for an orotracheal intubation under videolaryngoscopy is to allow the primary intubation with a DLT in patients with abnormal superior airways. These anomalies are more and more frequent. Alternative airway management implies more manipulations, leading to an increased risk of oxygen desaturation, lung aspiration, and airway lesions. Moreover, these alternatives take more time than using a Glidescope, which can be compare to direct laryngoscopy. The development of a semi-rigid stylet, such as the GlideRite DLT Stylet, is a great advancement in the management of primary intubation with DLT, mainly in face of difficult airways.

Study Overview

Status

Completed

Detailed Description

INTRODUCTION Anesthesia in thoracic surgery (non cardiac) often requires pulmonary isolation techniques in order to facilitate the surgery, to protect a healthy lung, and to control the ventilation. The double lumen tube (DLT), in right and left version, is the technique of choice to obtain lung isolation, whereas the bronchial blocker can also be used.

Double-lumen tube One-lung ventilation is required in most of thoracic surgeries. Many strategies can be used to achieve lung isolation: 1) use of endobronchial tube, 2) use of a single-lumen tube (SLT) and a bronchial blocker (BB),or 3) use of a double-lumen tube (DLT). There is many advantages of using a DLT: easier to position, shorter time of lung collapsing and re-expansion than BB, each lung can be suctioned/ventilated separately, and less subject to displacement than BB. Since no medical instrument is perfect, DLT has also some inconvenient: DLT are larger, and less compliant than a SLT. They also have two cuffs, one bronchial and another one tracheal. The latter is causing problem when intubating patients with teeth at the superior jaw. Precautions have to be taken to avoid rupturing the tracheal cuff. These characteristics are exaggerated when anesthesiologist faces a patient with a difficult airway. These cases are usually managed by first proceeding to a standard intubation with a SLT, second, use an airway exchange catheter (AEC) to withdraw the SLT, and then, advance the DLT into the proper position. Thereafter, the gold standard is to confirm the DLT position with a fiberoptic bronchoscope (FOB). If direct laryngoscopy provides poor glottis visualization, another option is to proceed to a FOB-assisted DLT intubation.

Video laryngoscopes Over the last decade, video laryngoscopes have been developed to handle difficult airway management. They have the advantage of improving Cormack-Lehane (CL) grade over direct laryncoscopy. Many manufacturers distribute video laryngoscopes: the Storz® C-MAC™, the McGrath® Series-5™, and the GlideScope® Video Laryngoscope™ (GVL) are few examples. This latter is frequently used in our centre to allow tracheal intubation with a SLT in numerous situations where conventional laryngoscopy is not possible. The GVL requires the same technique than a direct laryngoscopy without a line of sight, turning CL Grade III or IV into CL Grade I or II.

Stylet To facilitate the endotracheal tube (ETT) insertion using the GVL, either a semi-rigid or a malleable stylet must be used. There is also a lot of discussion about the best stylet configuration allowing the tip of the ETT to be positioned at the glottis opening and advancing the tube into the trachea, but no consensus has been obtained yet. Difficult airway management may be optimized by shaping the SLT using a malleable stylet, directing the ETT through vocal cords. The main problem of malleable stylet is that it loses its initial shape when the ETT goes through narrow airways. It is why many clinicians prefer the semi-rigid stylet when using the GlideScope®. Double-lumen tubes are already supplied with a malleable aluminum stylet in order for them to maintain their initial shape, and some authors found that accuracy of placement have improved when it is retained into a left-DLT for the entire intubation procedure.

New semi-rigid stylet Video laryngoscopes have been designed to be mostly used with SLT, but recent publications have suggested using a GlideScope® for primary DLT placement in difficult airways, as described by Hernandez, A et al. in 2005 and Chen, A et al. in 2008. Even if DLT are provided with a stylet, the technique of intubation with the GVL remains difficult, mainly because the aluminum stylet is too malleable. Verathon Inc. has marketed the GlideRite® rigid stylet, especially design to use with the GlideScope®. Its length fits most of SLT, its shape is adapted to the GVL's curvature, and the curvature can be modified to accommodate a difficult airway only with intentional movement. In collaboration with Verathon Inc., we have designed a new semi-rigid intubating stylet that can be use for primary DLT intubation with the Glidescope® Videolaryngoscope, the GlideRite DLT Stylet®. This improved intubating tool is sharing the same curve but is longer than the GlideRite® rigid stylet. It present a specific handle to fit with the DLT and to orient the distal extremity into the right or left bronchus. The new stylet fits 35 to 41 French, left of right-sided DLTs. Anticipated benefits of this new design are a shorter time required to position the DLT, less intubating attempt, lower risk of trauma to the airway, lower risk of desaturation and, lower risk of tracheal cuff' rupture, resulting in a one-step lung isolation.

HYPOTHESIS We believe that, under video laryngoscopy, the use of the semi-rigid GlideRite DLT Stylet® for primary insertion of DLT is possible.

The gain of rigidity that we have developed for the GlideRite DLT Stylet® imposes its shape to the DLT, and conserves it while the tube is guided through the superior airway. We hope that the combination of both the GlideScope® and the new semi-rigid stylet will increase the number of successful primary intubation with a double lumen tube. Furthermore, its utilization could drastically decrease associated risks of blind DLT intubation with an AEC. These risks are oxygen desaturation, pulmonary aspiration, and superior airway trauma.

OBJECTIVES The primary objective of this observational study is to determine the GlideRite DLT Stylet® efficiency during endotracheal intubation with a double lumen tube under video laryngoscopy (GlideScope®).

