Single-center, Double-arm, Prospective Clinical Trial to Compare Visual Performance of Non-diffractive Extended Vision and Neutral Aspheric Monofocal Intraocular Lenses

August 17, 2023 updated by: Seth M Pantanelli, Milton S. Hershey Medical Center

The purpose of this study is to compare the binocular distance, intermediate, and near visual acuity of the Alcon Vivity and Bausch & Lomb enVista IOLs.

We hypothesize that the Alcon Vivity and Bausch & Lomb enVista IOLs will have similar distance, intermediate, and near visual acuity. If the null hypothesis is rejected, then the visual performance of the IOLs may be different.

Study Overview

Detailed Description

Presbyopia correcting intraocular lens (PC-IOL) technology has been available for decades. Lens designs have included refractive (e.g. AMO ReZoom), apodized diffractive (e.g. Alcon Acrysof ReSTOR/PanOptix), accommodating (B&L Crystalens), and extended depth-of-focus (e.g. J&J Symfony) technology. Spectacle independence is significantly higher with PC-IOLs when compared with that of monofocal IOLs.1,2 Despite their clear benefits, PC-IOLs are not without drawbacks. Any IOL that splits light to deliver distinct distance and near foci creates the potential for photic phenomenon, which patients may perceive as glare, haloes, and starbursts.3,4

Pseudoaccommodation is defined as an increased depth-of-focus in an emmetropic eye that does not have the ability to change its refractive power. Spherical aberration, which may come from the cornea or IOL, plays an important role in pseudoaccommodation.5,6 There is a small body of literature that IOLs (e.g. Mini WELL, SIFI, Catalina, Italy) with highly-positive spherical aberration can result in significant pseudoaccommodation and lower unwanted optical phenomena than current multifocal IOLs.7

The Alcon Vivity PC-IOL is a hydrophobic acrylic, non-diffractive, extended depth of focus IOL designed for implantation in the capsular bag following cataract extraction. The single-piece IOL has a 6.0 mm diameter and has a hyper-prolate profile that extends the depth of focus to deliver a broader range of sharp vision, with the glare and halo profile approaching that of a monofocal IOL.8

The Bausch & Lomb enVista MX60E is a posterior chamber hydrophobic acrylic IOL. The single-piece IOL has a 6.0 mm diameter and has a neural aspheric optical profile. This neutral aspheric profile, combined with the cornea's natural positive spherical aberration, may extend the depth of focus relative to other negative aspheric hydrophobic acrylic monofocal IOLs on the market.

To date, there is no existing literature comparing the visual performance and patient reported outcomes of the two above mentioned lens technologies; namely, one that relies on a non-diffractive, hyper-prolate profile and another that relies on the cornea's natural positive spherical aberration to provide pseudoaccommodation.

The FDA Summary of Safety and Effectiveness on the Alcon Vivity IOL compares visual and patient reported outcomes of the Alcon Vivity IOL and the Alcon Acrysof SN60WF. While the Alcon Acrysof SN60WF and Bausch & Lomb enVista lenses are not identical, they are considered similar. The document reported improved intermediate vision with the Alcon Vivity over the SN60WF, and rates of reported visual disturbances were similar between the two devices.

Whereas the Alcon Acrysof SN60WF has a negative aspheric optical profile, the Bausch & Lomb enVista has a neutral aspheric optical profile. Theoretically, the Bausch & Lomb enVista IOL may provide increased intermediate vision compared with the SN60WF.

