- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT05461677
Walking With the SAIRE Smart Walker (SAIRE)
Study Overview
Status
Intervention / Treatment
Detailed Description
This study is an experimental single group study investigating the effect of walking with a smart walker compared to walking with a standard walker or no walking aid in persons who suffer from gait difficulties. Participants will perform one session of walking in three different conditions, (1) walking with the SAIRE smart walker, (2) walking with a standard walker and (3) if the participants are able to walk without the use of an assistive device, walking without a walker. During this session, gait parameters will be compared between the three conditions.
Experimental session: During the experimental session, participants will walk along the 10-meter walkway (5 times for every condition) After every 5 trials, a rest period of minimum 5 minutes will be held to avoid fatigue. Three different walking conditions will be measured: (1) walking with the SAIRE smart walker, (2) walking with a standard walker and if possible (3) walking with no walking aid. Each walking condition will be measured five consecutive times in a randomized order. The order of the conditions will be randomized using closed envelopes containing notes that say what order of conditions will be used. This randomization is done to avoid fatigue effects that might occur when a strict order is used.
Before the start of the experimental session, participants will practice using the SAIRE smart walker for maximum 10 minutes to familiarize with the feedback given by the walker. After this familiarization session, the surface electrodes and reflective markers will be placed on the participants and the experimental session will start.
Analysis: This study will investigate the difference in gait biomechanics of adults with gait difficulties while using different walking aids.
Descriptive statistics of the baseline characteristics of all participants will be performed. The effect of gait with a smart walker on spatiotemporal gait parameters, kinematics and muscle activity will be compared to gait with a standard 2-wheeled walker and gait without a walking aid. Data will be visualized using LO(W)ESS smoothing (locally weighted scatterplot smoothing) to explore the effect (per condition and outcome). Values will be compared between conditions in a one-way repeated measures analysis of variance. For the analysis of the USE questionnaire, percentage distribution of every item and mean scores for every subscale will be calculated using Microsoft Excel (Microsoft, Washington, DC).
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Brussels Hoofdstedelijk Gewest
-
Jette, Brussels Hoofdstedelijk Gewest, Belgium, 1090
- Brubotics Rehabilitation Research Center
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Ability to walk along a 10-meter walkway multiple times over a period of 120 minutes
- Ambulation with any sort of assistive device (e.g. cane, crutches, walker, etc.)
- Sufficient arm/hand function to walk with a walker
- Capable of understanding and carrying out instructions
- Capable of giving informed consent
Exclusion Criteria:
- Presence of cognitive impairement (MoCA score <23)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: SAIRE smart walker
The investigational device used in this clinical investigation is called the SAIRE smart walker. This first prototype version is equipped with a depth camera and two cheaper cameras. The depth camera is used to acquire high-quality data to train artificial intelligence (AI) models which then can run on the cheaper camera modules. Additionally, two ultrasonic sensors are applied to estimate the distance. A touch monitor is used to provide audiovisual feedback and display the user interface. Two LED strips are also attached to the walker to provide additional visual feedback to the patient. The SAIRE smart walker gives feedback to the patient in terms of cadence using a metronome, and foot placement using the LED strips and the video stream presented on the monitor. Additionally, the walker will give information about step length and step width through AI-models. |
Participants will walk along the 10-meter walkway 5 times using the SAIRE smart walker
|
|
Active Comparator: Standard walker
The comparator device consist of a standard 4-wheeled walker
|
Participants will walk along the 10-meter walkway 5 times using a standard 4-wheeled walker
|
|
Active Comparator: No walking aid
|
Participants will walk along the 10-meter walkway 5 times without using a walking aid
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
3D kinematic measurements of the lower limb
Time Frame: At the end of the experimental session, Day 1
|
Kinematic data (i.e., movement amplitudes of the bilateral hip, knee and ankle joint) of the lower limbs during walking will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Walking speed
Time Frame: At the end of the experimental session, Day 1
|
Walking speed will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Cadence
Time Frame: At the end of the experimental session, Day 1
|
Cadence will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Step length
Time Frame: At the end of the experimental session, Day 1
|
Step length will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Step time
Time Frame: At the end of the experimental session, Day 1
|
Step time will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Swing time of the lower limbs
Time Frame: At the end of the experimental session, Day 1
|
Swing time of the lower limbs during walking will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Stance time
Time Frame: At the end of the experimental session, Day 1
|
Stance time of the lower limbs during walking will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Single limb support period
Time Frame: At the end of the experimental session, Day 1
|
Single limb support period will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Double limb support period
Time Frame: At the end of the experimental session, Day 1
|
Double limb support period will be recorded continuously with the use of a 14-camera Vicon Vero 1.3 system at 100 Hz.
|
At the end of the experimental session, Day 1
|
|
Electromyography
Time Frame: At the end of the experimental session, Day 1
|
Muscle activity of the lower limb muscles (bilateral: M. rectus femoris, M. vastus lateralis, M. biceps femoris, M. tibialis anterior, M. gastrocnemius medialis) will be recorded continuously during treadmill walking with the use of surface electrodes.
Signals will be recorded with the wireless Cometa Wave Plus EMG system (16 channels).
|
At the end of the experimental session, Day 1
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
User experience with a modified version of the USE questionnaire
Time Frame: At the end of the experimental session, Day 1
|
User experience will be assessed using a translated version of the self-administered Usefulness, Satisfaction and Ease of use (USE) questionnaire.
This scale ranges from 30 to 210, with a higher score translating to higher satisfaction.
Additionally, open questions were added to the questionnaire to uncover possible barriers and facilitators in the use of the smart walker.
|
At the end of the experimental session, Day 1
|
Collaborators and Investigators
Sponsor
Investigators
- Principal Investigator: Eva Swinnen, Prof. Ph.D, Vrije Universiteit Brussel
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- SAIRE Smart Walker
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Gait Disorders, Neurologic
-
Rehaklinik Zihlschlacht AGRecruiting
-
University Health Network, TorontoRecruiting
-
NUMEN FoundationUniversidad Europea de MadridNot yet recruiting
-
Superior UniversityActive, not recruitingEfficacy of VR Based Sword Fighting Exercises to Improve Upper Body Movements in Hemiplegic PatientsHemiplegic GaitPakistan
-
University of PittsburghCompleted
-
Beni-Suef UniversityCompleted
-
Medical University of ViennaCompletedGait, Hemiplegic
-
Umm Al-Qura UniversityCompleted
-
University of PittsburghNational Institute on Aging (NIA)Withdrawn
-
Istituto Ortopedico GaleazziCompleted
Clinical Trials on SAIRE smart walker
-
MaineHealthWithdrawn
-
Cairo UniversityCompleted
-
Necmettin Erbakan UniversityCompleted
-
Mayo ClinicCompletedParkinson's Disease | ParkinsonismUnited States
-
Barron Associates, Inc.Eunice Kennedy Shriver National Institute of Child Health and Human Development... and other collaboratorsCompleted
-
Assiut UniversityUnknown
-
Saint Joseph Mercy Health SystemTerminatedMobility LimitationsUnited States
-
Sheffield Children's NHS Foundation TrustCompleted
-
Hadassah Medical OrganizationCompletedTo Evaluate Effectiveness of the Gait Trainer in Increasing the Functionality and Spatiotemporal Parameters of Gait of 4 Patients.Israel
-
Royal Brompton & Harefield NHS Foundation TrustCompletedLung Diseases, Obstructive | Pulmonary Disease, Chronic Obstructive | Bronchitis, ChronicUnited Kingdom