- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05134051
Microcirculatory Status After Intravascular Lithotripsy (MARVEL)
Study Overview
Status
Intervention / Treatment
Detailed Description
Patients with stable coronary artery disease or stabilized acute coronary syndromes with severely calcified de novo coronary stenoses with indication of plaque modification technique during PCI.
Due to differences in the mechanism of action, intravascular lithotripsy is likely to cause less distal embolization and microcirculatory dysfunction during plaque preparation. This may also translate into lower periprocedural myocardial infarction rates.
To perform the invasive physiology assessment an intracoronary pressure and temperature sensor-tipped guidewire is used to measure distal coronary pressure and to derive thermodilution curves. For the calculation of IMR three thermodilution curves can be obtained from a hand-held, 3-ml rapid (<0.25s) injection of room temperature saline at baseline and during maximal hyperemia. Mean transit time (Tmn) at baseline and during maximal hyperemia is derived from the thermodilution curves. Simultaneous recordings of mean aortic pressure (guiding catheter, Pa) and mean distal coronary pressure (distal pressure sensor, Pd) is also obtained at baseline and during maximal hyperemia. The IMR is then calculated using the following equation: IMR = PaxTmn[(Pd-Pw)/(Pa-Pw)], where Pw is the coronary wedge pressure. Pw will be measured as the distal coronary pressure (from the distal pressure and temperature sensor) during complete balloon occlusion of the vessel obtained during PCI.
The aim of the present study is to investigate the protective effect of IVL (Shockwave© Medical) on the coronary microcirculatory during PCI in calcific coronary stenosis, compared to RA.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Madrid, Spain, 28040
- Hospital San Carlos
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- ADULT
- OLDER_ADULT
- CHILD
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
Angiographic inclusion criteria
- Severely calcified stenoses
- Vessels with RVD between 2.5 - 4.0 mm
- TIMI flow 3
Exclusion Criteria:
Angiographic exclusion criteria
- Concomitant use of rotational atherectomy
- Severe vessel tortuosity
- Stenosis un-crossable with a balloon/guidewire
- Concomitant conditions
- Contraindication for adenosine administration.
- Hemodynamic or electrical instability.
- Active liver disease or hepatic dysfunction, defined as AST or ALT > 3 times the ULN.
- Severe renal dysfunction, defined as an eGFR <30 mL/min/1.73 m2, unless the patient is in renal support therapy.
Other exclusion criteria
- Unable to provide written informed consent (IC)
- Known pregnancy or breast-feeding at time of inclusion; pre-menopausal women, unless sterilized, must take an effective method of birth control up to 15 weeks after the end of treatment with IP
- Prior myocardial infarction subtended to the PCI target vessel.
- Akinesia or dyskinesia in myocardial segments in the distribution area of the PCI target vessel.
- Severe systolic dysfunction defined as left ventricular ejection fraction < 35%.
- Patent arterial or venous surgical graft supplying the PCI target vessel.
- Previous TIMI flow < 1 before guidewire crossing.
- Patient not eligible for drug-eluting stent treatment.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: DIAGNOSTIC
- Allocation: NA
- Interventional Model: SINGLE_GROUP
- Masking: NONE
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
EXPERIMENTAL: Single arm
single arm intervention with IVL in calcified de novo coronary stenoses with indication of plaque modification technique during PCI
|
IVL is a novel balloon catheter-based device that utilises pulsatile mechanical energy to disrupt calcified lesions.
IVL differs from other types of lithotripsy with respect to depth of penetration.
It is a single-use, sterile, disposable balloon catheter.
The emitters convert electrical energy into transient acoustic circumferential pressure pulses that disrupt both superficial and deep calcium within plaque.
The balloon catheter is connected to the generator, which is programmed to deliver the specified dosage of pulses.
The IVL balloon, sized 1:1 to the reference artery ratio, is inflated low pressure (4 atm) with 10 pulses of ultrasound energy of 10s delivered per balloon.
The procedure is repeated to provide a minimum of 20 pulses in the target lesion, with interval deflation to allow distal perfusion.
Each catheter can emit a max of 80 pulses at a rate of one pulse per second.
If the lesion exceeds the 12mm balloon length, the balloon can be repositioned and the IVL repeated.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Index of Microcirculatory Resistance (IMR) after IVL
Time Frame: through study completion, an average of 1 year
|
through study completion, an average of 1 year
|
Secondary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Post-PCI FFR after IVL
Time Frame: through study completion, an average of 1 year
|
through study completion, an average of 1 year
|
|
Rate of periprocedural myocardial infarction
Time Frame: through study completion, an average of 1 year
|
through study completion, an average of 1 year
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Carlos Collet, Cardiovascular Center OLV Aalst
Study record dates
Study Major Dates
Study Start (ACTUAL)
Primary Completion (ACTUAL)
Study Completion (ACTUAL)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (ACTUAL)
Study Record Updates
Last Update Posted (ACTUAL)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- 2020/066
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.