The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required.

Studieoversigt

Detaljeret beskrivelse

The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required. The investigators want to evaluate the technique of placement of the double-lumen endobronchial tube (DLT) using an included stylet that has been radically bent (ZU-bend) as compared to a commercial GlideRite stylet with the GlideScope and direct laryngoscopy using the Macintosh laryngoscope. A double-lumen endobronchial tube (DLT) is a breathing tube utilized to manage the airway when lung separation is needed for a surgical procedure. The investigator wants to evaluate how long it takes for successful placement of the double-lumen endobronchial tube (DLT) and assess the difficulty of the procedure experienced by the physician performing the intubation.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

19

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Georgia
      • Atlanta, Georgia, Forenede Stater, 30322
        • Emory University Hospital
      • Atlanta, Georgia, Forenede Stater, 30308
        • Emory University Hospital Midtown

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  1. Male and female patients requiring a double-lumen endobronchial tube placement for surgery at Emory University Hospital or Emory University Hospital Midtown
  2. Patients willing and able to provide written informed consent

Exclusion Criteria:

  1. Patients in whom a previously difficult airway manipulation was recorded on an anesthetic record
  2. Lung transplantation procedures, as underlying pulmonary disorder that will confound the SpO2 (peripheral capillary oxygen saturation) metric
  3. Any patient who is receiving anticoagulants in excess of a daily aspirin, patients with an International Normalized Ratio or INR >1
  4. Patients in whom one lung ventilation or placement of a double-lumen endobronchial tube is contraindicated
  5. Patients who require a rapid-sequence intubation
  6. Patients undergoing emergency procedures

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Sundhedstjenesteforskning
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: ZU-bend stylet with GlideScope technique
Subjects scheduled for thoracic surgery in which the surgeon requests lung isolation will undergo laryngoscopy and intubation using the ZU-bend with the GlideScope technique of a double lumen endobronchial tube (DLT) placement as part of the anesthesia procedure prior to surgery.
Laryngoscopy and intubation after induction of anesthesia will be done using the GlideScope and the ZU-bend stylet. The ZU-bend is a specific shaping technique of the intubating stylet that is closely related to the GlideScope blade curvature. Zu-bend stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique. The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation. GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Aktiv komparator: GlideScope with the GlideRite stylet
Subjects scheduled for thoracic surgery in which the surgeon requests lung isolation will undergo laryngoscopy and intubation using the GlideScope with the GlideRite stylet for placement of a double lumen endobronchial tube (DLT) as part of the anesthesia procedure prior to surgery.
Laryngoscopy and intubation after induction of anesthesia will be done using the the GlideScope technique. The GlideScope is a video laryngoscope that provides a real-time view of the airway and tube placement during intubation. GlideScope is removed after DLT is in the trachea, and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Laryngoscopy and intubation after induction of anesthesia will be done with the GlideScope using the GlideRite stylet. The GlideRite stylet is specifically designed to work with the GlideScope and provides the necessary rigidity and curvature to an otherwise flexible tube. GlideRite stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, GlideScope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.
Aktiv komparator: Macintosh blade and a regular DLT stylet
Subjects scheduled for thoracic surgery in which the surgeon requests lung isolation will undergo laryngoscopy and intubation using the direct laryngoscopy technique with the Macintosh blade and a regular double lumen endobronchial tube (DLT) stylet as part of the anesthesia procedure prior to surgery.
Direct laryngoscopy and intubation after induction of anesthesia will be done with the Macintosh blade and a regular double-lumen endobronchial tube (DLT) stylet. The Macintosh blade is used to facilitate visualization of the larynx during double or single lumen endobronchial tube placement. After intubation the Macintosh laryngoscope is removed and the confirmation of the successful placement of the double-lumen endobronchial tube in done in the standard fashion.
Andre navne:
  • Laryngoscope blade
Direct laryngoscopy and intubation after induction of anesthesia will be done with a regular double-lumen endobronchial tube (DLT) stylet and the Macintosh blade. The DLT stylet is withdrawn as a part of placement procedure during the DLT advancement. Thereafter, Macintosh laryngoscope is removed and placement of the double-lumen endobronchial tube is verified with capnography and fiberoptic bronchoscopy in the usual manner.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Mean Time to Place the Double-lumen Endobronchial Tube
Tidsramme: during laryngoscope placement, up to 120 seconds
The time taken for successful intubation will be recorded by the anesthetist. The total duration from the time the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2), an average of 120 seconds, will be recorded in seconds. A higher duration noted is indicative of a longer time taken for successful intubation. 0 seconds (laryngoscope at patient's lips), (first End-tidal CO2 (EtCO2) detection)
during laryngoscope placement, up to 120 seconds

