Impact of Predilatation Between Self-expanding Valves (DIRECTII)

December 19, 2023 updated by: Konstantinos Toutouzas, National and Kapodistrian University of Athens

Impact of Balloon Predilatation Between Self-expanding Valves in All Comers Undergoing TAVI

A Multicenter, prospective, non-randomized, trial evaluating the safety and clinical efficacy of the next-generation, self-expandable Boston Scientific ACURATE NEO/TF Transcatheter Heart Valves, implanted in patients with severe aortic stenosis and the impact of predilatation in comparison with the Medtronic CoreValve EvolutT R/PRO systems from the DIRECT trial.

Study Overview

Detailed Description

The aim of the present prospective, multicenter, non-randomized trial is to compare the device success rate and the in-hospital and 30-day safety and echocardiographic clinical outcomes between TAVI with and without predilatation in all comers undergoing implantation of self-expanding valves. Primary endpoint will be device success rate as defined by the VARC-2 criteria. Secondary endpoints involve the composite endpoint of early safety at 30 days, according to the VARC-2 definitions, specifically all cause mortality, cardiovascular mortality, stroke, acute kidney injury, life-threatening or disabling bleeding, major vascular complication, as well as the echocardiographic outcomes and valve performance as designated by the VARC-2 definitions at 30 days. VARC-1 and VARC-3 device success rates will be estimated as well.

Study type: Observational

Estimated Enrollment: 75 patients

Allocation: Non - randomized, all comers

Primary Purpose: Treatment

Observational Model: Case-Control

Condition or disease: Aortic valve stenosis

Intervention/Treatment: Device: Boston Scientific ACURATE neoTM transfemoral TAVI system

Time Perspective: Prospective

Participating centers: Hippokration Hospital (Athens, Greece), Silesian Center for Heart Diseases (Zabrze, Poland), Athens Naval Hospital (Athens, Greece). It is possible that the number of the participating center may change.

Methods: Patients treated with the Boston Scientific ACURATE NEO/TF system will be prospectively. All patients will be followed for at least 30 days.

Study Type

Interventional

Enrollment (Actual)

78

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Athens, Greece, 11527
        • Hippocration Hospital First Department of Cardiology, University of Athens, Medical School

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patient with severe symptomatic aortic stenosis defined by a mean aortic gradient > 40 mmHg or peak jet velocity > 4.0 m/s or an aortic valve area (AVA) < 1cm2 or AVA indexed to body surface area (BSA) of <0.6 cm2/m2
  • Patient is symptomatic (heart failure with New York Heart Association (NYHA) Functional Class > I, angina or syncope)
  • Patients are considered at high risk for mortality with conventional surgical aortic valve replacement as assessed by a Heart Team consisting of a cardiologist and surgeon or as confirmed by a logistic EuroSCORE I ≥ 20% and / or EuroSCORE II ≥ 7% STS score ≥ 8% OR
  • Over 80 years old OR
  • Over 65 years old with 1 or 2 (but not more than two) from the following criteria:

Liver cirrhosis (Class A or B). Pulmonary insufficiency: VMS<1 liter. Previous heart surgery (CABG, vascular surgery). Porcelain aorta. Pulmonary artery systolic pressure >60 mmHg and high risk for heart surgery. Relapsing pulmonary embolism. Right ventricular insufficiency. Thoracic wall injuries that contraindicate an open heart surgery. History of radiation therapy of the mediastinum. Connective tissue disease that contraindicates an open heart surgery. Frailty/cachexia.

  • Aortic valve diameter of ≥20mm and ≤2 9mm as measured by echo.
  • Ascending aorta diameter ≤ 43 mm at the sinotubular junction.
  • Arterial aorto-iliac-femoral axis suitable for transfemoral access as assessed by conventional angiography and/or multi-detector computed tomographic angiography (access vessel diameter ≥ 6mm)
  • Patient understands the purpose, the potential risks as well as benefits of the trial and is willing to participate in all parts of the follow-up
  • Patient has given written consent to participate in the trial

Exclusion Criteria:

  • A known hypersensitivity or contraindication to any of the following which cannot be adequately pre-medicated: aspirin or heparin and bivalirudin, ticlodipine and clopidogrel, nitinol (titanium or nickel), contrast media
  • Ongoing sepsis, including active endocarditis.
  • Any percutaneous coronary or peripheral interventional procedure with a bare metal or drug eluting stent performed within 30 days prior to Heart Team assessment.
  • Echocardiographic evidence of LV or LA thrombus.
  • Mitral or tricuspid valve insufficiency (> grade II).
  • Previous aortic valve replacement (mechanical or bioprosthetic).
  • Recent (within 6 months of Heart Team assessment) cerebrovascular accident (CVA) or transient ischemic attack (TIA).
  • Patients with:

Femoral, iliac or aortic vascular disease (stenosis etc) that precludes the insertion of a transcatheter sheath.

