Characterization of Removal Capacities of the Theranova Membrane by Proteomic Investigations (DIALOMIC)

April 27, 2017 updated by: Hospices Civils de Lyon

Characterization of Proteins and Forms of Albumin Removal Capacities of the Theranova Membrane by Innovating Proteomic Investigations

Hemodialysis is the major technique of renal suppleance and membrane improvements allow an efficient depuration. During the past fifty years, improving the architecture of the membranes increased constantly the clearance of uremic toxins. Online-hemodiafiltration allowed a potential interest for decreasing morbi-mortality, but this technique is not available in all hemodialysis centers yet. Theranova membrane, by its innovating architecture, could be a valuable option for the enhancement of toxin removal in patients who are not eligible for online-hemodiafiltration techniques. Interestingly, many works pointed adsorptive capacities of dialysis membranes and these observations suggest that adsorption cannot be considered as an epiphenomenon. However, there is a lack of knowledge about the extent of its benefits in hemodialysis. The efficiency of a session of hemodialysis is routinely based on the clearance of only few generic toxins (urea, ß2-microglobulin, myoglobin). The eKT/V formula permitted to link a good depuration of urea with a better survival. EuTox described in a recent review, a large panel of middle molecules considered as uremic toxins. As there are many involved toxins, modern evaluation of hemodialysis efficiency can't be still based on the only description of ß2-microglobulin and urea removals. Inflammation status is routinely measured with blood levels of CRP. However, its accumulation is not leading to a toxicity. Many others inflammatory markers have been linked with morbidity and atherosclerosis, the main cause of mortality in ESRD patients. Obviously, removal of inflammatory markers by different dialyzers needs to be assess concomitantly but single conventional dosages are time-consuming.

A minimal albumin loss is considered as another important factor for a safe hemodialysis. Due to its multiple biological functions, albumin may be one of the most important protein for the maintenance of body homeostasis. Recent works were interested in the potential toxicity of some isoforms of the albumin and especially in chronic kidney disease. Modified forms of albumin have been linked with toxic properties and the removal of modified forms could be beneficial. Furthermore, albumin oxidation can lead to an under-estimation of albumin levels with the routinely used assay. A modern evaluation of the capacities of depuration of dialyzers clearly needs to integrate the evaluation of the clearance and generation of modified forms of albumin and proteins.

Proteomic techniques allow an interesting non-selective integrative approach. This exhaustive view would be particularly adequate for building a snapshot of blood uremic toxins, permeative and adsorptive capacities of each membrane. Due to a high sensitiveness, proteomic techniques can improve dramatically the characterization of the depuration capacities of different hemodialysis membranes considering a large range of uremic toxins especially with middle molecular weight, a large panel of inflammatory markers and modified forms of albumin. Furthermore, proteomic approach can help to build a quasi-exhaustive description of all the proteins removed by a membrane.

This project aims to compare the removal capacities of each membrane on a large range of proteins and forms of albumin (native and modified) with a highly-sensitive LC-MS/MS proteomic approach. We will also build the complete proteome of depuration of each tested membrane.

Study Overview

Study Type

Interventional

Enrollment (Anticipated)

20

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Lyon, France, 69437
        • Service de Néphrologie -Hypertension - Hémodialyse, Hôpital Edouard Herriot

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (ADULT, OLDER_ADULT)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Age ≥ 18 years old
  • Patient on hemodialysis for at least 1 year
  • Patient with a functional vascular access permitting at least 300 mL/min of blood flow.

Exclusion Criteria:

  • Running infection or other active disease (scheduled surgery, cancer, hospitalisation),
  • Catheter as vascular access,
  • Recirculation of vascular access over 10%.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: OTHER
  • Allocation: NON_RANDOMIZED
  • Interventional Model: CROSSOVER
  • Masking: NONE

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
ACTIVE_COMPARATOR: Hemodialysis with Theranova
This arm is represented by the period during which the patients will undergo dialysis with the Theranova membrane.

Theranova is a polyarylethersulfone-based hemodialysis membrane manufactured by Baxter International Corp All the dialysis sessions in this arm will be performed with the theranova membrane. This membrane will exclusively be used in hemodialysis.

