- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05304026
Optimizing CO2 Injection Technique for EVAR
Optimizing CO2 Injection Technique for Renal Artery Detection in Endovascular Abdominal Aortic Aneurysm Repair
Automated carbon dioxide (CO2) angiography is considered a safe diagnostic alternative to standard iodinated contrast medium (ICM) for endovascular aortic repair (EVAR) of abdominal aortic aneurysm (AAA), especially in patients with preoperative renal function impairment.
Recent literature experiences describe the use of automated CO2 angiography in EVAR.
One of the main issues of CO2 angiography is the inability to detect the origin of the lowest renal artery (proximal neck visualization) that was estimated up to 38%.
In these experiences, the CO2 automated angiography is usually performed by a 5F pigtail catheter placed at renal arteries level.
The aim of the study is to evaluate the efficacy of a new automated CO2 injection technique by a 5F introducer (single hole catheter) positioned at the distal level of the proximal neck in detecting both renal arteries in the first diagnostic and completion angiographies.
Study Overview
Status
Intervention / Treatment
Detailed Description
Endovascular aneurysm repair is currently a wide spread therapeutic option due to a lower 30-day morbidity/mortality compared with open repair (OR), especially in patients with high surgical risk. The routinary EVAR technique requires the use of iodinated contrast medium (ICM) which can cause contrast induced-acute kidney injure (CI-AKI). The incidence of CI-AKI after EVAR is estimated between 2% and 16% although renal insult can also be caused by microembolization, unplanned renal (or polar) artery coverage, renal artery lesion (as dissection) or post-operative inflammatory reaction.
In the past few years, several studies pointed out the importance of reducing the amount of iodinated contrast medium injected and proposed carbon dioxide (CO2) as an alternative to partially or completely replace ICM, especially in patients with preoperative chronic renal impairment.
According with the literature, manual or automatic CO2 injection provides a good quality imaging of both proximal and distal sealing zone in standard EVAR procedures and, combined with fusion imaging, allows to perform juxta and pararenal abdominal aortic aneurysm repair with fenestrated endograft reducing the total amount of ICM required to the procedure.
The most relevant limit to the use of CO2 is the inability to identify the proximal landing zone and the lowest renal artery that occurs in a significant number of cases (38.7%).
This limit could be related to the physical property of CO2 because, differently from ICM, it is a gas that does not completely fill the aortic lumen but it floats in the anterior portion of the aneurysmatic sac and does not allow the detection of renal arteries with a posterior origin.
The automated CO2 injection is commonly performed using a pigtail catheter (5F/65mm length) placed at the renal arteries level.
The primary end point of the study is to identify an alternative and effective method of CO2 injection, using an automatic system through the digital Angiodroid injection system (Angiodroid Srl, San Lazzaro, Bologna) connected to a 5F introducer placed at the distal portion of infra-renal neck that allows the identification of the lowest renal artery.
This is a prospective, single center, observational, case-control study, in which each patient is the control of himself because during the procedure 2 angiographic CO2 techniques (angiography by pig tail vs 5 F introducer) are performed and compared.
All patients underwent a preoperative computed tomography angiography (CTA) within 3 months before the procedure. The images are analyzed using a dedicated software for vessel analysis (3Mensio TM, Vascular Imaging Bilthover, Netherlands) and the AAA volume is calculated using the same software by selecting points of the external aortic wall and internal aortic lumen from the lower renal artery to the aortic bifurcation.
The level of renal arteries and aortic bifurcation are evaluated on preoperative CTA reconstructions and matched with vertebral bone landmarks.
At the beginning of the procedure two CO2 DSA will be performed: the first one through the pigtail placed at the level of renal arteries and the second one through a 5F introducer placed at the end of the proximal sealing zone in order to identify the lowest renal artery and compare the quality of the images obtained.
The same way, at the end of the procedure after the endograft deployment, two CO2 DSA will be performed: the first one through the pigtail catheter placed at the level of renal arteries and the second one through the 5F introducer placed at the level of the contralateral iliac limb.
The investigators prospectively collect clinical and morphological preoperative, intraoperative and postoperative data as shown in the table above.
Clinical characteristics: age years, sex, hypertension (systolic blood pressure ≥140 or/and diastolic ≥90 mmHg, or specific therapy), dyslipidemia (total cholesterol ≥200 mg/dl or low density lipoprotein ≥120 mg/dl or specific therapy), diabetes mellitus (pre-diagnosed in therapy with oral hypoglycemic drugs or with insulin), current smoking, coronary artery disease (defined as a history of angina pectoris, myocardial infarction or coronary revascularization), chronic obstructive pulmonary disease (defined as chronic bronchitis or emphysema), chronic kidney disease (glomerular filtration rate <60 ml/min), dialysis, pre and post-operative creatinine serum, ASA (American Society Anesthesiologic classification), medical therapy (antiplatelet types, anticoagulant therapy, statin therapy, anti-hypertensive medical therapy).