Study Type

Interventional

Enrollment (Actual)

56

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Pennsylvania
      • Hershey, Pennsylvania, United States, 17033
        • Penn State Hershey Medical Center Eye Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 95 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Male or female, age 18 or older at the time of study enrollment.
  • Visually significant cataract in the study eyes for which phacoemulsification cataract extraction and posterior chamber IOL implantation is indicated.
  • Anticipated to undergo bilateral sequential cataract surgery
  • Projected postoperative CDVA 0.20 logMAR (Snellen 20/32) or better in the study eyes, as determined by an Investigator's medical judgement.
  • Calculated spherical power targeted at emmetropia at distance in the study eyes.
  • Calculated IOL power between +15.0 - +25.0 D, inclusive, in both eyes.
  • Measured against-the-rule astigmatism less than 0.6 D or with-the-rule/oblique astigmatism less than 1.25 D.
  • If wearing rigid gas permeable (RGP) contact lens in the study eye, willingness to discontinue lens wear for ≥ 21 days prior to preoperative biometry.
  • Availability, willingness, and sufficient cognitive awareness to return for study-required visits and comply with examination procedures.
  • Willingness to sign the IRB-approved informed consent form (ICF) for study participation.

Exclusion Criteria:

  • Mature cataract in the study eye that is likely to prolong surgical procedure and/or lead to intraoperative complications prior to attempted IOL implantation.
  • Any visually significant intraocular media opacity other than cataract in the study eye (as determined by the investigator). Such opacities might include corneal scar or vitreous hemorrhage.
  • Abnormal corneal findings in the study eye (e.g. keratoconus, pellucid marginal degeneration, irregular astigmatism).
  • Any anterior segment pathology in the study eye that could significantly affect outcomes (e.g. chronic uveitis, iritis, aniridia, clinically significant corneal dystrophies, poor pupil dilation, etc.)
  • Any condition in the study eye that could affect IOL stability (e.g. pseudoexfoliation, zonular dialysis, evident zonular weakness or dehiscence, etc.).
  • History of severe dry eye in the study eye that, in the judgement of the investigator, would impair the ability to obtain reliable study measurements.
  • History of serious corneal disease (e.g. herpes simplex, herpes zoster keratitis, etc.) in the study eye.
  • History of any clinically significant retinal pathology or ocular diagnosis in the study eye that could, in the investigator's best judgement, alter or limit final post-operative visual prognosis (e.g. diabetic retinopathy, ischemic disease, macular degeneration, retinal detachment, optic neuropathy, amblyopia, strabismus, aniridia, epiretinal membrane, etc.).
  • History of cystoid macular edema in either eye.
  • History of uveitis in either eye.
  • History of intraocular or corneal surgery in the study eye besides laser peripheral iridotomy (LPI), selective laser trabeculoplasty (SLT), or argon laser trabeculoplasty (ALT).
  • Uncontrolled glaucoma in the study eye (per Investigator judgement).
  • Current ocular infection in the study eye.
  • Presence of uncontrolled systemic disease that could increase operative risk (e.g. diabetes mellitus, mental illness, dementia, clinically significant atopic disease, etc.).
  • Planned concomitant ocular procedure during cataract surgery inclusive of glaucoma surgery e.g. MIGS or limbal relaxing incisions.
  • Symptoms that might be consistent with active COVID-19 including fever, chills, cough, shortness of breath or difficulty breathing, fatigue, muscle or body aches.
  • If COVID-19 positive, at least two weeks since last symptoms.
  • Unsuitable for study participation for any other reason, as determined by the Investigator's clinical judgement.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Double

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Extended Vision IOL
Vivity
Vivity IOL implantation following cataract extraction
Active Comparator: Neutral Aspheric Monofocal IOL
enVista [MX60E]
enVista IOL implantation following cataract extraction

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Binocular Intermediate Vision
Time Frame: 3 months
Mean logMAR best-distance corrected visual acuity at intermediate (66 cm) tested in binocular photopic conditions at 3 months.
3 months

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

November 20, 2020

Primary Completion (Actual)

July 26, 2022

Study Completion (Actual)

August 24, 2022

Study Registration Dates

First Submitted

October 11, 2020

First Submitted That Met QC Criteria

October 11, 2020

First Posted (Actual)

October 19, 2020

Study Record Updates

Last Update Posted (Actual)

August 21, 2023

Last Update Submitted That Met QC Criteria

August 17, 2023

Last Verified

August 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • 15524

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Cataract

Clinical Trials on Extended Vision IOL