Modalities of hemodialysis : Blood flow: 300-400 mL/min; Dialysate flow: 500-800 mL/min

ACTIVE_COMPARATOR: Hemodialysis with FX1000
This arm is represented by the period during which the patients will undergo dialysis with the FX1000 membrane.

FX1000 is a helixone-based membrane manufactured by Fresenius All the dialysis sessions in this arm will be performed with the FX1000 membrane. This membrane will be used in hemodialysis.

Modalities of hemodialysis: Blood flow: 300-400 mL/min ; Dialysate flow: 500-800 mL/min

ACTIVE_COMPARATOR: Hemodiafiltration with FX1000
This arm is represented by the period during which the patients will undergo dialysis with the FX1000 membrane.
FX1000 is a helixone-based membrane manufactured by Fresenius All the dialysis sessions in this arm will be performed with the FX1000 membrane. This membrane will be used in hemodiafiltration Modalities of hemodialysis: Blood flow: 300-400 mL/min; Dialysate flow: 500-800 mL/min ; post reinjection convection volume of at least 25L.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Comparison of Theranova and FX1000 in high-flux hemodialysis on whole proteome of depuration (qualitative and semi-quantitative description of all the proteins depurated by absorption and convection)
Time Frame: Proteome is evaluated after an 8-weeks session of use of each membrane
Semi-quantitative analysis is based on the adondance relative of the protein detected on the spectra from the mass spectrometry assay. Quantity will be extrapoled from the level of B2-microglobulin which will be previously assayed in the original samples.
Proteome is evaluated after an 8-weeks session of use of each membrane

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Comparison of Theranova, FX1000 in high-flux hemodialysis and FX1000 in online-hemodiafiltration on differential depuration capacities among albumin isoforms, albumin loss in the dialysate and adsorbed onto the membranes
Time Frame: Isoforms of albumin are evaluated at week 1 and week 8 of use of each membrane and before and after a hemodialysis session during week 1
Mass excess will be assayed from each amino acid of albumin peptide. This mass excess will be linked with a specific adduct and percentage of presence of each adduct will be calculated.
Isoforms of albumin are evaluated at week 1 and week 8 of use of each membrane and before and after a hemodialysis session during week 1
Comparison of Theranova and FX1000 in high-flux hemodialysis on quantitative removal of protein-bounded toxins and quantitative distribution of inflammatory markers removed by dialysis.
Time Frame: Evaluation after a 8-weeks session of use of each membrane
Protein-bounded toxins: indoxyl sulfate, p-cresyl sulfate, indole-3 acetic acid - liquid chromatography Inflammatory markers : ET-1, RANTES, MIP-1alpha, MIP-1ß, Eotaxin, MCP-1, Fractalkin, IL-1, IL-2, IL-6, IL-8, IL-10, IL-18, TNF-alpha, C5a, C3a, Factor D, sICAM-1, sVCAM-1, sE-selectin, PAI-1, sFlt-1 - Luminex assay
Evaluation after a 8-weeks session of use of each membrane
Comparison of eKT/V of urea and ß2-microglobulin, removal rates and amount in the dialysate of ß2-microglobulin and myoglobin.
Time Frame: Evaluation after a 8-weeks session of use of each membrane
Evaluation after a 8-weeks session of use of each membrane
Comparison of serum albumin level after 8 weeks of hemodialysis with (Theranova in hemodialysis, FX1000 in online-hemodiafiltration, FX1000 in hemodialysis)
Time Frame: Evaluation after a 8-weeks session of use of each membrane
Evaluation after a 8-weeks session of use of each membrane

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (ANTICIPATED)

July 1, 2017

Primary Completion (ANTICIPATED)

April 1, 2018

Study Completion (ANTICIPATED)

April 1, 2018

Study Registration Dates

First Submitted

April 27, 2017

First Submitted That Met QC Criteria

April 27, 2017

First Posted (ACTUAL)

May 2, 2017

Study Record Updates

Last Update Posted (ACTUAL)

May 2, 2017

Last Update Submitted That Met QC Criteria

April 27, 2017

Last Verified

April 1, 2017

More Information

Terms related to this study

Other Study ID Numbers

  • 69HCL17_0144

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Dialysis Membrane Reaction

Clinical Trials on Hemodialysis with Theranova

Subscribe