The secondary objectives are:

  1. To time the intubating process.
  2. To count the number of attempt to obtain a successful intubation.
  3. To verify the correlation between the difficult intubation score and a successful intubation.
  4. To note all complications associated to the GlideRite DLT Stylet® utilization.

METHODS After obtaining local REB approval, 50 patients having a thoracic surgery (non cardiac) via either thoracoscopy or thoracostomy, were enrolled to this observational study between May 14th 2010 and January 17th 2011.

Intraoperative proceeding Before anesthesia was induced, patients were pre-oxygenated in order to obtain an inspired-expired O2 gradient ≤10%. Anesthesia was performed in conformity with local practice standards. Curarization was achieved by injecting a dose of ≥1.0 mg/kg (ideal body weight) of rocuronium (Zémuron®, Merck & Co., Whitehouse Station, NJ, USA). If mask ventilation was proven to be difficult, the patient was excluded from the study. The malleable stylet was removed from the DLT (Broncho-Cath R- or L-DLT, 35 to 41Fr, Mallinckrodt Inc, St-Louis, MO, USA) and replaced with a GlideRite DLT Stylet® (Verathon Medical ULC, Burnaby, BC, Canada). Before proceeding to the intubation, curarization level was verified with a neuromuscular stimulator, absence of thumb movement when a train-of-four was applied allowed us to begin the protocol.

The timer was started when either the GlideScope® blade (Verathon Medical ULC, Burnaby, BC, Canada) was inserted between the lips and stopped when the tracheal cuff was passed through the vocal cords. In case of patients presenting with upper teeth, the timer was started when the DLT was inserted between the lips. Immediately after intubation, intratracheal position was confirmed with FOB. When a patient had teeth at the superior jaw, the DLT was inserted first into the mouth in order to avoid rupturing the tracheal cuff. External larynx manipulations were allowed at all time. If after one (1) minute, the intubation was not successful, the anesthesiologist could then modify the stylet shape. If after two (2) minutes, the intubation was still not achieved, the DLT and GVL blade were withdrawn, and mask ventilation was started again. At that time, the anesthesiologist could use the intubation technique of his choice. The position of the DLT was confirmed by the visualization of the trachea through the FOB. Throughout this process, if oxygen saturation dropped below 94%, mask ventilation was started to increase saturation up to 98% or more before another intubation could be attempted. If oxygen saturation dropped below 90%, mask ventilation was started to increase saturation up to 98% or more, the patient was then excluded from the study, and the anesthesiologist could use the intubation technique of his choice.

Statistical analysis Data obtained during the preoperative period will be correlated with the success rate, the time to achieve a successful intubation and, the number of attempt.

Study Type

Observational

Enrollment (Actual)

50

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Quebec
      • Quebec City, Quebec, Canada, G1V 4G5
        • Institut de cardiologie et de pneumologie de Québec

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Probability Sample

Study Population

50 patients having an elective thoracic surgery (non cardiac) via either thoracopscopy or thoracostomy. Patients were all 18 years old or over, and have read, understood and signed an informed consent at the preoperative evaluation or on surgery morning.

Description

Inclusion Criteria:

  • 18 years old
  • Elective thoracic surgery (non cardiac)

Exclusion Criteria:

  • history of a difficult intubation in the past
  • anticipated difficult mask ventilation
  • anticipated difficult intubation according to the anesthesiologist's evaluation

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

Cohorts and Interventions

Group / Cohort
GlideScope DLT intubation
Patients having a thoracic surgery (non cardiac) via either thoracoscopy or thoracostomy. Patients were all 18 years old or over, and have read, understood and signed an informed consent at the preoperative evaluation or on surgery morning.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of Successfull Primary Placement of the Double Lumen Tube.
Time Frame: 1 hour (Post intubation)
To evaluate the number of participants where GlideRite DLT Stylet® associated to the video laryngoscopy (GlideScope®)allowed the primary placement of the double lumen tube into their trachea.
1 hour (Post intubation)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Duration of the Intubating Process
Time Frame: 1 hour (Post intubation)
The timer was started when the GLS blade was inserted between the lips and stopped when the proximal part of the tracheal cuff was passed through the vocal cords. When a patient had teeth at the superior jaw, the DLT was first inserted into the mouth prior to the insertion of the GLS blade in order to avoid rupturing the tracheal cuff. For these cases, the timer was started when the DLT was inserted between the lips.
1 hour (Post intubation)
Number of Attempt to Obtain a Successful Intubation
Time Frame: 1 hour (Post intubation)
1 hour (Post intubation)
Correlation Between the Difficult Intubation Score and a Successful Intubation
Time Frame: 1 hour (Post intubation)
1 hour (Post intubation)
Number of Complications Associated to the GlideRite DLT Stylet® Utilization
Time Frame: 1 hour (Post intubation)
Complications defined either as oxygen desaturation below 95%, oxygen desaturation below 90%, minor bleeding, anatomic lesion.
1 hour (Post intubation)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

May 1, 2010

Primary Completion (ACTUAL)

January 1, 2011

Study Completion (ACTUAL)

January 1, 2011

Study Registration Dates

First Submitted

March 1, 2011

First Submitted That Met QC Criteria

March 2, 2011

First Posted (ESTIMATE)

March 4, 2011

Study Record Updates

Last Update Posted (ESTIMATE)

March 26, 2012

Last Update Submitted That Met QC Criteria

February 21, 2012

Last Verified

February 1, 2012

More Information

Terms related to this study

Other Study ID Numbers

  • IUCPQ-20420

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Double Lumen Tube Intubation

Subscribe