Comparison of Two Seed Strand Implantation Techniques for Biliary Cancer

January 25, 2026 updated by: Peng, Zhaohong, The First Affiliated Hospital of Anhui Medical University

A Prospective, Randomized Controlled Trial Comparing Conventional Linear Versus Novel Spiral Iodine-125 Seed Strand Implantation Combined With Metallic Stent for Malignant Obstructive Jaundice

This study aimed to compare the safety and effectiveness of two different methods for fabricating and implanting Iodine-125 (^125^I) radioactive seed strands combined with a metal stent for treating malignant obstructive jaundice. The conventional method uses a straight seed strand placed between the stent and the bile duct wall. A novel technique was developed that uses a spiral-shaped seed strand placed inside the stent lumen.

Between January 2018 and February 2024, 105 patients were randomly assigned to two groups. Group A (59 patients) received the conventional straight strand, while Group B (46 patients) received the novel spiral strand. The study compared therapeutic efficacy, the incidence of intraoperative and postoperative complications, stent patency duration, and patient survival.

Both methods successfully improved liver function. However, the novel spiral technique (Group B) caused significantly fewer complications, such as bile leakage and peritonitis, compared to the conventional method (Group A). Importantly, patients in Group B also had longer stent patency (305 days vs. 277 days) and longer overall survival (345 days vs. 300 days).

In conclusion, the novel spiral seed strand implantation technique is a safer and more effective treatment option for malignant obstructive jaundice.

Study Overview

Detailed Description

Malignant obstructive jaundice often requires palliative drainage with self-expanding metallic stents. Combining stents with brachytherapy using Iodine-125 (^125^I) seed strands has been shown to prolong stent patency and patient survival compared to stenting alone. The conventional technique implants a linear seed strand between the stent and the bile duct wall, which is associated with risks of hemobilia, biliary fistula, and peritonitis due to the need for a larger puncture tract. This prospective, randomized controlled trial aimed to evaluate a novel, refined method involving a spiral-configured ^125^I seed strand implanted within the stent lumen, hypothesizing that it would reduce procedure-related complications while maintaining or improving therapeutic efficacy.

Study Design and Methods:

This was a single-center, prospective, randomized controlled trial. From January 2018 to February 2024, 105 patients with inoperable malignant obstructive jaundice were enrolled and randomly allocated into two groups.

Group A (Conventional, n=59): Received a straight ^125^I seed strand implanted between the metallic stent and the bile duct wall.

Group B (Novel, n=46): Received a spiral ^125^I seed strand implanted within the lumen of the metallic stent.

All patients first underwent percutaneous transhepatic biliary drainage (PTBD) for decompression, followed by the combined stent and seed strand (PTBSIS) procedure 3-7 days later.

Primary and Secondary Outcomes:

The primary endpoints were procedure-related complications (intraoperative and postoperative) and stent patency time. Secondary endpoints included technical success rate, improvement in liver function tests at one month, and overall patient survival. Complications assessed included nausea/vomiting, abdominal pain, hemobilia, vagal reflex, fever, biliary fistula, and biliary peritonitis.

Statistical Analysis:

Continuous data are presented as mean ± standard deviation or median (interquartile range). Categorical variables were compared using the Chi-square or Fisher's exact test. Stent patency and overall survival were analyzed using the Kaplan-Meier method with the log-rank test. A two-sided P-value < 0.05 was considered statistically significant. Analyses were performed using SPSS version 22.0.

Study Type

Interventional

Enrollment (Actual)

105

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Anhui
      • Hefei, Anhui, China, 230000
        • The First Affiliated Hospital of Anhui Medical University

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

Inclusion Criteria:

  • 1. Patients with a definitive diagnosis of Malignant Obstructive Jaundice (MOJ) confirmed by imaging (enhanced CT/MRCP), laboratory tests, and/or pathology.

    2. Assessed by a multidisciplinary team as not a candidate for curative surgical resection.

    3. No absolute contraindications for the combined implantation of a biliary metallic stent and an ^125^I seeds strand (e.g., severe coagulation dysfunction, significant renal impairment, or uncontrolled serious cardiovascular/cerebrovascular diseases).

    4. Willing and able to provide written informed consent.

Exclusion Criteria:

