Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

The Protective Role of the Nose During Acute Exposure to Passive Smoking.

13. listopadu 2013 aktualizováno: Hellenic Anticancer Society
The aim of this study was to compare the acute effects of second hand smoke exposure between nasal and oral breathing and to assess the potential protective role of the nose during acute exposure, in exposure conditions similar to those within a bar where smoking is permitted.

Přehled studie

Postavení

Dokončeno

Detailní popis

Analysis of the laboratory testing:

The measurement of NO for the respiratory tract was performed with a Ecomedics CLD 88spNO analyzer as follows: the examinee performed tidal breathing with a closed nose, through a special mouthpiece and then took a deep breath and exhale steadily with a flow of 50ml/sec. After 3 attempts, during which we obtained an exhaled NO measurement each time, until we obtained a reliability index CV <10%.

For the oscillometry (IOS) of the respiratory tract the Master Screen IOS VIASYS was used, the examinee breathed quietly through the mouthpiece with his/her nose closed for a period of 1 minute. In this way we measured the impedance Z at 5 Hz, the resistance to 5,10,20 Hz respectively, the reactance in 5,10,20 Hz respectively, the central and peripheral airway resistance and resonant frequency.

Rhinomanometry was done by the Master Screen IOS VIASYS system, the examinee breathed calmly through the examined nostril, while the other was closed, 5 breaths per attempt were performed. After 3 attempts for each nostril, we assessed the average inspiratory resistance for each nostril separately.

The plethysmography took place on the Master Screen Body of VIASYS, the door of the Body was closed as well as all the doors of the room and without the presence of motion in the test room. The subject performed calm breaths with a closed nose, through the mouthpiece and then took a deep breath, followed by deep exhalation. At the end of the effort we had values for the total lung capacity (TLC), residual volume (RV), airway resistance (R), vital capacity (VC), the functional residual capacity (FRC), Exhaled residual volume (ERV) and the ratio RV / TLC. This was repeated 3 times and one was selected to be the most representative.

The P.100 was performed through the Master Screen Body of VIASYS with the door of the Body Box opened. The volunteer was performing calm breaths with a closed nose, through the mouthpiece, during which a shutter blocked the flow. The obtained value of the pressure was the one that developed in the first second of inhalation with the shutter down is noted. This repeated 3 times and one selected to be the most representative.

Spirometry and the flow-volume curve were assessed with a Master Screen Body of VIASYS with the door of the Body Box opened as follows: The subject performed tidal breathing with a closed nose, through the mouthpiece, and then took a sharp deep breath, which was followed by sharp deep exhalation, and the test ended with deep inhalation. At the end of the effort we had values for forced vital capacity (FVC), the violent expiratory the first volume 1 (FEV1), the ratio FVC/FEV1%, peak expiratory flow (PEF) and mesoexpiratory flow in peripheral airways than 25% to 75% of vital capacity. This was repeated 3 times and one was selected to be the most representative.

The assessment of the type of breathing during exposure to secondhand smoke was performed through the VIASYS Respitrace. The protocol was as follows: The volunteer breathed calmly over 20 times with the mouth closed and once with a closed nose, while wearing two rubber bands, one on the chest and one to the abdomen, which incorporates electrodes. The waveform of the breath in the thorax, abdomen and the average of these was recorded in real time. Also, for every breath we had values for the inspiratory time, expiratory time, total time, the participation rate of the chest, the participation rate of the ventricle, the peak inspiratory flow (Pif), the mean inspiratory flow (Mif), and the flow-volume curve and the analysis chart of each breath in the thoracic and abdominal component.

Typ studie

Intervenční

Zápis (Aktuální)

21

Fáze

  • Fáze 1

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Attiki
      • Athens, Attiki, Řecko
        • Hellenic Anticancer Society

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

18 let až 45 let (Dospělý)

Přijímá zdravé dobrovolníky

Ano

Pohlaví způsobilá ke studiu

Všechno

Popis

Inclusion Criteria:

  • healthy volunteer adults non-smokers

Exclusion Criteria:

  • < 18 years old
  • Recent or chronic disease of the upper or lower respiratory system.
  • Current pregnancy
  • Breastfeeding women

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Prevence
  • Přidělení: Nerandomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Singl

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Experimentální: nasal breathing

At the time that the exposure took place with nasal breathing, the study was as follows:

Before the exposure: rhinomanometry, IOS , FeNO , spirometry, plethysmography, P.100.

Exposure to second hand smoking:Each volunteer was exposed to secondhand smoking twice, for 20 minutes, once with nasal breathing and once with oral breathing, with 3 days interval and in random sequence.

After the exposure: rhinomanometry, IOS , FeNO , spirometry,plethysmography , P.100.

The duration of the exposure to second hand smoke both days was for 20 minutes within a 250mgr/m3 concentration box room. A smoking machine was used, which mimics the smoker (up to 6 breaths per minute in tobacco volume 80ml for each inhalation). The exposure was sometimes with closed mouth and others with closed nose in random sequence.
Experimentální: oral breathing

At the time that the exposure took place with oral breathing, the study was as follows:

Before the exposure: IOS, exhaled nitric oxide (FeNO), spirometry, plethysmography and P.100.

Exposure to second hand smoking: each volunteer was exposed to secondhand smoking twice, for 20 minutes, once with nasal breathing and once with oral breathing, with 3 days interval and in random sequence.

After the exposure: IOS, FeNO, spirometry,plethysmography and P.100.

The duration of the exposure to second hand smoke both days was for 20 minutes within a 250mgr/m3 concentration box room. A smoking machine was used, which mimics the smoker (up to 6 breaths per minute in tobacco volume 80ml for each inhalation). The exposure was sometimes with closed mouth and others with closed nose in random sequence.

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
exhaled nitric oxide (FeNO) for the respiratory tract
Časové okno: before exposure (Baseline) and after exposure with a 30 minutes interval
To compare the changes between the two types of breathing
before exposure (Baseline) and after exposure with a 30 minutes interval
plethysmography
Časové okno: before exposure (Baseline) and after exposure with a 30 minutes interval
plethysmography take place both at oral and nasal breathing twice before and after intervention.
before exposure (Baseline) and after exposure with a 30 minutes interval

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Eye or nose irritation
Časové okno: during the exposure to second hand smoke
During the exposure to second hand smoke that lasted 20 minutes the examinee had his /her mouth closed and filled in an evaluation Questionnaire about eye or nose irritation.
during the exposure to second hand smoke

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Vyšetřovatelé

  • Studijní židle: Panagiotis K Behrakis, Professor, National and Kapodistrian University of Athens
  • Vrchní vyšetřovatel: Palagia M Karas, MD, National and Kapodistrian University of Athens

Publikace a užitečné odkazy

Osoba odpovědná za zadávání informací o studiu tyto publikace poskytuje dobrovolně. Mohou se týkat čehokoli, co souvisí se studiem.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia

1. srpna 2011

Primární dokončení (Aktuální)

1. února 2013

Dokončení studie (Aktuální)

1. července 2013

Termíny zápisu do studia

První předloženo

28. října 2013

První předloženo, které splnilo kritéria kontroly kvality

13. listopadu 2013

První zveřejněno (Odhad)

20. listopadu 2013

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Odhad)

20. listopadu 2013

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

13. listopadu 2013

Naposledy ověřeno

1. listopadu 2013

Více informací

Termíny související s touto studií

Další identifikační čísla studie

  • 6322/6.3.13

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na Second Hand Smoke Exposure

3
Předplatit