An Evaluation of End-Expiratory Lung Volume and Pulmonary Mechanics With Different PEEP Levels in Mechanical Ventilation in ARDS Patients

August 8, 2023 updated by: Selvinaz Yüksel Tanrıverdi, Pamukkale University

ARDS management is quite complex, and mortality is high. PEEP titration is very important in mechanical ventilation. However, the most appropriate approach for PEEP titration has yet to be determined. Currently, the emphasis is on focused PEEP implementation. The present study aimed to evaluate the volume gain at different PEEP levels over the pressure-volume curve, the changes in EELV measured by the modified multiple nitrogen wash-out/wash-in technique, and the compliance with respiratory mechanics.

14 adult ARDS patients undergoing invasive mechanical ventilation were included in the study. According to the Berlin Criteria, There were two mild, seven moderates, and five severe ARDS patients. FRC and EELV with decreased PEEP titration estimates (5 cmH2O) were measured by the multiple nitrogen wash-out/washin technique. Gain and compliance values were measured over the dynamic pressure-volume curves created by the intracheal pressure sensor.

Study Overview

Status

Completed

Conditions

Detailed Description

The present study was conducted in the Anesthesiology and Reanimation Intensive Care Units of Pamukkale University Hospital with the approval of Pamukkale University Non-Interventional Clinical Research Ethics Committee dated 13.07.2021 and 13th board meeting numbered 60116787-020/83538. Between August 2021 and August 2022, 17 patients were included over 18 years of age who met the Berlin criteria and were diagnosed with ARDS sedated, intubated, and mechanically ventilated. Informed written consent was obtained from the relatives.

Patients included in the study were connected to a CARESCAPE R860 (GE Healthcare) mechanical ventilator. Rocuronium bromide was administered intravenously to eliminate the spontaneous respiratory effort and opioids for sedation. Tidal volume was adjusted as 6 ml/kg according to the estimated body weight; the respiratory rate was adjusted to ensure normocarbia in blood gas analysis; FiO2 was adjusted as PaO2 55 to 80 mmHg; end-inspiratory pause was adjusted to 20%, and inspiratory/expiratory ratio was adjusted as 1:2.

The ECOV-X (GE Healthcare) module was attached to the ventilator for gas measurements and allowed to warm up. A spirometer kit was inserted between the Y-piece in the ventilator circuit and the bacterial/viral filter with heat and moisture-retaining properties. An intratracheal pressure sensor was inserted to measure pressure levels independent of circuit and tube resistance and to evaluate them on the SpiroDynamics (GE Healthcare) application. EELV was measured with the ECOV-X (GE Healthcare) module using a modified NMBW technique with the change in FiO2. EELV was calculated using VO2 (oxygen consumption) and VCO2 (carbon dioxide production). After all the connections were completed, the VO2 and VCO2 values of the patients were measured. The PEEP titration procedure called Lung INview (GE Healthcare) was initiated in patients whose values stabilized within 30 min. Before the measurement, a recruitment maneuver was performed for 30-40 s at a PEEP level of 20 cmH2O. At four different PEEP levels of 15, 10, 5, and 0 cmH2O, a decreasing PEEP trial was performed, and the measurement results were recorded.

For the same PEEP levels, the shunt fraction decreases when a decreasing PEEP maneuver is used instead of an increasing PEEP maneuver. This suggests that the relationship between optimal PEEP and maximum compliance may be more accurate. Therefore, decreasing PEEP trials was preferred as the study protocol.

The measurement time at each PEEP level was chosen as 10 minutes. At the end of the measurement, static compliance was measured by applying an end-inspiratory pause. Tidal volume, peak, and driving pressure were recorded at each step. Respiratory system elastance was calculated using the equation by Henderson et al.(respiratory system elastance = driving pressure/tidal volume). The static strain was calculated using the equation using the tidal volume at the relevant PEEP value (static strain =VPEEP/FRC). The pressure-volume curve generated by the intratracheal pressure sensor at each PEEP level was evaluated using the SpiroDynamics application. A dynamic compliance curve was generated during the analysis, and volume changes in this curve were determined at each PEEP level. The difference in EELV at two different PEEP levels during a descending PEEP trial was calculated as ∆EELV, and the difference between ∆EELV and the volume derived from the pressure-volume curve was calculated as "volume gain" (gain = ∆EELV - volume derived from the curve). The estimated lung volume recovered was calculated using the formula ∆EELV - (∆PEEP x Compliance PEEPlow) and compared with the volume gain. The efficiency of the volume gains concept as an indicator of the volume gained by alveolar recruitment and its role in personalized PEEP titration was evaluated.