  1. Obstructive jaundice attributable to benign etiology.
  2. Presence of any absolute contraindication listed in the inclusion criteria.
  3. Life expectancy estimated to be less than three months.
  4. Unwillingness to participate in the study or provide informed consent.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Other
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Conventional linear implantation
In this group, participants received percutaneous transhepatic biliary stenting combined with a straight-configured ^125^I seed strand. The strand was fabricated by loading the prescribed number of ^125^I seeds into a 4F catheter, the ends of which were subsequently heat-sealed. During the procedure, after the deployment of a self-expanding metallic stent across the malignant stricture, the straight seed strand was implanted and fixed in the space between the outer wall of the stent and the bile duct wall to deliver localized brachytherapy.
This is a combined interventional radiology procedure for malignant obstructive jaundice. Under local anesthesia and fluoroscopic guidance, a self-expanding metallic biliary stent is percutaneously placed across the malignant stricture. Subsequently, a linear strand of Iodine-125 (^125^I) seeds, fabricated by sealing the prescribed number of seeds within a catheter, is implanted and fixed in the space between the outer wall of the stent and the bile duct wall. The ^125^I seeds provide continuous low-dose-rate brachytherapy to inhibit tumor ingrowth and prolong stent patency.
Other Names:
  • PTBSIS
Experimental: Novel spiral implantation
In this group, participants received percutaneous transhepatic biliary stenting combined with a spiral-configured ^125^I seed strand. The strand was fabricated by first preparing a linear catheter strand and then shaping it into a spiral configuration using boiling water. A slightly higher number of seeds were used to compensate for foreshortening. During the procedure, after stent deployment, the spiral seed strand was implanted and secured within the inner lumen of the metallic stent. This method was designed to reduce tract-related injury by utilizing a single, smaller working sheath and minimizing manipulation of the bile duct wall.
This is a combined interventional radiology procedure for malignant obstructive jaundice. Under local anesthesia and fluoroscopic guidance, a self-expanding metallic biliary stent is percutaneously placed across the malignant stricture. Subsequently, a spiral-configured strand of Iodine-125 (^125^I) seeds, fabricated by shaping a linear catheter strand with boiling water (using a slightly higher seed count to compensate for foreshortening), is implanted and secured within the inner lumen of the stent. The ^125^I seeds provide continuous low-dose-rate brachytherapy to inhibit tumor ingrowth and prolong stent patency. This method is designed to reduce tract-related injury by minimizing bile duct wall manipulation.
Other Names:
  • PTBSIS (novel)

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Stent Patency Time
Time Frame: From the date of randomization/stent placement until the date of documented stent re-obstruction or death from any cause, whichever occurs first, assessed up to 24 months.
The duration from the date of stent placement to the date of first documented stent re-obstruction (confirmed by imaging evidence of restenosis or occlusion). For patients who die without prior evidence of recurrent jaundice, the data will be censored at the date of death.
From the date of randomization/stent placement until the date of documented stent re-obstruction or death from any cause, whichever occurs first, assessed up to 24 months.
Overall Survival
Time Frame: From the date of randomization/stent placement until the date of death from any cause, assessed up to 24 months.
The time from the date of the stent placement procedure until the date of death from any cause. For patients who are alive at the end of the study, survival data will be censored at the date of the last follow-up contact.
From the date of randomization/stent placement until the date of death from any cause, assessed up to 24 months.

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Incidence of Procedure-Related Complications
Time Frame: Intraoperative period and up to 30 days after the procedure.
The composite rate of intraoperative and postoperative adverse events. Assessed complications include nausea/vomiting, abdominal pain, hemobilia, vagus reflex, fever, biliary fistula, and biliary peritonitis. Each complication will be documented as present or absent based on clinical and diagnostic criteria.
Intraoperative period and up to 30 days after the procedure.
Change in Serum Total Bilirubin (TBIL) Level
Time Frame: Baseline (pre-PTBSIS, after initial PTBD) and 1 month after the PTBSIS procedure.
The absolute change in serum total bilirubin concentration (measured in μmol/L) from the pre-procedure baseline (after initial PTBD drainage) to 1 month after the combined stent and seed strand implantation procedure.
Baseline (pre-PTBSIS, after initial PTBD) and 1 month after the PTBSIS procedure.
Change in Serum Alanine Aminotransferase (ALT) Level
Time Frame: Baseline (pre-PTBSIS, after initial PTBD) and 1 month after the PTBSIS procedure.
The absolute change in serum alanine aminotransferase activity (measured in U/L) from the pre-procedure baseline (after initial PTBD drainage) to 1 month after the combined stent and seed strand implantation procedure.
Baseline (pre-PTBSIS, after initial PTBD) and 1 month after the PTBSIS procedure.
Change in Serum Aspartate Aminotransferase (AST) Level
Time Frame: Baseline (pre-PTBSIS, after initial PTBD) and 1 month after the PTBSIS procedure.
The absolute change in serum aspartate aminotransferase activity (measured in U/L) from the pre-procedure baseline (after initial PTBD drainage) to 1 month after the combined stent and seed strand implantation procedure.
Baseline (pre-PTBSIS, after initial PTBD) and 1 month after the PTBSIS procedure.
Technical Success Rate
Time Frame: Assessed immediately upon completion of the stent and seed strand implantation procedure.
The proportion of procedures in which both the biliary metallic stent and the ^125^I seeds strand are successfully and precisely deployed at the intended target lesion site, as confirmed by immediate post-procedure fluoroscopy demonstrating unobstructed flow of contrast medium through the stent lumen into the duodenum.
Assessed immediately upon completion of the stent and seed strand implantation procedure.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 1, 2018

Primary Completion (Actual)

February 1, 2024

Study Completion (Actual)

February 1, 2024

Study Registration Dates

First Submitted

January 14, 2026

First Submitted That Met QC Criteria

January 25, 2026

First Posted (Actual)

February 2, 2026

Study Record Updates

Last Update Posted (Actual)

February 2, 2026

Last Update Submitted That Met QC Criteria

January 25, 2026

Last Verified

January 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • LLSC20221301

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Clinical Trials on Malignant Obstructive Jaundice

Subscribe