An Evaluation of the Omnipod® M System in Adults With Type 2 Diabetes

April 29, 2026 updated by: Insulet Corporation
This is a single arm feasibility study to evaluate the Omnipod M System in adults with Type 2 Diabetes with the aim to enroll to 40 participants aged 18-75 years with type 2 diabetes to have a minimum of 20 participants initiate the use of Omnipod M System and the goal of 16 participants completing the 6-week treatment period.

Study Overview

Status

Completed

Intervention / Treatment

Study Type

Interventional

Enrollment (Actual)

40

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Massachusetts
      • Boston, Massachusetts, United States, 02215
        • Joslin Diabetes
      • Waltham, Massachusetts, United States, 02453
        • MassResearch LLC.
    • Michigan
      • Detroit, Michigan, United States, 48202
        • Henry Ford Health
    • North Carolina
      • Asheville, North Carolina, United States, 28803
        • Mountain Area Health Educational Center ( MAHEC)
    • Texas
      • Austin, Texas, United States, 78731
        • Texas Diabetes and Endocrinology (TDE)
      • San Antonio, Texas, United States, 78229
        • Disease & Glandular Disease Clinic

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  1. Age at time of consent 18-75 years (inclusive)
  2. Clinical diagnosis, based on investigator assessment, of type 2 diabetes for at least 6 months at time of screening
  3. On current insulin regimen for at least 3 months prior to screening (i.e. basal-bolus, basal insulin only or premix)
  4. Basal-bolus (AID or non-AID pump & MDI) or premix users with A1C < 14% OR basal users on long or intermediate acting insulin only with A1C > 8.0% and < 14%
  5. Willing to use only the following types of U-100 insulin during the study: Humalog U-100, Novolog, Admelog, Kirsty, Fiasp, Lyumjev or their generic equivalents
  6. Deemed appropriate for pump therapy per Investigator's assessment considering previous history of severe hypoglycemic and hyperglycemic events, and other comorbidities
  7. If using noninsulin glucose-lowering medications (such as GLP-1 receptor agonist, SGLT2 inhibitor, or other) or weight-reduction medications, dose has been stable for 6-weeks prior to screening; and participant is willing to not change the dose unless required for safety purposes.
  8. Investigator has confidence that the participant can safely operate all study devices and can adhere to the protocol
  9. Willing to wear the system, including Pods, continuously throughout the study
  10. Willing and able to sign the Informed Consent Form (ICF)
  11. Able to read and understand English
  12. If of childbearing potential, willing and able to have pregnancy testing

Exclusion Criteria:

  1. Any medical condition, which in the opinion of the Investigator, would put the participant at an unacceptable safety risk. This may include untreated malignancy, unstable cardiac disease, unstable or end-stage renal disease, unstable proliferative retinopathy, unstable psychiatric conditions such as eating disorders, drug or alcohol abuse.
  2. Current or known history of coronary artery disease that is not stable with medical management, including unstable angina, or a history of myocardial infarction, percutaneous coronary intervention, or coronary artery bypass grafting within the 12 months prior to screening
  3. Any planned surgery during the study which could be considered major in the opinion of the Investigator
  4. History of more than 1 severe hypoglycemia in the past 6 months. Severe hypoglycemia is defined as an event that requires the assistance of another person due to altered consciousness, and requires another person to actively administer carbohydrate, glucagon, or other resuscitative actions
  5. History of more than 1 diabetic ketoacidosis (DKA) or hyperosmolar hyperglycemic state (HHS) in the past 6 months, unrelated to an intercurrent illness; kinked, dislodged, or occluded cannula; or initial diabetes diagnosis
  6. Unable to tolerate adhesive tape or has any unresolved skin condition that could impact sensor or pump placement
  7. Blood disorder or dyscrasia within 3 months prior to screening, which in the Investigator's opinion could interfere with determination of HbA1c
  8. Use of hydroxyurea
  9. Plans to receive blood transfusion over the course of the study
  10. Pregnant or lactating, or is of childbearing potential and not using an acceptable form of birth control (acceptable forms of contraception include abstinence, barrier methods such as condoms, hormonal contraceptives, intrauterine device, surgical sterilization such as tubal ligation or hysterectomy, or vasectomized partner); childbearing potential means that menstruation has started, and the participant is not surgically sterile or greater than 12 months post-menopausal).
  11. Has taken systemic corticosteroids (oral or injectable) within 4 weeks or has had a local steroid injection (intraarticular, epidural) within 1 week prior to screening or plans to take oral or injectable steroids during the study
  12. Participation in another clinical study using an investigational drug or device within 30-days or intends to participate in any other study during this study period
  13. Unable to follow clinical protocol for the duration of the study or is otherwise deemed unacceptable to participate in the study per the Investigator's clinical judgment
  14. Participant is an employee of Insulet, an Investigator or a member of Investigator's study team, or immediate family member of any of the aforementioned

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Experimental- Participants with Type 2 diabetes
The Omnipod M system will allow user to use a lower glucose target and improve systems glucose control

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percent of time in hypoglycemic range <70mg/dL
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Percent of time in hyperglycemic range >180 mg/dL
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Mean Glucose
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Percentage of time <54 mg/dL
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Percentage of time >250mg/dL
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Percentage of time >300mg/dL
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Percent of time between 70-180mg/dL
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Standard Deviation
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system (CGM)-measured glucose variability with the standard deviation (SD)
Comparing baseline metrics to the end of the treatment period (Day45)
Coefficient of Variation
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system (CGM)-measured glucose variability with the coefficient of variation (CV)
Comparing baseline metrics to the end of the treatment period (Day45)
Average total daily insulin (TDI)
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Average TDI/kg
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)
Change in weight
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
measures change in weight
Comparing baseline metrics to the end of the treatment period (Day45)
Patient reported outcomes
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Participant responses to various questionnaires related to the investigational device as well as managing diabetes
Comparing baseline metrics to the end of the treatment period (Day45)
4-hour post prandial glycemic metrics
Time Frame: Comparing baseline metrics to the end of the treatment period (Day45)
Glucose metric from study continuous glucose monitoring system
Comparing baseline metrics to the end of the treatment period (Day45)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

December 12, 2025

Primary Completion (Actual)

March 30, 2026

Study Completion (Actual)

March 30, 2026

Study Registration Dates

First Submitted

December 1, 2025

First Submitted That Met QC Criteria

December 1, 2025

First Posted (Actual)

December 11, 2025

Study Record Updates

Last Update Posted (Actual)

May 5, 2026

Last Update Submitted That Met QC Criteria

April 29, 2026

Last Verified

April 1, 2026

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Type 2 Diabetes Mellitus

Clinical Trials on Omnipod M system

Subscribe