Optimal Bupivacaine Dose for Initiation of Labor Epidural Techniques

August 2, 2022 updated by: Lawrence Ching Tsen, Brigham and Women's Hospital

A Trial to Determine the Optimal Bupivacaine Dose for Initiation of Labor Epidural Pain Relief

To estimate the dose of bupivacaine required to achieve initial effective comfort in 90% of patients (ED90) via the epidural (DPE or EPL) technique in women undergoing labor.

Study Overview

Status

Completed

Conditions

Intervention / Treatment

Detailed Description

The primary objective of our study is to use a biased coin up-down allocation methodology to estimate the dose of bupivacaine required to achieve initial effective comfort in 90% of patients (ED90) via the epidural (DPE or EPL) technique in women undergoing labor induction or augmentation; we hypothesize that we will be able to determine the ED90 of bupivacaine for each technique with adequate precision to inform the optimal doses.

Study Type

Interventional

Enrollment (Actual)

100

Phase

  • Phase 4

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Massachusetts
      • Boston, Massachusetts, United States, 02115
        • Brigham and Women's Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years to 50 years (Adult)

Accepts Healthy Volunteers

Yes

Genders Eligible for Study

Female

Description

Inclusion Criteria:

  1. Parturient with no major co-morbidities
  2. Singleton, vertex gestation at term (37-42 weeks)
  3. Less than or equal to 5 cm dilation
  4. Desire to receive epidural labor analgesia
  5. Numerical Rating Scale greater or equal to 5 (NRS 0-10, where 0 = no pain, and 10 = worst pain imaginable), at time of epidural labor analgesia request.

Exclusion Criteria:

  1. Current or historical evidence of clinically significant disease or condition, including diseases of pregnancy (i.e preeclampsia, gestational diabetes)
  2. Any contraindication to the administration of an epidural technique
  3. History of hypersensitivity or idiosyncratic reaction to an amide local anesthetic agent
  4. Current or historical evidence of a disease which may result in the risk of a cesarean delivery (i.e. history of uterine rupture). NB: Exception-trial of labor after cesarean delivery (TOLAC) will be eligible.
  5. Evidence of anticipated fetal anomalies

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Triple

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Dural Puncture Epidural Technique
Laboring women receiving the Dural Puncture Epidural (DPE) Technique with dose of Bupivacaine 0.25% diluted to 20 mL with isotonic sterile 0.9% saline. The first subject in the DPE group will receive an initial dose of bupivacaine 25 mg, with an endpoint being the achievement of an NRS < 3 at 30 min. Subsequent patients are administered bupivacaine doses determined by the response of the previous subject, as per the biased coin method. The subsequent up and down interval doses are bupivacaine 2.5 mg (1 mL) increments, with an anticipated dose range from 20 mg to 40 mg.
Local Anesthetic Agent
Other Names:
  • Marcaine
Active Comparator: Epidural Technique
Laboring women receiving the Conventional Epidural Technique (EPL) with dose of Bupivacaine 0.25% diluted to 20 mL with isotonic sterile 0.9% saline. The first subject in the EPL group will receive an initial dose of bupivacaine 25 mg, with an endpoint being the achievement of an NRS < 3 at 30 min. Subsequent patients are administered bupivacaine doses determined by the response of the previous subject, as per the biased coin method. The subsequent up and down interval doses are bupivacaine 2.5 mg (1 mL) increments, with an anticipated dose range from 20 mg to 40 mg.
Local Anesthetic Agent
Other Names:
  • Marcaine

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Verbal Numerical Rating Score (0-10, with higher scores meaning more pain); goal with analgesia is < 3/10
Time Frame: 30 minutes
Pain Score (0=no pain, 10= worst pain imaginable)
30 minutes

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Lawrence Tsen, MD, Associate Professor in Anesthesiology, Harvard Medical School

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

February 25, 2021

Primary Completion (Actual)

March 23, 2022

Study Completion (Actual)

March 23, 2022

Study Registration Dates

First Submitted

March 22, 2021

First Submitted That Met QC Criteria

March 22, 2021

First Posted (Actual)

March 24, 2021

Study Record Updates

Last Update Posted (Actual)

August 4, 2022

Last Update Submitted That Met QC Criteria

August 2, 2022

Last Verified

August 1, 2022

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

Yes

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Analgesia

Clinical Trials on Bupivacaine Hydrochloride

3
Subscribe