- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT04202237
Using the Speckle Doppler to Quantify Blood Flow in Kidney and Pancreas Grafts
Using the Speckle Doppler to Quantify Perfusion Quality in Kidney and Pancreas Grafts on Vascular Reperfusion
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
BACKGROUND After reperfusion in solid organ transplantation, the quality of organ reperfusion is often assessed visually and reported as good, moderate, reasonable, patchy or poor. In our centre a Renogram is usually performed which uses radioactive tracer which most kidney transplant recipients would have within 24 hours after transplantation to assess the overall perfusion of the allograft. The Speckle Laser Doppler is a powerful clinical tool to obtain full field, high resolution images of microvascular perfusion of an organ It has been used in many medical fields such as dermatology vascular medicine and neurosciences both in a research and in clinical settings. This study seeks to utilise this technique to try to accurately quantify perfusion in the kidney and pancreas after transplantation and to develop a robust numerical quantification system of reporting on organ perfusion.
The Speckle Laser Doppler blood flow imager uses the laser speckle contrast technique to deliver real-time blood flow images with numerical physical data, providing outstanding performance in a wide range of pre-clinical and clinical research applications. This technique has not yet been applied for the assessment of kidney transplant perfusion reporting.
RESEARCH QUESTION/AIM(S)
To evaluate the use of the laser blood flow imager in both kidney and pancreas transplantation and obtain real time video images with physical parametric data of the blood flow of transplanted organs at the time of transplantation as a proof of principle study to accurately quantify the blood flow rate either in the whole transplanted organ or a specific area of interest so as to develop a robust numerical quantification system of reporting on the perfusion of the transplanted organ. While this technique has been used in neurosurgery and other clinical settings it has not been evaluated before in a transplant setting.
.
- Measure the markers of inflammation (Hypo perfusion) and oxidative stress and attempt correlation with the quality of perfusion obtained.
Objectives
This study aims to utilise this technique to try to accurately quantify perfusion in the kidney and pancreas after transplantation and to develop a robust numerical quantification system of reporting on organ perfusion
Outcome Circulating markers of hypo perfusion and kidney injury will be measured to include: lactate, glutamate, pyruvate, Interleukin 6 as well as glutathione a marker of oxidative stress and assess their correlation with outputs from the two devices.
RATIONALE This study seeks to utilise this technique to try to accurately quantify perfusion in the kidney and pancreas after transplantation and to develop a robust numerical quantification system of reporting on organ perfusion.
The moorFLPI-2 blood flow imager uses the laser speckle contrast technique to deliver real-time blood flow images with numerical physical data, providing outstanding performance in a wide range of pre-clinical and clinical research applications. This technique has not yet been applied for the assessment of kidney transplant perfusion reporting.
STUDY DESIGN and METHODS of DATA COLLECTION AND DATA ANALYIS Speckle Doppler The Speckle Laser Doppler blood flow imager will be used to obtain real-time blood flow images at reperfusion and immediately thereafter this imaging will occur immediately after the surgery when the patient is still under anaesthetic it will take approximately 15 minutes. Initially these images with the flow parametric data will be stored on a laptop which comes with the rental equipment. However once the study is complete, all images and data will be stored on a desktop/drive in the department along with other departmental research data confidentially. The software integrated in the equipment incorporates multiple blood flow parameters and a statistical analytical package for an exhaustive analysis of various parameters. The Speckle Laser Doppler has two low power visible aiming lasers that indicate the approximate centre of the image. The aiming lasers will appear as a single point at a distance of 25 cm. As the distance is increased or decreased from 25 cm, the aiming lasers will appear as two separate points with the centre of the image being located at the midpoint between them. The aiming lasers can be turned on or off by pressing the button on the scan head or from the System Setup window in the PC software.
The moorFLPI-2 measurement software provides two measurement modes that can be used separately or in combination:
- Multi-image measurement mode.
- Single point measurement mode. The multi-image mode setting will be used as it measures flux over regular timed intervals and that is what is required for us to quantify the perfusion as compared to a single point measurement mode which measures the average flux at a single point in time.
Blood samples Concurrently blood samples will be obtained on each patient on Day 0 (day of transplantation), after reperfusion to measure markers of hypo perfusion and kidney injury: lactate, glutamate, pyruvate, Interleukin 6 as well as glutathione a marker of oxidative stress
Clinical Follow up
Patients will be monitored for 3 years following their transplant to look for any transplant related problems which may relate to the quality of the organ as assessed by speckle Doppler.
Sample size and Statistical analysis This is an exploratory study to evaluate the use of Doppler in kidney transplants and as such sample size is mainly dictated by pragmatic considerations and what is available for the duration of hiring the device. Nevertheless sample of 68 is sufficient to provide reasonable precision for the agreement and correlation tests intended for this study in an exploratory level. The analyses will be mainly descriptive. Tests will be exploratory and in the view of generating information for future larger studies.
Research Q1 The software integrated in the equipment incorporates multiple blood flow parameters and a statistical analytical package for an exhaustive analysis of various parameters. The comparison between the 2 methods for measuring blood flow will be assessed for agreement using the appropriate statistical methodology.
The continuous variables for markers of inflammation, circulating markers of hypo perfusion and oxidative stress will also be assessed for any correlation with speckle Doppler perfusion measurements.