Morphological characteristics: aneurysm diameter, aneurysm volume, aneurysm neck features according to Chaickof classification, iliac axes features according to Chaickof classification, renal arteries number and clock position, hypogastric arteries patency, aortic carrefour diameter.
Intraoperative data: anesthesia (general or spinal), vascular access (surgical or percutaneous), endograft features (bi- or tri-modular, suprarenal fixation, proximal diameter of the endograft, left and right iliac limb diameter, embolization of the aneurysmatic sac, coils number, hypogastric embolization or coverage, other adjunctive maneuvers as iliac axes stenting), type and amount of contrast medium, fluoroscopy time, dose area product (DAP) (fluoroscopy DAP, DSA DAP and total DAP), renal arteries detection at the beginning of the procedure with CO2 DSA from 5F pigtail and 5F introducer, renal and hypogastric arteries and endoleaks detection at the end of the procedure with CO2 DSA from 5F pigtail and 5F introducer (as explained before).
Post-operative data: complications related to CO2 injection rate (nausea, vomit, abdominal pain, hypotension), endoleaks at the discharge, perioperative mortality, 30-days mortality, 30-days medical or surgical complications, 30-days reintervention rate, 30-days renal function.
Study Type
Enrollment (Anticipated)
Contacts and Locations
Study Contact
- Name: Enrico Gallitto, MD, PhD
- Phone Number: +390512143288
- Email: enrico.gallitto@gmail.com
Study Locations
-
-
Emilia Romagna
-
Bologna, Emilia Romagna, Italy, 40138
- Recruiting
- University of Bologna
-
Contact:
- Enrico Gallitto, MD, PhD
- Phone Number: +390512143288
- Email: enrico.gallitto@gmail.com
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Description
Inclusion Criteria:
- Patients with asymptomatic infrarenal abdominal aortic aneurysm admitted to the S. Orsola - Malpighi Hospital for a planned EVAR procedure. All patients underwent a preoperative computed tomography angiography (CTA) with a <2mm slices.
Exclusion Criteria:
- Patients with contraindication for CO2 (cardiac septal defects, pulmonary arteriovenous malformations, pulmonary hypertension, severe emphysema)
- Patients requiring advanced aortic repair (FEVAR, BEVAR)
- Urgent cases
Study Plan
How is the study designed?
Design Details
- Observational Models: Case-Control
- Time Perspectives: Prospective
Cohorts and Interventions
Group / Cohort |
Intervention / Treatment |
|---|---|
|
Population
The group includes all patients undergoing EVAR, each patient is considered as both case and control of himself as the two CO2 injection techniques, through the 5F pigtail and through the 5F introducer, are both used during the procedure.
|
It refers to CO2 digital subtraction angiographies performed at the beginning of the procedure through a 5F pigtail catheter placed at the level of renal arteries to identify the lowest renal artery.
It refers to CO2 digital subtraction angiographies performed at the beginning of the procedure through a 5F introducer placed at the end of the proximal sealing zone to identify the lowest renal artery.
It refers to CO2 digital subtraction angiographies performed at the end of the procedure through a 5F pigtail catheter through the pigtail catheter placed at the level of renal arteries.
It refers to CO2 digital subtraction angiographies performed at the end of the procedure through a 5F introducer placed at the level of the contralateral iliac limb.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Aortic neck detection
Time Frame: At the moment of CO2 injection during the procedure
|
Define the efficacy of the alternative CO2 injection technique in the detection of renal arteries in those cases when the usual technique doesn't succeed.
|
At the moment of CO2 injection during the procedure
|
|
Procedure success
Time Frame: At the moment of CO2 injection during the procedure
|
Define the efficacy of the alternative CO2 injection technique in the detection of renal arteries, hypogastric arteries and endoleaks at the final angiography in those cases when the usual technique doesn't succeed.
|
At the moment of CO2 injection during the procedure
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
CO2 complications
Time Frame: within 30 days from the procedure
|
Evaluate CO2 induced complications rate
|
within 30 days from the procedure
|
|
Mortality
Time Frame: within 30 days from the procedure
|
Evaluate 30-day mortality related to procedure
|
within 30 days from the procedure
|
|
Adverse events
Time Frame: within 30 days from the procedure
|
Assessment of any cardiopulmonary and renal events related to the procedure
|
within 30 days from the procedure
|
|
Rate of early reintervention
Time Frame: within 30 days from the procedure
|
Any re-intervention needed after the procedure and the specific reason
|
within 30 days from the procedure
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Enrico Gallitto, MD, PhD, University of Bologna
Publications and helpful links
General Publications
- Mascoli C, Faggioli G, Gallitto E, Vento V, Pini R, Vacirca A, Indelicato G, Gargiulo M, Stella A. Standardization of a Carbon Dioxide Automated System for Endovascular Aortic Aneurysm Repair. Ann Vasc Surg. 2018 Aug;51:160-169. doi: 10.1016/j.avsg.2018.01.099. Epub 2018 Mar 6.
