Comparison of Acute Effects of Traditional and Drop Set Training on Fatigue and Proprioception in Bodybuilding Athletes

November 12, 2024 updated by: Nihat Sarıalioğlu, Giresun University

Comparison of Acute Effects of Traditional Set and Drop Set Training Methods on Fatigue Levels and Proprioceptive Sensory Mechanism in Bodybuilding Athletes

To compare the acute effects of traditional and drop set training methods on fatigue levels and proprioceptive sensory mechanisms in bodybuilding athletes.

Study Overview

Detailed Description

A total of 28 male bodybuilding athletes with an average age of 25.53 years from Giresun and Ordu provinces participated in the study voluntarily. The participants were randomly divided into two groups as traditional training group (GS) (n=14) and drop set training group (DS) (n=14). Borg CR10 Scale and myotonometric measurements (Myoton Pro muscle palpation device) were used to assess fatigue. Myotonometric measurements were performed on the pectoralis major, triceps brachii and deltoideus muscles. Proprioception characteristics were evaluated in four parameters: shoulder flexion, shoulder abduction, elbow flexion and wrist flexion using laser cursor-assisted angle repetition test.

After the application, fatigue levels in pectoralis major, triceps brachii, Borg CR10 parameters and proprioception errors in shoulder flexion, elbow flexion, wrist flexion parameters were significantly higher in the traditional set group compared to the drop set group.

Study Type

Interventional

Enrollment (Actual)

24

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Centre
      • Gi̇resun, Centre, Turkey, 28200
        • Giresun University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult

Accepts Healthy Volunteers

Yes

Description

Inclusion Criteria:

  • -Being male.
  • Being between the ages of 20-30.
  • To have been doing bodybuilding for at least the last five years.

Exclusion Criteria:

  • -Having undergone a serious surgical operation within the last year,
  • Having used a performance enhancing product that affects the neuromuscular mechanism within the last year,
  • In addition, individuals who did not meet the inclusion criteria were excluded from the study.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Basic Science
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Traditional set training
Traditional set method and drop set method are widely used training methods in bodybuilding. Studies have shown that these methods have similar effects on muscle hypertrophy, increasing lean body mass and other metabolic variables when applied in equal volumes. However, there is no comparative study on the effects of these methods on fatigue and proprioceptive mechanism. In this context, it is thought that it is important to reveal the effects of traditional and drop set training methods on these two variables in order to take necessary measures to protect athlete health and improve athlete performance.
Laser cursor-assisted angle repetition test was used for proprioception assessment. A coordinate plane with different movement angles was fixed on a wall and the person was positioned 1 meter from this wall. The laser pointer was fixed on the person's arm for shoulder proprioception measurement, 5 cm above the elbow to avoid being affected by other joints, 5 cm above the person's wrist for elbow joint proprioception and fixed on the person's second metatarsal bone for wrist proprioception.
Myoton PRO® (Myoton AS, Tallinn, Estonia) muscle palpation device was used to assess fatigue, and the dynamic stiffness parameter was taken as the basis. The stiffness value is calculated as the maximum acceleration (N/m) of oscillation and deformation in the tissue sensed by the transducer (Chen et al., 2017). The increase in muscle dynamic stiffness has been associated with fatigue level (Klich et al., 2019; Shitova et al., 2020; Wang, 2017). Before the measurement, the athletes' pectoralis major, deltoideus and triceps brachii muscle reference points were determined and marked, and measurements were taken over these points. The athletes were asked to keep their muscles relaxed throughout the measurement in order not to affect the tissue stiffness and the application was performed at room temperature.
Active Comparator: Drop set training
Traditional set method and drop set method are widely used training methods in bodybuilding. Studies have shown that these methods have similar effects on muscle hypertrophy, increasing lean body mass and other metabolic variables when applied in equal volumes. However, there is no comparative study on the effects of these methods on fatigue and proprioceptive mechanism. In this context, it is thought that it is important to reveal the effects of traditional and drop set training methods on these two variables in order to take necessary measures to protect athlete health and improve athlete performance.
Laser cursor-assisted angle repetition test was used for proprioception assessment. A coordinate plane with different movement angles was fixed on a wall and the person was positioned 1 meter from this wall. The laser pointer was fixed on the person's arm for shoulder proprioception measurement, 5 cm above the elbow to avoid being affected by other joints, 5 cm above the person's wrist for elbow joint proprioception and fixed on the person's second metatarsal bone for wrist proprioception.
Myoton PRO® (Myoton AS, Tallinn, Estonia) muscle palpation device was used to assess fatigue, and the dynamic stiffness parameter was taken as the basis. The stiffness value is calculated as the maximum acceleration (N/m) of oscillation and deformation in the tissue sensed by the transducer (Chen et al., 2017). The increase in muscle dynamic stiffness has been associated with fatigue level (Klich et al., 2019; Shitova et al., 2020; Wang, 2017). Before the measurement, the athletes' pectoralis major, deltoideus and triceps brachii muscle reference points were determined and marked, and measurements were taken over these points. The athletes were asked to keep their muscles relaxed throughout the measurement in order not to affect the tissue stiffness and the application was performed at room temperature.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Assessment of Demographic and Physical Characteristics
Time Frame: 1 day
A personal information form was used to obtain demographic information. The height measurements of the participants were made with a wall-mounted holtain stadiometer and body weight measurements were made with a Tanita MC-580 body analyser. BMI was calculated by dividing body weight by the square of height (kg/m2).
1 day
Assessment of Proprioception
Time Frame: 1 day