Events at the end of 3 years follow up will be compared with the blood flow measurements in categorical analysis.
STUDY SETTING Our unit performs the largest number of kidneys transplants in the UK so has access to a large number of samples for this project.
All members of the team have academic track records and participate in several on-going research projects. Current research projects are investigating cardiovascular disease, kidney perfusion, and MR imaging.
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
Greater Manchester
-
Manchester, Greater Manchester, United Kingdom, M13 9WL
- Manchester University NHS Foundationn Trust
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
This study plans to recruit all recipients of, both kidney and pancreas transplants within a 14-week course of the study (Period of Lease of the Speckle Laser Doppler).
It is expected that approximately n=60 kidney transplants (Living Donor, DBD and DCD and Marginal Kidneys) and n=8 pancreas transplant patients will be recruited in this study period.
This will provide a range of grafts of varying quality of perfusion for assessment
Description
Inclusion Criteria:
Inclusion Criteria:
Kidney Transplant Recipients
- Age between 18 and 75 years
- English Speaking as no funding for translators available
- Able to provide written informed consent
- Receiving a kidney transplant at Manchester University NHS Foundation Trust
Pancreas Transplant Recipients
- Age between 18 and 75 years
- English Speaking as no funding for translators available
- Able to provide written informed consent All individuals will be considered for inclusion in this study regardless of age, disability, gender reassignment, marriage and civil partnership, pregnancy and maternity, race, religion and belief, sex, and sexual orientation except where the study inclusion and exclusion criteria EXPLICITLY state otherwise.
Exclusion Criteria:
Exclusion criteria
- Outside of stated age range. Aged 76+
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To evaluate the use of the laser blood flow imager in both kidney and pancreas transplantation
Time Frame: 3 months
|
Doppler imaging of kidneys and pancreas
|
3 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measure the markers of inflammation ng/ml Hypo perfusion and oxidative stress (ng/ml) and attempt correlation with the quality of perfusion obtained
Time Frame: 6-12 months
|
Circulating biomarkers of inflammation and oxidative stress
|
6-12 months
|
Collaborators and Investigators
Investigators
- Principal Investigator: Titus Augustine, FRCS, Manchester University Foundation Trust
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
- B00075
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Kidney Transplant Failure and Rejection
-
Charite University, Berlin, GermanyCompletedKidney Transplant Rejection | Antibody-mediated Rejection | Kidney Transplant FailureGermany
-
Hospital de Clinicas de Porto AlegreActive, not recruitingKidney Transplant Infection | Kidney Transplant Rejection | Kidney Transplant Failure | Kidney Transplant Failure and RejectionBrazil
-
University of MinnesotaCompletedKidney Transplant Rejection | Kidney Transplant; Complications | Transplant; Complication, Rejection | Kidney Transplant Failure and Rejection | Transplant DysfunctionUnited States
-
Columbia UniversityVeloxis PharmaceuticalsCompletedRenal Transplant Rejection | Kidney Transplant Failure and RejectionUnited States
-
University of Erlangen-Nürnberg Medical SchoolCharite University, Berlin, Germany; University Hospital, EssenActive, not recruitingKidney Transplant Rejection | Kidney Transplant FailureGermany
-
University of MinnesotaWithdrawnKidney Transplant Rejection | Kidney Transplant; Complications | Kidney Transplant FailureUnited States
-
Universitaire Ziekenhuizen KU LeuvenActive, not recruitingKidney Transplantation | Kidney Transplant Rejection | Kidney Transplant FailureBelgium
-
Northwestern UniversityNot yet recruitingKidney Transplant; Complications | Kidney Transplant Failure and Rejection
-
California Institute of Renal ResearchUniversity of California, San Diego; Balboa Institute of TransplantationRecruitingKidney Transplant; Complications | Kidney Transplant Failure and RejectionUnited States
-
Tongji HospitalNot yet recruitingKidney Transplant Dysfunction | Kidney Transplant Failure and Rejection | Transplantation, Kidney
Clinical Trials on Speckle Doppler imaging
-
Medical University of ViennaCompleted
-
University of California, IrvineBeckman Laser Institute University of California IrvineCompleted
-
University of California, IrvineChildren's Hospital of Orange CountyWithdrawn
-
M.D. Anderson Cancer CenterNational Institute of Neurological Disorders and Stroke (NINDS); National Institutes...Withdrawn
-
Royal Devon and Exeter NHS Foundation TrustUniversity of ExeterRecruiting
-
Beijing HospitalUnknownCoronary Artery Disease | Echocardiography, Three-DimensionalChina
-
Maasstad HospitalCompleted
-
Dynamic LightBarrow Neurological InstituteCompletedAneurysm, AVM, Dural Arteriovenous Fistula, Glioma, Meningioma, Metastasis, BypassUnited States
-
Seoul National University HospitalSeoul National University Bundang Hospital; Chungnam National University HospitalActive, not recruitingHeart Failure | Echocardiography | Heart Failure AcuteKorea, Republic of
-
University Hospital Inselspital, BerneCompletedGlioma | Aneurysm | Metastasis | Meningioma | AVM | Dural Arteriovenous FistulaSwitzerland