Study Type

Interventional

Enrollment (Actual)

14

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Denizli, Turkey
        • Pamukkale University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • Patients diagnosed with ARDS according to the Berlin criteria
  • Berlin definition criteria: (1) presence of acute hypoxemic respiratory failure, (2) onset within 7 days of insult, or or new (within 7 days) or worsening respiratory symptoms; (3) bilateral opacities on chest x-ray or CT not fully explained by effusions, lobar or lung collapse, or nodules; and (4) cardiac failure not primary cause of acute respiratory failure.

Exclusion Criteria:

  • Patients with severe cardiovascular instability (Mean arterial pressure <60 mmHg , Pulse <45 or >150), Patients with pneumothorax, Patients who have undergone pneumonectomy operation, Patients with Lung Transplantation, Patients with thoracic deformity, ARDS patients with cor pulmonale

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Other: ARDS patient
14 patients with ARDS were included in the study. It was planned as a single group.
Before the measurement, a recruitment maneuver was performed for 30-40 s at a PEEP level of 20 cmH2O. At four different PEEP levels of 15, 10, 5, and 0 cmH2O, a decreasing PEEP trial was performed, and the measurement results were recorded.The measurement time at each PEEP level was chosen as 10 minutes. At the end of the measurement, static compliance was measured by applying an end-inspiratory pause. Respiratory system elastance,static strain volume gain was calculated.The estimated lung volume recovered was calculated using the formula ∆EELV - (∆PEEP x Compliance PEEPlow) and compared with the volume gain.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Does volume gain indicate recruited lung volume?
Time Frame: Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.]
A dynamic compliance curve was generated during the analysis, and volume changes in this curve were determined at each PEEP level. The difference in EELV at two different PEEP levels during a descending PEEP trial was calculated as ∆EELV, and the difference between ∆EELV and the volume derived from the pressure-volume curve was calculated as "volume gain" (gain = ∆EELV - volume derived from the curve). The estimated lung volume recovered was calculated using the formula ∆EELV - (∆PEEP x Compliance PEEPlow) and compared with the volume gain.
Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.]

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Static compliance correlation with volume gain.
Time Frame: Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
After measuring the volume gain, its correlation with static compliance was examined. The measurement time at each PEEP level was chosen as 10 minutes. At the end of the measurement, static compliance was measured by applying an end-inspiratory pause
Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
Calculation of respiratory system elastance and its correlation with volume gain.
Time Frame: Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
Respiratory system elastance was calculated using the equation (respiratory system elastance = driving pressure/tidal volume).
Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
Examination of the relationship between static strain and volume gain.
Time Frame: Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
Static strain; calculated by the ratio of tidal volume to FRC at the relevant PEEP level.
Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
Investigation of the correlation between driving pressure and volume gain
Time Frame: Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.
During the measurements, volume gain and driving pressure at different PEEP levels were recorded and their correlations were examined.
Patients were ventilated for 10 minutes at each PEEP level.Measurement was taken after 10 minutes.

Other Outcome Measures

Outcome Measure
Measure Description
Time Frame
Hemodynamic parameters of patient with ARDS were measured during different PEEP measurement.
Time Frame: Measurements were taken after 10 minutes of ventilating at the PEEP level.
Systolic blood pressure, diastolic blood pressure and heart rate, peripheral oxygen saturation at different PEEP levels were recorded.
Measurements were taken after 10 minutes of ventilating at the PEEP level.
Arterial blood gas analysis
Time Frame: Measurements were taken after 10 minutes of ventilating at the PEEP level.
At all PEEP levels, pH, PaO2 (mmHg), PaCO2 (mmHg), SaO2 (%) were measured in arterial blood gas.
Measurements were taken after 10 minutes of ventilating at the PEEP level.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

August 2, 2021

Primary Completion (Actual)

August 26, 2021

Study Completion (Actual)

August 26, 2021

Study Registration Dates

First Submitted

July 31, 2023

First Submitted That Met QC Criteria

August 8, 2023

First Posted (Actual)

August 15, 2023

Study Record Updates

Last Update Posted (Actual)

August 15, 2023

Last Update Submitted That Met QC Criteria

August 8, 2023

Last Verified

August 1, 2023

More Information

Terms related to this study

Other Study ID Numbers

  • PamukkaleUSyuksel-001

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.