Laser cursor-assisted angle repetition test was used for proprioception assessment. A coordinate plane with different movement angles was fixed on a wall and the person was positioned 1 meter from this wall. In the next step, the person's eyes were closed to prevent visual control and was asked to repeat the same joint position 3 times. The coordinate point where the individual brought the arm was marked on the coordinate plane and this process was repeated 3 times for shoulder flexion and abduction. The deviations at the given angles were measured on the horizontal (X) and vertical (Y) coordinate axes on the coordinate plane, the amount of linear deviation from the target was calculated using the Pythagorean theorem (√(x^2+y^2 )), and the arithmetic mean of the 3 deviations was recorded.

Proprioception level= [(√(x^2+y^2 ))+(√(x^2+y^2 ))+(√(x^2+y^2 ))]/3

1 day
Assessment of Fatigue
Time Frame: 1 day
Myoton PRO® (Myoton AS, Tallinn, Estonia) muscle palpation device was used to assess fatigue, and the dynamic stiffness parameter was taken as the basis. The stiffness value is calculated as the maximum acceleration (N/m) of oscillation and deformation in the tissue sensed by the transducer. The increase in muscle dynamic stiffness has been associated with fatigue level. Before the measurement, the athletes' pectoralis major, deltoideus and triceps brachii muscle reference points were determined and marked, and measurements were taken over these points. The athletes were asked to keep their muscles relaxed throughout the measurement in order not to affect the tissue stiffness and the application was performed at room temperature. All measurements were taken with the participants lying on the stretcher and the device was kept upright to minimise the effect of gravity on tissue properties, with three strokes on the reference points of the muscles.
1 day

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

December 20, 2023

Primary Completion (Actual)

June 26, 2024

Study Completion (Actual)

July 10, 2024

Study Registration Dates

First Submitted

November 11, 2024

First Submitted That Met QC Criteria

November 12, 2024

First Posted (Estimated)

November 14, 2024

Study Record Updates

Last Update Posted (Estimated)

November 14, 2024

Last Update Submitted That Met QC Criteria

November 12, 2024

Last Verified

November 1, 2024

More Information

Terms related to this study

Additional Relevant MeSH Terms

Other Study ID Numbers

  • GRU-SBF-NS-02

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

I don't want my data to be shared.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Proprioception

Clinical Trials on Proprioception Measurements

Subscribe