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Success Rate of First Endobronchial Intubation Attempt
Tidsramme: during laryngoscope placement, up to 120 seconds
The rate of first intubation attempt success will be recorded by the anesthetist. A successful first attempt intubation is when the double-lumen endobronchial tube is placed during the initial laryngoscopy within 120 seconds. The average time for successful intubation is 120 seconds, which is the time from when the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2). Higher numbers of successful first attempt intubations indicate better rates of success of first endobronchial intubation attempts .
during laryngoscope placement, up to 120 seconds
Assessment of Difficulty of Intubation
Tidsramme: during laryngoscope placement, up to 120 seconds
The ease of successful placement of the double-lumen endobronchial tube (DLT) will be assessed by the anesthetist's responses to a multi-question form which includes the following items that are scored; overall ease of intubation, laryngoscope insertion, glottic view, double-lumen endobronchial tube (DLT) delivery and placement. The subjective scores range from 0-10; where 0=worst, 10=best. The average time for successful intubation is 120 seconds, which is the time from when the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2).
during laryngoscope placement, up to 120 seconds
Number of Cases With Complications
Tidsramme: during laryngoscope placement, up to 120 seconds
Number of cases with complications during intubation will be will be assessed by the anesthetist's responses to a multi-question form which includes the following items; blood on device, SpO2 (peripheral capillary oxygen saturation) <96%, lip and dental trauma and double-lumen endobronchial tube (DLT) cuff rupture. The responses are recorded as Yes or No for each item. A 'yes' response indicates a complication. The average time for successful intubation is 120 seconds, which is the time from when the laryngoscope is placed at the patient's lips to the first detection of End-tidal CO2 (EtCO2).
during laryngoscope placement, up to 120 seconds
Number of Cases of Voice Change
Tidsramme: Up to 60 minutes after extubation
Any voice change in the patient after extubation will be assessed in the Post-Operative Admission Unit (PACU) by asking the patient if any change in voice is experienced (Yes/No). The subjective answer given by the patient will be recorded. The average time for the patient to sufficiently recover to respond is expected to be 60 minutes after extubation.
Up to 60 minutes after extubation
Throat Pain
Tidsramme: Up to 60 minutes after extubation
Any voice change in the patient after extubation will be assessed in the Post-Operative Admission Unit (PACU) by recording the patient's response to the degree of pain experienced. An analog pain scale will be used for scoring where: 0= no pain and 10= severe pain. The average time for the patient to sufficiently recover to respond is expected to be 60 minutes after extubation.
Up to 60 minutes after extubation

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Igor Zhukov, MD, Emory University

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. juli 2015

Primær færdiggørelse (Faktiske)

27. juli 2017

Studieafslutning (Faktiske)

27. juli 2017

Datoer for studieregistrering

Først indsendt

9. juli 2015

Først indsendt, der opfyldte QC-kriterier

10. juli 2015

Først opslået (Skøn)

13. juli 2015

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

27. juli 2018

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

20. juni 2018

Sidst verificeret

1. juni 2018

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • IRB00081067

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Luftvejssygelighed

Kliniske forsøg med ZU-bend stylet

3
Abonner