OR Symptomatic carotid or vertebral artery disease (> 70% stenosis).

  • The patient has a bleeding diathesis, coagulopathy or denies blood transfusion.
  • Estimated life expectancy of less than 12 months due to associated non-cardiac co-morbid conditions.
  • Creatinine clearance < 20 ml/min.
  • Active gastritis or gastrointestinal ulcer.
  • Pregnancy.
  • Severe left ventricular dysfunction with left ventricular ejection fraction (LVEF) < 20%.
  • Unicuspid aortic valve.
  • Mixed aortic valve disease (aortic stenosis and aortic regurgitation> 2+).
  • Liver failure (Child-Pugh class C).
  • Severe dementia (resulting in either inability to provide informed consent for the study/procedure, prevents independent lifestyle outside of a chronic care facility, or will fundamentally complicate rehabilitation from the procedure or compliance with follow-up visits).
  • Extreme aortic valve calcification and calcific asymmetry (Agatston score: grade 4 AgS>5000 AU).
  • Aortic valve area of < 0.4 cm2.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Non-Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Other: Patients treated with Medtronic CoreValve/ Evolut R/Pro
TAVI patients treated with Medtronic CoreValve /Evolut R - Evolut PRO Transcatheter Heart Valves, participated in the DIRECT trial
Transcatheter implantation of the heart valve device Medtronic Evolut R/Pro in patients suffering from severe aortic stenosis and are candidates for this operation
Other Names:
  • Medtronic CoreValve /Evolut R/Pro
Active Comparator: Patients treated with ACURATE neo/TF
TAVI patients treated with ACURATE neo/TF Transcatheter Heart Valve recruited prospectively.
Transcatheter implantation of the heart valve device ACURATE neo/TF in patients suffering from severe aortic stenosis and are candidates for this operation
Other Names:
  • Boston Scientific ACURATE neo/TF

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Device success
Time Frame: 30 days
ACURATE NEO/TF device implantation success rates, as designated by the VARC-2 criteria
30 days

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
All cause Mortality
Time Frame: 30 days
Death teates during the hospitalization of the patient, as designated by the VARC-2 criteria
30 days
All stroke
Time Frame: 30 days
Cerebrovascular accident rates during and after the hospitalization of the patient, as designated by the VARC-2 criteria
30 days
New pacemaker implantation
Time Frame: 30 days
New pacemaker implantation rates during and after the hospitalization of the patient, as designated by the VARC-2 criteria
30 days
Major Vascular complications
Time Frame: 30 days
Vascular complications rates during and after the hospitalization of the patient, as designated by the VARC-2 criteria
30 days
Echocardiographic endpoint
Time Frame: 30 days
Echocardiographic endpoint (Post TAVI aortic valve area in cm2)
30 days
Post-dilatation
Time Frame: 30 days
Post-dilatation rates
30 days
Major Bleeding
Time Frame: 30 days
Major bleeding during and after the hospitalization of the patient, as designated by the VARC-2 criteria
30 days
Acute kidney injury stage 2 or 3
Time Frame: 30 days
AKI stage 2 or 3 during and after the hospitalization of the patient, as designated by the VARC-2 criteria
30 days
Device success
Time Frame: 30 days
ACURATE NEO/TF device implantation success rates, as designated by the VARC-1 and VARC-3 criteria
30 days

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

September 17, 2019

Primary Completion (Actual)

April 1, 2021

Study Completion (Actual)

July 20, 2022

Study Registration Dates

First Submitted

October 30, 2019

First Submitted That Met QC Criteria

November 6, 2019

First Posted (Actual)

November 8, 2019

Study Record Updates

Last Update Posted (Actual)

December 26, 2023

Last Update Submitted That Met QC Criteria

December 19, 2023

Last Verified

December 1, 2023

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Aortic Stenosis

Clinical Trials on Transcatheter Aortic Valve Implantation with Medtronic CoreValve /Evolut R/Pro

Subscribe