Pulmonary Functions Test in Patients After Fontan Operation

August 9, 2011 updated by: Rambam Health Care Campus

Long-term Effects on Pulmonary Function in Post- Fontan Operation

Developed in the early 1970s, Fontan Operation has provided palliative care for patients with single ventricle physiology. Single ventricle is a rare subclass of the atrioventricular (AV) alignment abnormalities double inlet and common inlet ventricles (and rarely, straddling tricuspid valve), in which there is only one ventricular sinus [1]. Most patients present with symptoms of congestion , low cardiac output, and deep cyanosis immedietly after birth. Untreated, these heart anomalies are highly lethal. Neonatal heart transplantation is implacable because of shortage of donors. Fontan operation is a three staged palliative procedure: the single ventricle pumping blood to the systemic circulation , while blood flows laminarly to the lungs through direct anastomosis of the superior and inferior vena cavae (total cavo pulmonary connections), inevitably by-passing the right heart .

This procedure has been shown to immediately correct the mixed venous blood dysfunction, providing treatment for the prominent signs of cyanosis.

Along with its beneficial outcomes, Fontan circulation patients have been documented to have a variety of post-operative late complications. Of most substantial, increased systemic vascular resistance (mean of 10-15 mmHg higher) [2], systolic dysfunction as a result of decreased preload and increase afterload [3], and atrial arrhythmias [4].

With the advent of bypassing right-heart circulation with Fontan operation, the pulmonary vascular bed is exposed to a new atmosphere of blood flow. Instead of physiological pulsatile flow in normal circulation, the pulmonary vasculature is receiving slow velocity, laminar flow [5]. Patients post-Fontan operations have been documented to have restrictive-type pulmonary function, but still yet to be correlated with Fontan circulation or as a possible result of prior lung tissue injury from the pre/intra-operation high volume blood flow. Regardless, Fontan patients are described to have decreased pulmonary function.

The purpose of this research effort is to document and analyze the pulmonary function of those patients post-Fontan operation. It is still unclear as to what the long-term effects of Fontan operation are towards the pulmonary vascular bed, leaving us questions about the effects on lung capacities, ventilation-perfusion efficiency, and oxygen saturation.

Study Overview

Status

Unknown

Conditions

Detailed Description

Generation of Data:

  1. Spirometry-Spirometry will be performed in accordance with ATS/ERS (American Thoracic Society/ European Respiratory Society) Task Force using a KoKo spirometer (KoKo system, PDS Inc., Ferraris Cardiopulmonary System Group; Louisville, CO, USA). Each maneuver will be repeated for at least three technically acceptable FEFV curves; the best results were used for analysis. [6]
  2. Whole Body Plethysmography- FRCpleth will be measured in a commercial, whole body ZAN500 constant volume body plethysmograph (ZAN-Messgeraete GmbH, Germany); the surrounded glassed cabin of 980 L includes a chair with adjustable height, all meeting the ATS/ERS recommendations for plethysmography measurements [7,8]. The flow, volume, cabin pressure, and mouth pressures are automatically calibrated. BTPS conditions for lung volumes are automatically corrected. According to the manufacturer, environmental interference is automatically reduced by a numeric-drift-compensation, enabling quick stable signals for immediate testing.
  3. MCT - Methacholine challenge tests will be performed in a designated room at the Pediatric Pulmonary Unit, Meyer Children's Hospital, Haifa, Israel. MCT was performed with double doses of fresh methacholine solutions in saline. Solutions were driven by KoKo-PDS dosimeter via mouthpiece. The MCT will end when FEV1 dropped by more 20% from baseline FEV1 values or when a methacholine concentration of 16 mg/ml was reached. The exact PC20 value will be then calculated by the program according to the log-transformed formula, as described in the guidelines for methacholine.[9] Airway hyper-reactivity was defined as PC20 <8 mg/ml. Oxygen saturation and heart rate were monitored by pulse oximetry (Nonin Wrist Ox 3100, Nonin Medical, Inc., Plymouth, MN, USA).
  4. FENO: Measurement of FENO will be performed by portable electrochemical analyzer NIOX MINO (Aerocrine AB, Smidesvägen, Sweden),[10] and according to ATS recommendations . The measurement procedure includes a deep inhalation to total lung capacity followed by exhalation for 10 seconds at a mouth flow rate of 50 mL/sec and a pressure of 10 cmH2O.[11] Analysis of Data: Subjects of study will be patients post-Fontan operation over the age of 6 years in order to fulfill the cooperation requirement necessary to obtain data. Patients should be in general good health without any ongoing acute pulmonary disease.

Study Type

Observational

Enrollment (Actual)

15

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

10 years and older (Child, Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Probability Sample

Study Population

A total number of 15 Fontan patients , aged 10 years and older , with 1-2 NYHA class functional capacity. All will have total pulmonary function tests according to recognized pulmonary protocols. Results will be normalized to age-dependent pulmonogram. Exclusion criteria includes patients with acute pulmonary illness.

Generation of Data:

  1. Spirometry-Spirometry will be performed in accordance with ATS/ERS (American Thoracic Society/ European Respiratory Society) Task Force
  2. Whole Body Plethysmography- FRCpleth will be measured
  3. MCT - Methacholine challenge tests will be performed
  4. FENO: Measurement of FENO will be performed by portable electrochemical analyzer NIOX MINO (Aerocrine AB, Smidesvägen, Sweden),[10] and according to ATS recommendations .

Description

Inclusion Criteria:

  • Fontan patient NYHA 1-2
  • Age - 10-99

Exclusion Criteria:

  • Pregnant woman
  • Acute pulmonary disease

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: Cohort
  • Time Perspectives: Prospective

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Asaad khoury, MD, Rambam Health Care Campus

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

September 1, 2011

Primary Completion (Anticipated)

March 1, 2012

Study Completion (Anticipated)

September 1, 2012

Study Registration Dates

First Submitted

August 9, 2011

First Submitted That Met QC Criteria

August 9, 2011

First Posted (Estimate)

August 10, 2011

Study Record Updates

Last Update Posted (Estimate)

August 10, 2011

Last Update Submitted That Met QC Criteria

August 9, 2011

Last Verified

August 1, 2011

More Information

Terms related to this study

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Fontan Operation

Subscribe