Relation of Non-invasively Measured Parameters to Clinical Outcomes in CHF Patients

December 9, 2021 updated by: Biobeat Technologies Ltd.

Relation of Non-invasively Measured Advanced Hemodynamic Parameters to Clinical Outcomes in Heart Failure Patients

Our aim is to assess whether changes in CO, CI and SVR as measured using the Biobeat wearable, wireless, non-invasive device during IV diuretic administration in an outpatient setting among CHF patients correlate with short-term clinical change measured using symptoms questionnaires, change in weight and urine output. We will also assess the correlation between baseline values of those parameters and long-term clinical outcomes, measured by HF hospitalizations and the change in disease perception and quality of life reported in questionnaires.

Study Overview

Status

Completed

Intervention / Treatment

Detailed Description

Heart failure (HF) is a common clinical syndrome resulting from structural and/or functional cardiac abnormality. It affects 2.2% of American adults and over 12% of Americans ≥80 years of age, and its total cost in the US was estimated at $30.7 billion in 2012. As prevalence and overall cost are expected to considerably rise in the coming years, HF continues to constitute a major burden to global health.

HF is characterized with a progressive course of disease with high hospital readmission rates, which account for a major portion of the economic burden. Improving the management of congestion has been a crucial component in the efforts to reduce hospitalizations. Congestion is a cardinal manifestation of HF, presenting with dyspnea, orthopnea, and edema due to volume overload. Diuretics remain a cornerstone in the management of congestion; however, there are no clear guidelines on how to adjust their administration. Guidelines recommend monitoring of daily weight changes, but efficacy is debatable. Thus, there is a pressing need to find reliable markers to promptly recognize deteriorations and help tailor diuretic treatment to prevent them. To date, European Society of Cardiology (ESC) guidelines recommend two invasive monitoring approaches to guide management, one based on invasive wireless pulmonary artery pressure monitoring and the other on utilizing data from Implantable Cardioverter Defibrillators (ICDs). Hemodynamic monitoring using invasive right heart catheterization has not shown benefit in management of HF decompensations, and nowadays is reserved only for specific clinical scenarios. In the field of non-invasive monitoring, research efforts have focused on analyzing lung impedance, ECG , and heart sounds with some promising results; a recent study utilized machine learning to generate a personalized alert system, but with a limited number of parameters monitored. Nevertheless, their algorithm's success in predicting hospitalizations reflects the importance of recognizing the heterogeneity of HF and the advantages of an individualized approach.

In this study, we will examine the use of a non-invasive, user-friendly device (BB-613WP, Biobeat Technologies LTD, Petah Tikva, Israel), in advanced HF patients receiving IV diuresis in a hospital outpatient clinic. The device can derive measurements of several parameters, including cardiac output (CO), cardiac index (CI), blood pressure (BP) and systemic vascular resistance (SVR) using photoplethysmography (PPG) technology, and has been tested in several clinical trials. We wish to assess if CO, CI and SVR can be utilized as markers for HF clinical course, so they can ideally be used to intervene and modify treatment prior to a deterioration.

The literature describing the effects of diuresis on CO and SVR is rather limited and archaic. Most studies found a reduction in CO and a rise in SVR after diuresis, but some describe the opposite, and some describe a response changing over time. This can be explained when considering that the pathophysiology underlying the effects of volume status on cardiac performance in HF is complex. The classically described Frank-Starling principle states that contractility peaks at a muscle length that allows for optimal overlap of actin and myosin filaments and maximal calcium ions sensitivity. Up to a certain point, the longer the muscle is (represented as larger EDV, end diastolic volume), the higher the force of contraction. But beyond that length, the contractile force decreases. Since different patients are characterized with different levels of cardiac filling, volume reduction induced by diuresis may have a different impact on CO, depending on the position on the Frank Starling curve. For instance, impaired ventricular filling in HF with preserved ejection fraction can reduce systolic function, due to less effective contraction in low EDV. Similarly, SVR, which is inversely proportional to CO, is likely to be affected differently. Our primary objective is to assess whether the changes in CO, CI and SVR during IV diuretic administration correlate with short-term clinical change measured using symptoms questionnaires, change in weight and urine output. Our secondary objective is to assess the correlation between baseline values of those parameters and long-term clinical outcomes, measured by HF hospitalizations and the change in disease perception and quality of life reported in questionnaires.

Study Type

Observational

Enrollment (Actual)

50

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Jerusalem, Israel, POB 12000
        • The Hadassah Ein Kerem Medical Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 120 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

50 patients >18 years of age, diagnosed with heart failure, arriving to Hadassah Ein Kerem outpatient clinic to receive IV diuresis, will be enrolled in the study

Description

Inclusion Criteria:

  • Diagnosis of heart failure
  • A Recent echocardiography report (from the last 2 year)
  • Treatment with IV diuresis at Hadassah Ein Kerem outpatient clinic

Exclusion Criteria:

  • Patient does not give consent to participate in the study, or is unable to give consent due to cognitive or mental impairment
  • Patient is under 18 years old
  • Patient is unable to answer questions regarding his condition
  • Pregnant women
  • Worker from Hadassah Medical Center

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To assess whether the changes in vital signs during IV diuretic administration correlate with short-term clinical change.
Time Frame: 4-10 hours per patient
To assess whether the changes in CO, CI and SVR measured by a wearable wireless non-invasive device during IV diuretic administration correlate with short-term clinical change measured using symptoms questionnaires, change in weight and urine output.
4-10 hours per patient

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
To assess the correlation between baseline values and long-term clinical outcomes.
Time Frame: 2 years
We will assess the correlation between baseline values of those parameters and long-term clinical outcomes, measured by HF hospitalizations and the change in disease perception and quality of life reported in questionnaires.
2 years

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Dean Nachman, MD, The Hadassah Ein Kerem Medical Center, Jerusalem, Israel

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

September 10, 2020

Primary Completion (Actual)

November 10, 2021

Study Completion (Actual)

December 10, 2021

Study Registration Dates

First Submitted

September 8, 2020

First Submitted That Met QC Criteria

September 8, 2020

First Posted (Actual)

September 14, 2020

Study Record Updates

Last Update Posted (Actual)

December 10, 2021

Last Update Submitted That Met QC Criteria

December 9, 2021

Last Verified

December 1, 2021

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

UNDECIDED

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Congestive Heart Failure

Clinical Trials on Short term monitoring

3
Subscribe