- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06959576
- Original Trial
Trueness and Dimensional Deviation of 3D Printed Nanocomposite Maxillary Denture Base Resin (In Vivo Study) (dimensions)
Microbial and Laboratory Study of 3D-Printed Reinforced Acrylic Denture
Purpose: To evaluate the effect of adding nano ZrO2 and nano TiO2 nanoparticles on trueness and dimensional deviation of maxillary 3D printed denture base resin on completely edentulous patients.
Materials and Methods: This study was carried out on 24 completely edentulous patients. The patients were divided randomly into three equal groups; Group I: Patients received 3D printed maxillary complete denture without additives, Group II: Patients received 3D printed maxillary complete denture reinforced by Nano ZrO2 (0.4%) by Wt and Group III: Patients received 3D printed maxillary complete denture reinforced by Nano TiO2 (0.4%) by Wt. Trueness was evaluated by scanning the denture using an extraoral scanner after the printing process, before insertion. Dimensional deviation was evaluated by scanning the denture using an extraoral scanner at the time of insertion and after 6 months, 12 months, and 18 months. The trueness and dimensional deviation values were analyzed using repeated measure ANOVA, followed by multiple comparison Turkey test.
Study Overview
Detailed Description
- Primary and final impressions of the maxillary and mandibular arches were taken for each patient following basic prosthetic principles.
- Maxillary and mandibular record blocks were made on the master casts and adjusted in the oral cavity of the patients in a normal manner to ensure an acceptable vertical dimension at occlusion and a freeway space of 2-4 mm. The centric relationship was recorded via the static method.
- An extra-oral scanner was used for scanning master casts (upper and lower), then occlusion blocks on the master cast were scanned after spraying with the scanner spray.
- Master casts and jaw relation records. Standard tessellation language (STL) files were sent to the software platform (Exocad). The software enabled virtually simultaneous mounting and alignment.
- Virtual design of the upper and lower bases and virtual setting of the upper and lower teeth were performed.
- The virtual denture STL file was exported to the LCD printer, which prints the denture base and teeth (trial base) as one unit.
- The try-in step was performed via the trial denture base to check for occlusion, esthetics, and denture border extension.
If any modification was performed on teeth using articulating paper or in the denture base using pressure-indicating paste, the trial denture bases were scanned by an extraoral scanner. The STL file was then sent again to the software for correction of the design, and then sent to the 3D printer software.
- Before printing, each file was checked for support adequacy, the printing orientation was 45 degrees, the thickness of the printed layer was 50 microns, and the printing time was 4 hours and 7 seconds for each denture15
- The denture base and the teeth were printed separately via a 3D printer.16
- For Group Ι, Pink denture base resin was used without nanoparticles for printing the denture bases. However, for Group II, Pink denture base resin reinforced by nanoparticles (ZrO2) (0.4%) by weight was used for printing the denture bases.
- Additionally, for Group III, pink denture base resin reinforced with nanoparticles (TiO2) (0.4%) by weight was used for printing the denture bases.
- For printing the teeth, white tooth resin was used for all groups.
- To remove any residual monomers after printing, the denture bases and teeth were placed in isopropyl alcohol for five minutes.
- Finally, resin was used to attach teeth to recessed pockets in the denture bases, after which the dentures were placed in the postcuring unit.
- Eventually, the dentures were finished, and the teeth were coated with resin glaze to protect and polish areas of posterior pits and fissures and interproximal surfaces from staining or discoloration.
- The dentures were inserted into the patient's mouth and checked for any necessary adjustments, and every patient was given the same post-insertion instructions for home care and follow-up evaluation, and a regular oral and denture hygiene protocol.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Tanta, Egypt
- Faculty of dentistry Tanta university Egypt
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
All patients participating in this study were selected according to the following criteria:
- Completely edentulous patients with good local and systemic health.
- With an age range of 50 to 70 years old.
- Have adequate interarch space and class Ⅰ angle classification.
- Have good neuromuscular control. Patient exclusion criteria
- Any disease that may affect denture construction
- Oral parafunctional habits.
- Temporomandibular disorders
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Screening
- Allocation: N/A
- Interventional Model: Sequential Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: Nanoparticles
Nanoparticles improve the quality of 3D-printed denture base resin
|
Nanoparticles improve the dimensional stability of 3D printed denture base resin, so preventing instability of the denture over time
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Trueness of 3D printing
Time Frame: After printing 0 days
|
Scanning of the maxillary denture bases was done using the extraoral scanner.
|
After printing 0 days
|
|
Dimensional deviation of maxillary 3D printed denture base resin
Time Frame: 18 months
|
Evaluation was carried out during the time of insertion, after 6,12and 18 months.
|
18 months
|
Collaborators and Investigators
Sponsor
Investigators
- Study Director: Houda Amin Rashad, prof, Tanta University
- Study Director: Eman Mohamed Shakal, prof, Tanta University
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Estimated)
Study Record Updates
Last Update Posted (Estimated)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- RP 2#23 1
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Denture Hyperplasia
-
Istanbul UniversityRecruitingDenture, Partial, Removable | Edentulism | Denture, CompleteTurkey
-
The University of Hong KongCompletedDenture | Cetylpyridinium Chloride | Removable Partial Denture | Denture Cleansers
-
University of Sao PauloNot yet recruiting
-
Ibrahim Mohamed Ali Ibrahim Abd ElrahmanActive, not recruitingComplete DentureEgypt
-
Procter and GambleCompleted
-
Hiroko NagaokaTerminatedCrowns | DentureUnited States
-
GlaxoSmithKlineCompleted
-
University of FloridaCompletedDenture Stomatitis | Wear of Denture TeethUnited States
-
HALEONRecruitingDenture RetentionUnited States
-
GlaxoSmithKlineWithdrawnDenture RetentionUnited States
Clinical Trials on nanoparticles
-
Second Affiliated Hospital of Xi'an Jiaotong UniversityRecruitingPapillary Thyroid CancerChina
-
Centre Hospitalier Universitaire de Saint EtienneSAINBIOSECompleted
-
The First Affiliated Hospital with Nanjing Medical...Chia Tai Tianqing Pharmaceutical Group Co., Ltd.RecruitingCoronary Artery CalcificationChina
-
October 6 UniversityCompletedPeriodontitis (Stage 3)Egypt
-
Peking University Cancer Hospital & InstituteCompleted
-
Assiut UniversityNot yet recruitingUrinary Tract Infections (UTIs) | Catheter-Associated Urinary Tract Infections (CAUTIs) | Biofilm Formation by Uropathogenic Escherichia Coli (UPEC)Egypt
-
Universidad Autonoma de San Luis PotosíUnknown
-
Al-Azhar UniversityRecruitingOrthodontic Tooth Movement | Class I Malocclusion | Maxillary PrognathismEgypt
-
Faculty of Dental Medicine for GirlsAl-Azhar UniversityCompletedTeeth Sensitivity | Treated Dentin SurfacesEgypt
-
Peking UniversityUnknownAdvanced Gastric CancerChina