- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT04585568
Validation of Ballistocardiographic Biosensors and Other Hemodynamic Measures for Healthy Subjects
Validation and Comparison of Ballistocardiographic Biosensors and Other Hemodynamic Measures for Healthy Subjects During Different Situations
Ballistocardiographic (BCG) biosensors reflecting the patients' current state is established. There are few studies documenting BCG biosensors efficacy, effectiveness, and efficiency. In addition, technologies using invasive blood pressure curves and Near Infrared Regional Spectrometry (NIRS) to measure hemodynamics have been used. Using these technologies to guide clinical decisions may be an major advance for patients with acute and chronic diseases. The investigators will explore how these technologies compares to well established technologies measuring vital signs of healthy subjects. The investigators will use live continuous and non-continuous biosensor data to monitor the development of vital parameters during different scenarios. The study will document how CPD measured by biosensors, cerebral oximetry measured by NIRS, and invasive blood pressure curves measured by FloTrac™ are compared to established technologies of vital organ functionality.
Data will be measured continuously and documented simultanuously with technologies such as Doppler Echocardiography, transthoracic impedance (TTI), Electrocardiogram (ECG), invasive blood pressure [cardiac output/index (CO/CI), stroke volume/stroke volume index (SV/SVI), stroke volume variation/pulse pressure variation (SVV/PPV), systemic vascular resistance/ systemic vascular resistance index (SVR/SVRI), mean arterial pressure (MAP)], pulse oximetry (SpO2) and cerebral oximetry (rSO2). Of special interest is to document how relative heart stroke volume reflects blood flow documented by the parallel technology measures. All these measures are the key part in the study to document user friendliness, accuracy, sensitivity, specificity and correlations.
The main research question is whether adding BCG biosensor measures, cerebral oximetry and invasive blood pressure to monitor vital signs will add meaningful information to the care of patients in a situation where we are able to control all the factors that may impact these measures. The aim of the study is to document (correlation, sensitivity and specificity) how BCG biosensors perform compared to each other and to well established technologies used for monitoring blood flow, blood pressure, heart rate and respiration rate in steady state and during ambulance transport. In addition, the investigators will in a controlled manner measure how established maneuvers like Trendelenburg, hypo-/hyperventilation, and bolus of fluid influences our measures.
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Ballistocardiographic (BCG) biosensors collecting continuous physiological data (CPD) in real time to generate information reflecting the patients' current state is established and have become more useful in monitoring vital signs of subjects and patients. There are few studies documenting BCG biosensors efficacy, effectiveness, and efficiency. Using CPD to guide clinical decisions may be a major advance for patients with acute and chronic diseases. In addition, technologies using invasive blood pressure curves and Near Infrared Regional Spectrometry (NIRS) to measure hemodynamics have been used. This may drive the evolution from episodic to continuous patient care for these patients experiencing a severe medical event compromising blood flow. The investigators will explore how these technologies compares to well established technologies measuring vital signs of healthy subjects. In the present study the investigators will use live continuous and non-continuous biosensor data to monitor the development of vital parameters during different scenarios. The study will document how CPD measured by biosensors, cerebral oximetry measured by NIRS, and invasive blood pressure curves measured by FloTracTM are compared to established technologies of vital organ functionality.
In the present study data will be measured continuously and in phases of the study simultaneously with other well established technologies such as Doppler Echocardiography, transthoracic impedance (TTI), Electrocardiogram (ECG), invasive blood pressure [cardiac output/index (CO/CI), stroke volume/stroke volume index (SV/SVI), stroke volume variation/pulse pressure variation (SVV/PPV), systemic vascular resistance/ systemic vascular resistance index (SVR/SVRI), mean arterial pressure (MAP)], pulse oximetry (SpO2) and cerebral oximetry (rSO2). Based on this the investigators believe they will be able to pick up how dynamic differences develop. Of special interest is to document how relative heart stroke volume reflects blood flow documented by the parallel technology measures. HRV will also be evaluated in the light of other measures such as pulse, respiration, and relative stroke volume. All these measures are the key part in the study to document user friendliness, accuracy, sensitivity, specificity and correlations.
The main research question is whether adding BCG biosensor measures, cerebral oximetry and invasive blood pressure to monitor vital signs will add meaningful information to the care of patients in a situation where we are able to control all the factors that may impact these measures. The aim of the study is to document (correlation, sensitivity and specificity) how BCG biosensors perform compared to each other and to well established technologies used for monitoring blood flow, blood pressure, heart rate and respiration rate in steady state and during ambulance transport. In addition, the investigators will in a controlled manner measure how established maneuvers like Trendelenburg, hypo-/hyperventilation, and bolus of fluid influences our measures.
Study Type
Enrollment (Actual)
Contacts and Locations
Study Locations
-
-
Please Select
-
Oslo, Please Select, Norway, 0367
- Oslo University Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Healthy subjects who have signed informed consent
Exclusion Criteria:
- Sick subjects at test day
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Correlation between different measures of hemodynamics
Time Frame: September to December
|
Calculated based on a number of hemodynamic measures listed in the protocol
|
September to December
|
Collaborators and Investigators
Study record dates
Study Major Dates
Study Start (ACTUAL)
Primary Completion (ACTUAL)
Study Completion (ACTUAL)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (ACTUAL)
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
- 153368
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- SAP
- ICF
- ANALYTIC_CODE
- CSR
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Hemodynamics
-
Cardinal HealthRecruitingHemodynamicsUnited States
-
Kepler University HospitalCompleted
-
AstesCompleted
-
Cairo UniversityCompleted
-
Finn GustafssonCompleted
-
Peking University Shenzhen HospitalRecruiting
-
Eye & ENT Hospital of Fudan UniversityRecruiting
-
General Hospital of Ningxia Medical UniversityCompleted
-
Ajou University School of MedicineCompleted
-
Rabin Medical CenterCompleted
Clinical Trials on Biosensors
-
Lars WikOslo University Hospital; University of the Basque Country (UPV/EHU); University... and other collaboratorsCompleted
-
Medtronic VascularCompletedCoronary Artery DiseaseKorea, Republic of, Spain, Australia, Hong Kong, United Kingdom, Singapore, Thailand, Belgium, New Zealand, Sweden, France, Switzerland, Netherlands, Italy, Slovakia, Lithuania, Austria, Malaysia, Bulgaria, Ireland, Latvia, Norway, ...
-
University Hospital, LimogesCompleted
-
Region Örebro CountyBiosensors InternationalWithdrawnStable Angina Pectoris | Unstable Angina Pectoris | Myocardial Infacrtion
-
Yonsei UniversityGangwon Cardiovascular Health Research InstituteTerminated
-
Euro CTO ClubNHS Research and Development; Biosensors International; Asahi Intecc Co., Ltd.CompletedCoronary Occlusion | Dyspnea | Chronic Stable AnginaUnited Kingdom, Spain, France, Germany, Italy, Latvia
-
Seoul National University Bundang HospitalKorea University Anam Hospital; Korea University Guro Hospital; Gachon University... and other collaboratorsCompletedMyocardial Ischemia | Coronary Artery DiseaseKorea, Republic of
-
Dr Peter BarlisBiosensors InternationalUnknownCoronary Heart DiseaseAustralia
-
Central Clinical Hospital of the Ministry of Internal...University National Heart HospitalCompleted
-
Catholic University of the Sacred HeartMerck Sharp & Dohme LLCCompleted