- Gallitto E, Faggioli G, Vacirca A, Pini R, Mascoli C, Fenelli C, Logiacco A, Abualhin M, Gargiulo M. The benefit of combined carbon dioxide automated angiography and fusion imaging in preserving perioperative renal function in fenestrated endografting. J Vasc Surg. 2020 Dec;72(6):1906-1916. doi: 10.1016/j.jvs.2020.02.051. Epub 2020 Apr 8.
- Mascoli C, Faggioli G, Gallitto E, Vento V, Indelicato G, Pini R, Vacirca A, Stella A, Gargiulo M. The Assessment of Carbon Dioxide Automated Angiography in Type II Endoleaks Detection: Comparison with Contrast-Enhanced Ultrasound. Contrast Media Mol Imaging. 2018 Mar 26;2018:7647165. doi: 10.1155/2018/7647165. eCollection 2018.
- Vacirca A, Faggioli G, Mascoli C, Gallitto E, Pini R, Spath P, Logiacco A, Palermo S, Gargiulo M. CO2 Automated Angiography in Endovascular Aortic Repair Preserves Renal Function to a Greater Extent Compared with Iodinated Contrast Medium. Analysis of Technical and Anatomical Details. Ann Vasc Surg. 2022 Apr;81:79-88. doi: 10.1016/j.avsg.2021.10.039. Epub 2021 Nov 14.
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Anticipated)
Study Completion (Anticipated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
- CO2 IT
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Abdominal Aortic Aneurysm
-
Karolinska University HospitalKarolinska Institutet; Swedish Heart Lung FoundationActive, not recruitingAortic Aneurysm | Aortic Aneurysm Abdominal | Abdominal AneurysmSweden
-
Assistance Publique - Hôpitaux de ParisUnknownSmall Abdominal Aortic Aneurysm | Abdominal Aortic Aneurysm,France
-
Karolinska University HospitalEnrolling by invitationAneurysm | Aortic Aneurysm | Abdominal Aortic Aneurysm, Ruptured | Aneurysm Abdominal | Abdominal Aortic Aneurysm Without RuptureSweden
-
EndologixActive, not recruiting1 Paravisceral Abdominal Aortic Aneurysm | 2 Juxtarenal Abdominal Aortic Aneurysm | 3 Pararenal Abdominal Aortic Aneurysm | 4 Complex Abdominal Aortic AneurysmsUnited States
-
University of TwenteNot yet recruitingAbdominal Aortic Aneurysm | Endovascular Abdominal Aortic Aneurysm Repair | Fenestrated Endovascular Aortic RepairNetherlands
-
Angiolutions GmbHRecruitingAneurysm, Abdominal AorticUzbekistan
-
Rijnstate HospitalCompletedAAA - Abdominal Aortic AneurysmNetherlands
-
University Hospital of LimerickCompleted
-
Medtronic CardiovascularCompletedAbdominal Aortic Aneurysms (AAA)United States
-
Vascutek Ltd.TerminatedAbdominal Aortic Aneurysms (AAA)United Kingdom, Netherlands, Switzerland, Spain, Germany, Belgium, Sweden, Canada, France, Italy, Austria, Monaco
Clinical Trials on Technique 1
-
Johnson & Johnson Surgical Vision, Inc.Completed
-
Poitiers University HospitalRecruiting
-
Sheffield Teaching Hospitals NHS Foundation TrustDentsply InternationalCompleted
-
KaVo KerrUnknownRoot Canal InfectionUnited States
-
Mansoura UniversityCompletedPilonidal DiseaseEgypt
-
Uskudar UniversityRecruitingNeck Pain | Non-specific Neck PainTurkey (Türkiye)
-
Lydia NabilCompletedAlveolar Ridge EnlargementEgypt
-
Foundation University IslamabadEnrolling by invitationPost-Operative HypersensitivityPakistan
-
Fundacion REVIVA, Red de VIH del Valle del CaucaViiV Healthcare; Centro de Investigación en. Enfermedades Infecciosas, MexicoCompleted
-
Hospices Civils de LyonCompletedPrimary Motor Cortex | Motor CortexFrance